A New PET Scanner with Semiconductor Detectors Enables Better Identification of Intratumoral Inhomogeneity

被引:29
作者
Shiga, Tohru [1 ]
Morimoto, Yuichi [2 ]
Kubo, Naoki [3 ]
Katoh, Norio [4 ]
Katoh, Chietsugu [3 ]
Takeuchi, Wataru [2 ]
Usui, Reiko [1 ]
Hirata, Kenji [1 ]
Kojima, Shinichi [2 ]
Umegaki, Kikuo [2 ]
Shirato, Hiroki [4 ]
Tamaki, Nagara [1 ]
机构
[1] Hokkaido Univ, Sch Med, Dept Nucl Med, Sapporo, Hokkaido 060, Japan
[2] Hitachi Ltd, Cent Res Lab, Ibaraki, Japan
[3] Hokkaido Univ, Fac Hlth Sci, Sapporo, Hokkaido 060, Japan
[4] Hokkaido Univ, Sch Med, Dept Radiol, Sapporo, Hokkaido 060, Japan
关键词
oncology; PET; semiconductor; intratumoral heterogeneity; MODULATED RADIATION-THERAPY; GRANULATION TISSUES; EMISSION-TOMOGRAPHY; CANCER-CELLS; PERFORMANCE; HEAD; RADIOTHERAPY; FLUORODEOXYGLUCOSE; MACROPHAGES; SYSTEM;
D O I
10.2967/jnumed.108.054833
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
An autoradiography method revealed intratumoral inhomogeneity in various solid tumors. It is becoming increasingly important to estimate intratumoral inhomogeneity. However, with low spatial resolution and high scatter noise, it is difficult to detect intratumoral inhomogeneity in clinical settings. We developed a new PET system with CdTe semiconductor detectors to provide images with high spatial resolution and low scatter noise. Both phantom images and patients' images were analyzed to evaluate intratumoral inhomogeneity. Methods: This study was performed with a cold spot phantom that had 6-mm-diameter cold sphenoid defects, a dual-cylinder phantom with an adjusted concentration of 1:2, and an "H"-shaped hot phantom. These were surrounded with water. Phantom images and F-18-FDG PET images of patients with nasopharyngeal cancer were compared with conventional bismuth germanate PET images. Profile curves for the phantoms were measured as peak-to-valley ratios to define contrast. Intratumoral inhomogeneity and tumor edge sharpness were evaluated on the images of the patients. Results: The contrast obtained with the semiconductor PET scanner (1.53) was 28% higher than that obtained with the conventional scanner (1.20) for the 6-mm-diameter cold sphenoid phantom. The contrast obtained with the semiconductor PET scanner (1.43) was 27% higher than that obtained with the conventional scanner (1.13) for the dual-cylinder phantom. Similarly, the 2-mm cold region between 1-mm hot rods was identified only by the new PET scanner and not by the conventional scanner. The new PET scanner identified intratumoral inhomogeneity in more detail than the conventional scanner in 6 of 10 patients. The tumor edge was sharper on the images obtained with the new PET scanner than on those obtained with the conventional scanner. Conclusion: These phantom and clinical studies suggested that this new PET scanner has the potential for better identification of intratumoral inhomogeneity, probably because of its high spatial resolution and low scatter noise.
引用
收藏
页码:148 / 155
页数:8
相关论文
共 28 条
[1]  
BROWN RS, 1995, J NUCL MED, V36, P1854
[2]   HEPATOBLASTOMA - RADIOLOGIC-PATHOLOGICAL CORRELATION IN 50 CASES [J].
DACHMAN, AH ;
PAKTER, RL ;
ROS, PR ;
FISHMAN, EK ;
GOODMAN, ZD ;
LICHTENSTEIN, JE .
RADIOLOGY, 1987, 164 (01) :15-19
[3]  
Daube-Witherspoon ME, 2002, J NUCL MED, V43, P1398
[4]   NEMA NU2-2001 guided performance evaluation of four siemens ECAT PET scanners [J].
Herzog, H ;
Tellmann, L ;
Hocke, C ;
Pietrzyk, U ;
Casey, ME ;
Kuwert, T .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2004, 51 (05) :2662-2669
[5]  
Ketchum LE, 1998, J NUCL MED, V39, p15N
[6]   Applicability of a high-resolution small semiconductor gamma camera to small animal imaging [J].
Kiyono, Yasushi ;
Kuge, Yuji ;
Katada, Yumiko ;
Kawashima, Hidekazu ;
Magata, Yasuhiro ;
Saji, Hideo .
NUCLEAR MEDICINE COMMUNICATIONS, 2007, 28 (09) :736-741
[7]   Evaluating performance of a pixel array semiconductor SPECT system for small animal imaging [J].
Kubo, N ;
Zhao, S ;
Fujiki, Y ;
Kinda, A ;
Motomura, N ;
Katoh, C ;
Shiga, T ;
Kawashima, H ;
Kuge, Y ;
Tamaki, N .
ANNALS OF NUCLEAR MEDICINE, 2005, 19 (07) :633-639
[8]   Validation of left ventricular function from gated single photon computed emission tomography by using a scintillator-photodiode camera: a dynamic myocardial phantom study [J].
Kubo, N ;
Mabuchi, M ;
Katoh, C ;
Arai, H ;
Morita, K ;
Tsukamoto, E ;
Morita, Y ;
Tamaki, N .
NUCLEAR MEDICINE COMMUNICATIONS, 2002, 23 (07) :639-643
[9]  
KUBOTA R, 1992, J NUCL MED, V33, P1972
[10]  
KUBOTA R, 1994, J NUCL MED, V35, P1067