Comparison of the Polar S810i monitor and the ECG for the analysis of heart rate variability in the time and frequency domains

被引:176
作者
Vanderlei, L. C. M. [1 ]
Silva, R. A. [2 ]
Pastre, C. M. [1 ]
Azevedo, F. M. [3 ]
Godoy, M. F. [4 ]
机构
[1] UNESP, FCT, Dept Fisioterapia, BR-19060900 Presidente Prudente, SP, Brazil
[2] UNESP, FCT, Curso Especializacao Fisioterapia, BR-19060900 Presidente Prudente, SP, Brazil
[3] UNESP, FCT, Lab Fisioterapia Aplicada Movimento Humano, BR-19060900 Presidente Prudente, SP, Brazil
[4] Fac Med Sao Jose do Rio Preto, Dept Cardiol & Cirurgia Cardiovasc, Sao Jose Do Rio Preto, SP, Brazil
关键词
Heart rate variability; Autonomic nervous system; Exercise; Spectral analysis; ECG; Polar S810i monitor;
D O I
10.1590/S0100-879X2008005000039
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
The aim of the present study was to compare heart rate variability (HRV) at rest and during exercise using a temporal series obtained with the Polar S810i monitor and a signal from a LYNX (R) signal conditioner (BIO EMG 1000 model) with a channel configured for the acquisition of ECG signals. Fifteen healthy subjects aged 20.9 +/- 1.4 years were analyzed. The subjects remained at rest for 20 min and performed exercise for another 20 min with the workload selected to achieve 60% of submaximal heart rate. RR series were obtained for each individual with a Polar S810i instrument and with an ECG analyzed with a biological signal conditioner. The HRV indices (rMSSD, pNN50, LFnu, HFnu, and LF/HF) were calculated after signal processing and analysis. The unpaired Student t-test and intraclass correlation coefficient were used for data analysis. No statistically significant differences were observed when comparing the values analyzed by means of the two devices for HRV at rest and during exercise. The intraclass correlation coefficient demonstrated satisfactory correlation between the values obtained by the devices at rest (pNN50 = 0.994; rMSSD = 0.995; LFnu = 0.978; HFnu = 0.978; LF/HF = 0.982) and during exercise (pNN50 = 0.869; rMSSD = 0.929; LFnu = 0.973; HFnu = 0.973; LF/HF = 0.942). The calculation of HRV values by means of temporal series obtained from the Polar S810i instrument appears to be as reliable as those obtained by processing the ECG signal captured with a signal conditioner.
引用
收藏
页码:854 / 859
页数:6
相关论文
共 50 条
  • [31] Evaluation of frequency and time-frequency spectral analysis of heart rate variability as a diagnostic marker of the sleep apnoea syndrome
    M. F. Hilton
    R. A. Bates
    K. R. Godfrey
    M. J. Chappell
    R. M. Cayton
    Medical & Biological Engineering & Computing, 1999, 37 : 760 - 769
  • [32] A new approach for time-frequency analysis of heart rate variability and assessment of time-frequency representations
    Chan, HL
    Huang, HH
    Wu, CP
    Lin, JL
    JOURNAL OF THE CHINESE INSTITUTE OF ENGINEERS, 1997, 20 (03) : 343 - 353
  • [33] Heart rate variability analysis based on time-frequency representation and entropies in hypertrophic cardiomyopathy patients
    Claria, F.
    Vallverdu, M.
    Baranowski, R.
    Chojnowska, L.
    Caminal, P.
    PHYSIOLOGICAL MEASUREMENT, 2008, 29 (03) : 401 - 416
  • [34] Automatic arrhythmia detection based on time and time-frequency analysis of heart rate variability
    Tsipouras, MG
    Fotiadis, DI
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2004, 74 (02) : 95 - 108
  • [35] Comparison of nonparametric and parametric methods for time-frequency heart rate variability analysis in a rodent model of cardiovascular disease
    Wong, Emily M.
    Tablin, Fern
    Schelegle, Edward S.
    PLOS ONE, 2020, 15 (11):
  • [36] Online Algorithm for Deriving Heart Rate Variability Components and Their Time-Frequency Analysis
    Adamczyk, Krzysztof
    Polak, Adam G.
    APPLIED SCIENCES-BASEL, 2025, 15 (03):
  • [37] Time-Frequency Analysis of Heart Rate Variability in Neonatal Piglets Exposed to Hypoxia
    Dong, Shiying
    Mesbah, Mostefa
    Lingwood, Barbara E.
    Toole, John M. O'
    Boashash, Boualem
    2011 COMPUTING IN CARDIOLOGY, 2011, 38 : 701 - 704
  • [38] Time–Frequency Analysis of Variability in External Respiration and Heart Rate in Humans during Exercise
    Grishin V.G.
    Grishin O.V.
    Nikultsev V.S.
    Gultyaeva V.V.
    Zinchenko M.I.
    Uryumtsev D.Y.
    Biophysics, 2022, 67 (4) : 605 - 611
  • [39] Comparison of heart rate variability analysis methods in patients with Parkinson's disease
    Kallio, M
    Suominen, K
    Bianchi, AM
    Mäkikallio, T
    Haapaniemi, T
    Astafiev, S
    Sotaniemi, KA
    Myllylä, VV
    Tolonen, U
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2002, 40 (04) : 408 - 414
  • [40] Time- and frequency-domain parameters of heart rate variability and sympathetic skin response in Parkinson's disease
    Maetzler, Walter
    Karam, Marie
    Berger, Monika Fruhmann
    Heger, Tanja
    Maetzler, Corina
    Ruediger, Heinz
    Bronzova, Juliana
    Lobo, Patricia Pita
    Ferreira, Joaquim J.
    Ziemssen, Tjalf
    Berg, Daniela
    JOURNAL OF NEURAL TRANSMISSION, 2015, 122 (03) : 419 - 425