Impact of plan parameters on the dosimetric accuracy of volumetric modulated arc therapy

被引:216
|
作者
Masi, Laura [1 ]
Doro, Raffaela [1 ]
Favuzza, Virginia [1 ]
Cipressi, Samantha [1 ]
Livi, Lorenzo [2 ]
机构
[1] Dept Med Phys & Radiat Oncol IFCA, I-50139 Florence, Italy
[2] Univ Florence, Dept Radiat Oncol, I-50134 Florence, Italy
关键词
VMAT; planning parameters; QUALITY-ASSURANCE; RADIATION-THERAPY; IMRT; DELIVERY; VMAT; COMPLEXITY; NUMBER;
D O I
10.1118/1.4810969
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To evaluate the effect of plan parameters on volumetric modulated arc therapy (VMAT) dosimetric accuracy, together with the possibility of scoring plan complexity. Methods: 142 clinical VMAT plans initially optimized using a 4 degrees control point (CP) separation were evaluated. All plans were delivered by a 6 MV Linac to a biplanar diode array for patient-specific quality assurance (QA). Local Gamma index analysis (3%, 3 mm and 2%, 2 mm) enabled the comparison between delivered and calculated dose. The following parameters were considered for each plan: average leaf travel (LT), modulation complexity score applied to VMAT (MCSv), MU value, and a multiplicative combination of LT and MCSv (LTMCS). Pearson's correlation analysis was performed between Gamma passing rates and each parameter. The effects of CP angular separation on VMAT dosimetric accuracy were also analyzed by focusing on plans with high LT values. Forty out of 142 plans with LT above 350 mm were further optimized using a finer angle spacing (3 degrees or 2 degrees) and Gamma analysis was performed. The average Gamma passing rates obtained at 4 degrees and at 3 degrees/2 degrees sampling were compared. A further correlation analysis between all parameters and the Gamma pass-rates was performed on 142 plans, but including the newly optimized 40 plans (CP every 3 degrees or 2 degrees) in place of the old ones (CP every 4 degrees). Results: A moderate significant (p < 0.05) correlation between each examined parameter and Gamma passing rates was observed for the original 142 plans at 4 degrees CP discretization. A negative correlation was found for LT with Pearson's r absolute values above 0.6, suggesting that a lower dosimetric accuracy may be expected for higher LT values when a 4 degrees CP sampling is used. A positive correlation was observed for MCSv and LTMCS with r values above 0.5. In order to score plan complexity, threshold values of LTMCS were defined. The average Gamma passing rates were significantly higher for the plans created using the finer CP spacing (3 degrees/2 degrees) compared to the plans optimized using the standard 4 degrees spacing (Student t-test p < 0.05). The correlation between LT and passing rates was strongly diminished when plans with finer angular separations were considered, yielding Pearson's r absolute values below 0.45. Conclusions: At 4 degrees CP sampling, LT, MCSv, and LTMCS were found to be significantly correlated with VMAT dosimetric accuracy, expressed as Gamma pass-rates. These parameters were found to be possible candidates for scoring plan complexity using threshold values. A finer CP separation (3 degrees/2 degrees) led to a significant increase in dosimetric accuracy for plans with high leaf travel values, and to a decrease in correlation between LT and Gamma passing rates. These results indicated that the influence of LT on VMAT dosimetric accuracy can be controlled by reducing CP separation. CP spacing for all plans requiring large leaf motion should not exceed 3 degrees. The reported data were integrated to optimize our clinical workflow for plan creation, optimization, selection among rival plans, and patient-specific QA of VMAT treatments. (C) 2013 American Association of Physicists in Medicine.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Impact of Plan Complexity On the Delivery Accuracy and Dosimetric Accuracy of Volumetric-Modulated Arc Therapy
    Li, G.
    Li, Y.
    Wang, Q.
    Xiao, J.
    Bai, S.
    MEDICAL PHYSICS, 2017, 44 (06) : 2892 - 2892
  • [2] Modulation indices and plan delivery accuracy of volumetric modulated arc therapy
    Park, Jong Min
    Kim, Jung-in
    Park, So-Yeon
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2019, 20 (06): : 12 - 22
  • [3] Dosimetric Impact of Treatment Couch on Volumetric Modulated Arc Therapy (VMAT)
    Ye, J.
    Liu, H.
    Kim, J. J.
    Deng, J.
    Chen, Z.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2013, 87 (02): : S708 - S709
  • [4] Dosimetric impact of volumetric modulated arc therapy for nasopharyngeal cancer treatment
    Franzese, Ciro
    Fogliata, Antonella
    Loi, Mauro
    Badalamenti, Marco
    Franceschini, Davide
    Comito, Tiziana
    Cozzi, Luca
    Reggiori, Giacomo
    Tomatis, Stefano
    Scorsetti, Marta
    REPORTS OF PRACTICAL ONCOLOGY AND RADIOTHERAPY, 2021, 26 (01) : 101 - 110
  • [5] The Impact of Plan Complexity Parameters On the Plan Quality and Deliverability of Volumetric Modulated Arc Therapy with Canonical Correlation Analysis
    Jin, X.
    Yi, J.
    Xie, C.
    MEDICAL PHYSICS, 2016, 43 (06) : 3372 - 3372
  • [6] Impact of beam complexity on plan delivery accuracy verification of a transmission detector in volumetric modulated arc therapy
    Radici, Lorenzo
    Petrucci, Edoardo
    Borca, Valeria Casanova
    Cante, Domenico
    Piva, Cristina
    Pasquino, Massimo
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2024, 122
  • [7] Impact of machines on plan quality: volumetric modulated arc therapy and intensity modulated radiation therapy
    Clemente, S.
    Cozzolino, M.
    Oliviero, C.
    Fiorentino, A.
    Chiumento, C.
    Fusco, V.
    CLINICAL & TRANSLATIONAL ONCOLOGY, 2014, 16 (02): : 141 - 146
  • [8] Impact of machines on plan quality: volumetric modulated arc therapy and intensity modulated radiation therapy
    S. Clemente
    M. Cozzolino
    C. Oliviero
    A. Fiorentino
    C. Chiumento
    V. Fusco
    Clinical and Translational Oncology, 2014, 16 : 141 - 146
  • [9] DOSIMETRIC VERIFICATION OF RAPIDARC™ VOLUMETRIC MODULATED ARC THERAPY
    Medin, J.
    Kjaer-Kristoffersen, F.
    Ceberg, S.
    Back, S.
    Gustavsson, H.
    Archambault, Y.
    Bocanek, J.
    Cozzi, L.
    Eberhard, V.
    Gomola, I.
    Wiberg, I.
    Korreman, S.
    RADIOTHERAPY AND ONCOLOGY, 2008, 88 : S47 - S48
  • [10] Dosimetric impact of baseline drift in volumetric modulated arc therapy with breath holding
    Ono, Shunsuke
    Ueda, Yoshihiro
    Inui, Shoki
    Isono, Masaru
    Ohira, Shingo
    Murata, Seiya
    Miyazaki, Masayoshi
    Teshima, Teruki
    REPORTS OF PRACTICAL ONCOLOGY AND RADIOTHERAPY, 2020, 25 (05) : 703 - 708