Hollow-fiber liquid-phase microextraction and gas chromatography-mass spectrometry of barbiturates in whole blood samples

被引:21
作者
de Almeida, Rafael Menck [1 ]
de Lima, Diogenes Saulo [1 ]
Seulin, Saskia Carolina [2 ]
Leyton, Vilma [2 ]
Pasqualucci, Carlos Augusto [2 ,3 ]
Munoz, Daniel Romero [2 ]
Osselton, Michael David [4 ]
Yonamine, Mauricio [1 ]
机构
[1] Univ Sao Paulo, Fac Pharmaceut Sci, BR-05508 Sao Paulo, Brazil
[2] Univ Sao Paulo, Fac Med, BR-05508 Sao Paulo, Brazil
[3] Univ Sao Paulo, Death Verificat Serv, BR-05508 Sao Paulo, Brazil
[4] Bournemouth Univ, Dept Forens & Biol Sci, Poole BH12 5BB, Dorset, England
基金
巴西圣保罗研究基金会;
关键词
Barbiturates; GC-MS; Liquid-phase microextraction; Whole blood; SERUM; CONFIRMATION;
D O I
10.1002/jssc.201200444
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Here, we present a method for measuring barbiturates (butalbital, secobarbital, pentobarbital, and phenobarbital) in whole blood samples. To accomplish these measurements, analytes were extracted by means of hollow-fiber liquid-phase microextraction in the three-phase mode. Hollow-fiber pores were filled with decanol, and a solution of sodium hydroxide (pH 13) was introduced into the lumen of the fiber (acceptor phase). The fiber was submersed in the acidified blood sample, and the system was subjected to an ultrasonic bath. After a 5 min extraction, the acceptor phase was withdrawn from the fiber and dried under a nitrogen stream. The residue was reconstituted with ethyl acetate and trimethylanilinium hydroxide. An aliquot of 1.0 mu L of this solution was injected into the gas chromatograph/mass spectrometer, with the derivatization reaction occurring in the hot injector port (flash methylation). The method proved to be simple and rapid, and only a small amount of organic solvent (decanol) was needed for extraction. The detection limit was 0.5 mu g/mL for all the analyzed barbiturates. The calibration curves were linear over the specified range (1.0 to 10.0 mu g/mL). This method was successfully applied to postmortem samples (heart blood and femoral blood) collected from three deceased persons previously exposed to barbiturates.
引用
收藏
页码:3361 / 3368
页数:8
相关论文
共 22 条
  • [1] Albertson T. E., 2004, POISON DRUG OVERDOSE
  • [2] Profile of suicide attempts using intentional overdose with medicines, treated by a poison control center in Parana State, Brazil
    Bernardes, Sara Santos
    Turini, Conceicao Aparecida
    Matsuo, Tiemi
    [J]. CADERNOS DE SAUDE PUBLICA, 2010, 26 (07): : 1366 - 1372
  • [3] Antiepileptic drugs: a study of 1028 cases registered by the Sao Paulo intoxication Control Center
    Bonilha, L
    Collares, CF
    do Amaral, DA
    Barcia, SD
    Oliveira, AMAD
    Li, LM
    [J]. SEIZURE-EUROPEAN JOURNAL OF EPILEPSY, 2005, 14 (03): : 170 - 174
  • [4] Determination in serum of some barbiturates using micellar liquid chromatography with direct injection
    Capella-Peiró, ME
    Gil-Agustí, M
    Martinavarro-Domínguez, A
    Esteve-Romero, J
    [J]. ANALYTICAL BIOCHEMISTRY, 2002, 309 (02) : 261 - 268
  • [5] Postmortem drug analysis: Analytical and toxicological aspects
    Drummer, OH
    Gerostamoulos, J
    [J]. THERAPEUTIC DRUG MONITORING, 2002, 24 (02) : 199 - 209
  • [6] Barbiturate Detection in Oral Fluid, Plasma, and Urine
    Fritch, Dean
    Blum, Kristen
    Nonnemacher, Sheena
    Kardos, Keith
    Buchhalter, August R.
    Cone, Edward J.
    [J]. THERAPEUTIC DRUG MONITORING, 2011, 33 (01) : 72 - 79
  • [7] Determination of barbiturates by solid-phase microextraction (SPME) and ion trap gas chromatography mass spectrometry
    Hall, BJ
    Brodbelt, JS
    [J]. JOURNAL OF CHROMATOGRAPHY A, 1997, 777 (02) : 275 - 282
  • [8] Recovery, enrichment and selectivity in liquid-phase microextraction - Comparison with conventional liquid-liquid extraction
    Ho, TS
    Pedersen-Bjergaard, S
    Rasmussen, KE
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2002, 963 (1-2) : 3 - 17
  • [9] Simultaneous determination of barbiturates in human biological fluids by direct immersion solid-phase microextraction and gas chromatography-mass spectrometry
    Iwai, M
    Hattori, H
    Arinobu, T
    Ishii, A
    Kumazawa, T
    Noguchi, H
    Noguchi, H
    Suzuki, O
    Seno, H
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2004, 806 (01): : 65 - 73
  • [10] Johnson LL, 2010, METHODS MOL BIOL, V603, P65, DOI 10.1007/978-1-60761-459-3_7