Does a trochanteric lag screw improve fixation of vertically oriented femoral neck fractures? A biomechanical analysis in cadaveric bone

被引:55
|
作者
Hawks, Michael A. [1 ]
Kim, Hyunchul [2 ]
Strauss, Joseph E. [1 ]
Oliphant, Bryant W. [1 ]
Golden, Robert D. [1 ]
Hsieh, Adam H. [2 ]
Nascone, Jason W. [1 ]
O'Toole, Robert V. [1 ]
机构
[1] Univ Maryland, Sch Med, R Adams Cowley Shock Trauma Ctr, Dept Orthopaed, Baltimore, MD 21201 USA
[2] Univ Maryland, Fischell Dept Bioengn, Orthopaed Mechanobiol Lab, College Pk, MD 20742 USA
关键词
Trochanteric lag screw; Inverted triangle construct; Femoral neck fracture;
D O I
10.1016/j.clinbiomech.2013.08.007
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background: We assessed the biomechanical performances of a trochanteric lag screw construct and a traditional inverted triangle construct in the treatment of simulated Pauwels type 3 femoral neck fractures. Methods: An inverted triangle construct (three 7.3-mm cannulated screws placed in inverted triangle orientation) and a trochanteric lag screw construct (two 7.3-mm cannulated screws placed across the superior portion of the femoral neck and one 4.5-mm lag screw placed perpendicular to the fracture in superolateral to inferomedial orientation) were tested in nine matched pairs of non-osteoporotic human cadaveric femora. We used a previously described vertically oriented femoral neck fracture model and testing protocol that incrementally loaded the constructs along the mechanical axis of the femur to 1400 N. Specimens that survived incremental loading underwent cyclic loading. Apparent construct stiffness, force at 3 mm of displacement, and survival of incremental loading were recorded. Findings: The trochanteric lag screw group had a 70% increase in stiffness (261 N/mm [29 standard deviation] versus 153 N/mm [16 standard deviation]; P = 0.026) and a 43% increase in force required for displacement (620 N versus 435 N; P = 0.018) compared with the inverted triangle group. One trochanteric lag screw and no inverted triangle specimen survived incremental loading. Interpretation: A trochanteric lag screw construct applied to vertically oriented femoral neck fractures provides marked improvement in mechanical performance compared with the inverted triangle construct. (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:886 / 891
页数:6
相关论文
共 32 条
  • [1] Vertically Oriented Femoral Neck Fractures: A Biomechanical Comparison of 3 Fixation Constructs
    Johnson, Joey P.
    Borenstein, Todd R.
    Waryasz, Gregory R.
    Klinge, Stephen A.
    McClure, Philip K.
    Chambers, Alison B.
    Hayda, Roman A.
    Born, Christopher T.
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2017, 31 (07) : 363 - 368
  • [2] Vertically oriented femoral neck fractures: Mechanical analysis of four fixation techniques
    Aminian, Arash
    Gao, Fan
    Fedoriw, Wasyl W.
    Zhang, Li-Qun
    Kalainov, David M.
    Merk, Bradley R.
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2007, 21 (08) : 544 - 548
  • [3] Does the angle between dynamic hip screw and anti-rotation screw affect the outcome of vertically oriented femoral neck fractures? A biomechanical analysis and clinical results
    Xian, Hang
    Cheng, Weike
    Xie, Wei
    Wang, Lei
    Luo, Deqing
    Liu, Hui
    Lian, Kejian
    Lin, Dasheng
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2024, 55 (03):
  • [4] Biomechanical analysis of the closed reduction internal fixation with cannulated screw of femoral neck fractures
    Wang, Jian-Guang
    Wu, Jun-Xian
    Li, Yu-Min
    Xu, You-Yin
    MEDICINE, 2021, 100 (08) : E24834
  • [5] Biomechanical evaluation of the expansive cannulated screw for fixation of femoral neck fractures
    Zhang, Yang
    Tian, Li
    Yan, Yabo
    Sang, Hongxun
    Ma, Zhensheng
    Jie, Qiang
    Lei, Wei
    Wu, Zixiang
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2011, 42 (11): : 1372 - 1376
  • [6] Is bone-cement augmentation of screw-anchor fixation systems superior in unstable femoral neck fractures? A biomechanical cadaveric study
    Knobe, Matthias
    Bettag, Sebastian
    Kammerlander, Christian
    Altgassen, Simon
    Maier, Klaus-Juergen
    Nebelung, Sven
    Prescher, Andreas
    Horst, Klemens
    Pishnamaz, Miguel
    Herren, Christian
    Mundt, Marion
    Stoffel, Marcus
    Markert, Bernd
    Gueorguiev, Boyko
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2019, 50 (02): : 292 - 300
  • [7] Hybrid screw fixation for femoral neck fractures: Does it prevent mechanical failure?
    Cuellar, Derly O., III
    Velez, Dencel A. Garcia
    Bledsoe, Gary
    Watson, J. Tracy
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2022, 53 (08): : 2839 - 2845
  • [8] Screw-blade fixation systems in Pauwels three femoral neck fractures: a biomechanical evaluation
    Matthias Knobe
    Simon Altgassen
    Klaus-Jürgen Maier
    Gertraud Gradl-Dietsch
    Chris Kaczmarek
    Sven Nebelung
    Kajetan Klos
    Bong-Sung Kim
    Boyko Gueorguiev
    Klemens Horst
    Benjamin Buecking
    International Orthopaedics, 2018, 42 : 409 - 418
  • [9] Screw-blade fixation systems in Pauwels three femoral neck fractures: a biomechanical evaluation
    Knobe, Matthias
    Altgassen, Simon
    Maier, Klaus-Jurgen
    Gradl-Dietsch, Gertraud
    Kaczmarek, Chris
    Nebelung, Sven
    Klos, Kajetan
    Kim, Bong-Sung
    Gueorguiev, Boyko
    Horst, Klemens
    Buecking, Benjamin
    INTERNATIONAL ORTHOPAEDICS, 2018, 42 (02) : 409 - 418
  • [10] Comparison of augmentation effects of medial buttress plate versus trochanteric lag screw in the cannulated screw fixation of Pauwels type III femoral neck fractures: A retrospective clinical study
    Shen, Longxiang
    Ye, Kai
    An, Zhiquan
    ACTA ORTHOPAEDICA ET TRAUMATOLOGICA TURCICA, 2023, 57 (05) : 250 - 257