Glucose monitoring by reverse iontophoresis

被引:143
作者
Potts, RO [1 ]
Tamada, JA [1 ]
Tierney, MJ [1 ]
机构
[1] Cygnus Inc, Redwood City, CA 94063 USA
关键词
glucose; non-invasive monitoring; iontophoresis;
D O I
10.1002/dmrr.210
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Glucose can be extracted through intact skin by electro-osmotic flow (a process called 'reverse iontophoresis') upon the application of a low-level electrical current. Recently we have combined iontophoretic extraction with an in situ glucose sensor in a device called the GlucoWatch(R) biographer. Clinical results with this device show close tracking of blood glucose over a range of 2.2 to 22.2 mmol/l for up to 12 h using a single blood glucose value as calibration. The biographer readings lag behind blood glucose values by an average of 18 min. An analysis of data from 92 diabetic subjects in a controlled clinical setting shows a linear relationship (r=0.88) between GlucoWatch biographer readings and blood glucose. The mean absolute relative difference between the two measurements was 15.6% and more than 96% of the data fell in the (A+B) regions of the Clarke error grid. Similar results have been obtained from subjects using the GlucoWatch biographer in an uncontrolled home environment. The automatic, frequent, and non-invasive measurements obtained with the GlucoWatch biographer provide substantially more information about glucose levels than do the current fingerstick methods. This information can be used for improved decisions about all aspects of diabetes management. Copyright (C) 2002 John Wiley Sons, Ltd.
引用
收藏
页码:S49 / S53
页数:5
相关论文
共 11 条
  • [1] EVALUATING CLINICAL ACCURACY OF SYSTEMS FOR SELF-MONITORING OF BLOOD-GLUCOSE
    CLARKE, WL
    COX, D
    GONDERFREDERICK, LA
    CARTER, W
    POHL, SL
    [J]. DIABETES CARE, 1987, 10 (05) : 622 - 628
  • [2] Diabetes Control and Complications Trial Research Group, 1993, NEW ENGL J MED, V329, P997
  • [3] Correlation at fingerstick blood glucose measurements with GlucoWatch biographer glucose results in young subjects with type 1 diabetes
    Garg, SK
    Potts, RO
    Ackerman, NR
    Fermi, SJ
    Tamada, JA
    Chase, HP
    [J]. DIABETES CARE, 1999, 22 (10) : 1708 - 1714
  • [4] A WARD COMPARISON BETWEEN THE ONE TOUCH-II AND GLUCOMETER-II BLOOD-GLUCOSE METERS
    KILPATRICK, ES
    MCLEOD, MJ
    RUMLEY, AG
    SMALL, M
    [J]. DIABETIC MEDICINE, 1994, 11 (02) : 214 - 217
  • [5] Application of the Mixtures of Experts algorithm for signal processing in a noninvasive glucose monitoring system
    Kurnik, RT
    Oliver, JJ
    Waterhouse, SR
    Dunn, T
    Jayalakshmi, Y
    Lesho, M
    Lopatin, M
    Tamada, J
    Wei, C
    Potts, RO
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 1999, 60 (01) : 19 - 26
  • [6] ON LINE CONTINUOUS MONITORING OF SUBCUTANEOUS TISSUE GLUCOSE IN MEN BY COMBINING PORTABLE GLUCOSENSOR WITH MICRODIALYSIS
    MEYERHOFF, C
    BISCHOF, F
    STERNBERG, F
    ZIER, H
    PFEIFFER, EF
    [J]. DIABETOLOGIA, 1992, 35 (11) : 1087 - 1092
  • [7] POITOUT V, 1991, T AM SOC ART INT ORG, V37, pM298
  • [8] Noninvasive glucose monitoring - Comprehensive clinical results
    Tamada, JA
    Garg, S
    Jovanovic, L
    Pitzer, KR
    Fermi, S
    Potts, RO
    [J]. JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1999, 282 (19): : 1839 - 1844
  • [9] MEASUREMENT OF GLUCOSE IN DIABETIC SUBJECTS USING NONINVASIVE TRANSDERMAL EXTRACTION
    TAMADA, JA
    BOHANNON, NJV
    POTTS, RO
    [J]. NATURE MEDICINE, 1995, 1 (11) : 1198 - 1201
  • [10] Tierney MJ, 1999, CLIN CHEM, V45, P1681