Changes in the Fractal Dimension, Feret Diameter, and Lacunarity of Mandibular Alveolar Bone During Initial Healing of Dental Implants

被引:0
作者
Onem, Erinc [1 ]
Baksi, B. Guniz [1 ]
Sogur, Elif [1 ]
机构
[1] Ege Univ, Dept Oral Diag & Radiol, Sch Dent, TR-35100 Izmir, Turkey
关键词
dental implants; Feret diameter; fractal dimension; lacunarity; panoramic radiography; VERTEBRAL TRABECULAR BONE; TEXTURE ANALYSIS; CT IMAGES; OSTEOPOROSIS; RADIOGRAPHS; PATTERN; JAWS;
D O I
暂无
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: To evaluate the combination of fractal dimension (FD), lacunarity, and Feret diameter (FeD) to quantitatively characterize structural changes of mandibular alveolar bone around dental implants during initial healing. Materials and Methods: Three standard-sized regions of interest (ROIs) (mesial and distal crest and apical area) around implants and three ROIs of the same size in the alveolar bone on the contralateral side were analyzed on digital panoramic images. FD was calculated using the box-counting method, and lacunarity was calculated using the FracLac plugin of Image J software. FeD was measured in the same ROIs. Comparisons of the groups were done with the Dunnett test. Results: Forty-two implants in the posterior mandibles of 21 patients were used for FD measurements. A total of 189 ROIs was segmented into binary images. Mean FD values for mesial, distal, and apical ROIs around implants were 1.26, 1.36, and 1.4, respectively. The mean FD of alveolar bone around premolars/molars was 1.39 for all ROIs. The mean FeD for mesial, distal, and apical ROIs around implants was 7.63, 7.86, and 8.02, respectively, whereas it ranged between 7.88 and 8.13 for premolar teeth. Mean lacunarity values for mesial, distal, and apical ROIs around implants were 0.53, 0.51, and 0.48, respectively. Lacunarity values for ROIs around premolars ranged between 0.45 and 0.50. No significant differences were observed in FD, FeD, or lacunarity measurements between ROIs around implants and around teeth. Conclusions: The satisfactory healing of bone following implant placement may be monitored by calculating FD, lacunarity, and FeD using digital panoramic images. Although preliminary, these values may alert the practitioner to any implants with loss of stability. INT J ORAL MAXILLOFAC IMPLANTS 2012;27:1009-1013
引用
收藏
页码:1009 / 1013
页数:5
相关论文
共 34 条
  • [1] Texture analysis of aggressive and nonaggressive lung tumor CE CT images
    Al-Kadi, Omar S.
    Watson, D.
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2008, 55 (07) : 1822 - 1830
  • [2] Digital imaging analysis with mathematical morphology and fractal dimension for evaluation of periapical lesions following endodontic treatment
    Chen, SK
    Oviir, T
    Lin, CH
    Len, LJ
    Cho, BH
    Hollender, L
    [J]. ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 2005, 100 (04): : 467 - 472
  • [3] A comparison of the texture of computed tomography and projection radiography images of vertebral trabecular bone using fractal signature and lacunarity
    Dougherty, G
    [J]. MEDICAL ENGINEERING & PHYSICS, 2001, 23 (05) : 313 - 321
  • [4] Lacunarity analysis of spatial pattern in CT images of vertebral trabecular bone for assessing osteoporosis
    Dougherty, G
    Henebry, GM
    [J]. MEDICAL ENGINEERING & PHYSICS, 2002, 24 (02) : 129 - 138
  • [5] VASCULAR FRACTAL DIMENSION AND TOTAL VASCULAR AREA IN THE STUDY OF ORAL CANCER
    Goutzanis, Lampros P.
    Papadogeorgakis, Nikolaos
    Pavlopoulos, Petros M.
    Petsinis, Vasilis
    Plochoras, Ioannis
    Eleftheriadis, Efstathios
    Pantelidaki, Aikaterini
    Patsouris, Efstratios
    Alexandridis, Constantinos
    [J]. HEAD AND NECK-JOURNAL FOR THE SCIENCES AND SPECIALTIES OF THE HEAD AND NECK, 2009, 31 (03): : 298 - 307
  • [6] Fractal analysis of mandibular bony healing after orthognathic surgery
    Heo, MS
    Park, KS
    Lee, SS
    Choi, SC
    Koak, JY
    Heo, SJ
    Han, CH
    Kim, JD
    [J]. ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2002, 94 (06): : 763 - 767
  • [7] Image J, IMAGE J VERSION 1 34
  • [8] An evaluation of the origin of trabecular bone patterns using visual and digital image analysis
    Jett, S
    Shrout, MK
    Mailhot, JM
    Potter, BJ
    Borke, JL
    [J]. ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2004, 98 (05): : 598 - 604
  • [9] Lee Dae-Hyun, 2010, J Periodontal Implant Sci, V40, P19, DOI 10.5051/jpis.2010.40.1.19
  • [10] APPLICATION OF FRACTAL GEOMETRY TECHNIQUES TO THE STUDY OF TRABECULAR BONE
    MAJUMDAR, S
    WEINSTEIN, RS
    PRASAD, RR
    [J]. MEDICAL PHYSICS, 1993, 20 (06) : 1611 - 1619