A-Priori Calibration of a Structured Light Underwater 3D Sensor

被引:7
作者
Braeuer-Burchardt, Christian [1 ]
Munkelt, Christoph [1 ]
Gebhart, Ingo [1 ]
Heinze, Matthias [1 ]
Heist, Stefan [1 ]
Kuehmstedt, Peter [1 ]
Notni, Gunther [1 ,2 ]
机构
[1] Fraunhofer Inst Appl Opt & Precis Engn IOF, Albert Einstein Str 7, D-07745 Jena, Germany
[2] Ilmenau Univ Technol, Dept Mech Engn, Gustav Kirchhoff Pl 2, D-98693 Ilmenau, Germany
关键词
underwater 3D scanning; structured light projection; calibration; measurement accuracy; LENGTH;
D O I
10.3390/jmse8090635
中图分类号
U6 [水路运输]; P75 [海洋工程];
学科分类号
0814 ; 081505 ; 0824 ; 082401 ;
摘要
In this study, we introduce a new calibration method for underwater optical stereo scanners. It uses air calibration, additional underwater parameters, and extended camera modeling. The new methodology can be applied to both passive photogrammetric and structured light three-dimensional (3D) scanning systems. The novel camera model uses a variable principal distance depending on the radial distance to the principal point instead of two-dimensional distortion functions. This allows for an initial improvement of 3D reconstruction quality. In a second step, certain underwater-specific parameters-such as refraction indices, glass thickness, and view-port distances-are determined. Finally, a correction function for the entire measurement volume can be obtained from a few underwater measurements. Its application further improves the measurement accuracy. Measurement examples show the performance of the new calibration method in comparison to current underwater calibration strategies. A discussion of the possibilities and limits of the new calibration method and an outlook for future work complete this work.
引用
收藏
页数:13
相关论文
共 34 条
[1]  
[Anonymous], 2011, SPRINGER LNCS
[2]  
[Anonymous], 2013, IEEE
[3]  
[Anonymous], 1996, Mar. Geod, DOI DOI 10.1080/01490419709388103
[4]  
[Anonymous], 2014, P 5 MART INT WORKSH
[5]  
[Anonymous], 2010, OCEANS 2010 IEEE-Sydney, DOI [10.1109/OCEANSSYD.2010.5603672, DOI 10.1109/OCEANSSYD.2010.5603672]
[6]  
[Anonymous], 2003, INT ARCH PHOTOGRAMME
[7]   A Comparative Analysis between Active and Passive Techniques for Underwater 3D Reconstruction of Close-Range Objects [J].
Bianco, Gianfranco ;
Gallo, Alessandro ;
Bruno, Fabio ;
Muzzupappa, Maurizio .
SENSORS, 2013, 13 (08) :11007-11031
[8]   Underwater 3D Surface Measurement Using Fringe Projection Based Scanning Devices [J].
Braeuer-Burchardt, Christian ;
Heinze, Matthias ;
Schmidt, Ingo ;
Kuehmstedt, Peter ;
Notni, Gunther .
SENSORS, 2016, 16 (01)
[9]   Combination of Air- and Water-Calibration for a Fringe Projection Based Underwater 3D-Scanner [J].
Braeuer-Burchardt, Christian ;
Kuehmstedt, Peter ;
Notni, Gunther .
COMPUTER ANALYSIS OF IMAGES AND PATTERNS, CAIP 2015, PT II, 2015, 9257 :49-60
[10]  
Brauer-Burchardt C., 2018, P IWCIA 2018 PORT PO, V11255, P202