An integrated microfluidic cell culture system for high-throughput perfusion three-dimensional cell culture-based assays: effect of cell culture model on the results of chemosensitivity assays

被引:56
作者
Huang, Song-Bin [1 ]
Wang, Shih-Siou [1 ]
Hsieh, Chia-Hsun [2 ,3 ]
Lin, Yung Chang [3 ]
Lai, Chao-Sung [4 ]
Wu, Min-Hsien [1 ]
机构
[1] Chang Gung Univ, Grad Inst Biochem & Biomed Engn, Tao Yuan 333, Taiwan
[2] Chang Gung Univ, Dept Chem & Mat Engn, Tao Yuan 333, Taiwan
[3] Chang Gung Mem Hosp, Dept Haematol & Oncol, Div Med Oncol, Tao Yuan 333, Taiwan
[4] Chang Gung Univ, Dept Elect Engn, Tao Yuan 333, Taiwan
关键词
TISSUE-CULTURE; MICROBIOREACTOR; CHONDROCYTES; CISPLATIN; COLLAGEN; ARRAY;
D O I
10.1039/c2lc41264k
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Although microfluidic cell culture systems are versatile tools for cellular assays, their use has yet to set in motion an evolutionary shift away from conventional cell culture methods. This situation is mainly due to technical hurdles: the operational barriers to the end-users, the lack of compatible detection schemes capable of reading out the results of a microfluidic-based cellular assay, and the lack of fundamental data to bridge the gap between microfluidic and conventional cell culture models. To address these issues, we propose a high-throughput, perfusion, three-dimensional (3-D) microfluidic cell culture system encompassing 30 microbioreactors. This integrated system not only aims to provide a user-friendly cell culture tool for biologists to perform assays but also to enable them to obtain precise data. Its technical features include (i) integration of a heater chip based on transparent indium tin oxide glass, providing stable thermal conditions for cell culturing; (ii) a microscale 3-D culture sample loading scheme that is both efficient and precise; (iii) a non-mechanical pneumatically driven multiplex medium perfusion mechanism; and (iv) a microplate reader-compatible waste medium collector array for the subsequent high throughput bioassays. In this study, we found that the 3-D culture sample loading method provided uniform sample loading [coefficient of variation (CV): 3.2%]. In addition, the multiplex medium perfusion mechanism led to reasonably uniform (CV: 3.6-6.9%) medium pumping rates in the 30 microchannels. Moreover, we used the proposed system to perform a successful cell culture-based chemosensitivity assay. To determine the effects of cell culture models on the cellular proliferation, and the results of chemosensitivity assays, we compared our data with that obtained using three conventional cell culture models. We found that the nature of the cell culture format could lead to different evaluation outcomes. Consequently, when establishing a cell culture model for in vitro cell-based assays, it might be necessary to investigate the fundamental physiological variations of the cultured cells in different culture systems to avoid any misinterpretation of data. As a whole, we have developed an integrated microfluidic cell culture system that overcomes several technical hurdles commonly encountered in the practical application of microfluidic cell culture systems, and we have obtained fundamental information to reconcile differences found with data acquired using conventional methods.
引用
收藏
页码:1133 / 1143
页数:11
相关论文
共 37 条
[21]   A coupled field study on the non-linear dynamic characteristics of an electrostatic micropump [J].
Ng, TY ;
Jiang, TY ;
Li, H ;
Lam, KY ;
Reddy, JN .
JOURNAL OF SOUND AND VIBRATION, 2004, 273 (4-5) :989-1006
[22]   Self assembly of amphiphilic C60 fullerene derivatives into nanoscale supramolecular structures [J].
Partha R. ;
Lackey M. ;
Hirsch A. ;
Casscells S.W. ;
Conyers J.L. .
Journal of Nanobiotechnology, 5 (1)
[23]   Comparison of 3D and 2D tumor models reveals enhanced HER2 activation in 3D associated with an increased response to trastuzumab [J].
Pickl, M. ;
Ries, C. H. .
ONCOGENE, 2009, 28 (03) :461-468
[24]   Culture of skin cells in 3D rather than 2D improves their ability to survive exposure to cytotoxic agents [J].
Sun, T ;
Jackson, S ;
Haycock, JW ;
MacNeil, S .
JOURNAL OF BIOTECHNOLOGY, 2006, 122 (03) :372-381
[25]   Cells lying on a bed of microneedles: An approach to isolate mechanical force [J].
Tan, JL ;
Tien, J ;
Pirone, DM ;
Gray, DS ;
Bhadriraju, K ;
Chen, CS .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2003, 100 (04) :1484-1489
[26]   A microfluidic 3D hepatocyte chip for drug toxicity testing [J].
Toh, Yi-Chin ;
Lim, Teck Chuan ;
Tai, Dean ;
Xiao, Guangfa ;
van Noort, Danny ;
Yu, Hanry .
LAB ON A CHIP, 2009, 9 (14) :2026-2035
[27]   Multi-channel 3-D cell culture device integrated on a silicon chip for anticancer drug sensitivity test [J].
Torisawa, Y ;
Shiku, H ;
Yasukawa, T ;
Nishizawa, M ;
Matsue, T .
BIOMATERIALS, 2005, 26 (14) :2165-2172
[28]   Monolithic microfabricated valves and pumps by multilayer soft lithography [J].
Unger, MA ;
Chou, HP ;
Thorsen, T ;
Scherer, A ;
Quake, SR .
SCIENCE, 2000, 288 (5463) :113-116
[29]   Microenvironment design considerations for cellular scale studies [J].
Walker, GM ;
Zeringue, HC ;
Beebe, DJ .
LAB ON A CHIP, 2004, 4 (02) :91-97
[30]   Microplate-Reader Compatible Perfusion Microbioreactor Array for Modular Tissue Culture and Cytotoxicity Assays [J].
Wen, Yuan ;
Zhang, Xudong ;
Yang, Shang-Tian .