PexLoc-Parallel Excitation Using Local Encoding Magnetic Fields with Nonlinear and Nonbijective Spatial Profiles

被引:11
作者
Haas, M. [1 ]
Ullmann, P. [2 ]
Schneider, J. T. [1 ,2 ]
Post, H. [2 ]
Ruhm, W. [2 ]
Hennig, J. [1 ]
Zaitsev, M. [1 ]
机构
[1] Univ Med Ctr Freiburg, Dept Radiol, D-79106 Freiburg, Germany
[2] Bruker BioSpin MRI GmbH, Ettlingen, Germany
关键词
spatially selective excitation (SSE); parallel excitation (PEX); nonlinear encoding fields; PatLoc; SELECTIVE EXCITATION; RF PULSES; MR SPECTROSCOPY; DESIGN; LOCALIZATION; TRANSMISSION; CHANNELS; VOXELS; SENSE;
D O I
10.1002/mrm.24559
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
With the recent proposal of using magnetic fields that are nonlinear by design for spatial encoding, new flexibility has been introduced to MR imaging. The new degrees of freedom in shaping the spatially encoding magnetic fields (SEMs) can be used to locally adapt the imaging resolution to features of the imaged object, e.g., anatomical structures, to reduce peripheral nerve stimulation during in vivo experiments or to increase the gradient switching speed by reducing the inductance of the coils producing the SEMs and thus accelerate the imaging process. In this work, the potential of nonlinear and nonbijective SEMs for spatial encoding during transmission in multidimensional spatially selective excitation is explored. Methods for multidimensional spatially selective excitation radiofrequency pulse design based on nonlinear encoding fields are introduced, and it is shown how encoding ambiguities can be resolved using parallel transmission. In simulations and phantom experiments, the feasibility of selective excitation using nonlinear, nonbijective SEMs is demonstrated, and it is shown that the spatial resolution with which the target distribution of the transverse magnetization can be realized varies locally. Thus, the resolution of the target pattern can be increased in some regions compared with conventional linear encoding. Furthermore, experimental proof of principle of accelerated two-dimensional spatially selective excitation using nonlinear SEMs is provided in this study. Magn Reson Med 70:1220-1228, 2013. (c) 2012 Wiley Periodicals, Inc.
引用
收藏
页码:1220 / 1228
页数:9
相关论文
共 41 条
[1]   Angiographic imaging with 2D RF pulses [J].
Alley, MT ;
Pauly, JM ;
Sommer, FG ;
Pelc, NJ .
MAGNETIC RESONANCE IN MEDICINE, 1997, 37 (02) :260-267
[2]   A Transmit/Receive System for Magnetic Field Monitoring of In Vivo MRI [J].
Barmet, Christoph ;
De Zanche, Nicola ;
Wilm, Bertram J. ;
Pruessmann, Klaas P. .
MAGNETIC RESONANCE IN MEDICINE, 2009, 62 (01) :269-276
[3]  
Börnert P, 1998, MAGN RESON MATER PHY, V7, P166
[4]   Curved slice imaging [J].
Bornert, P ;
Schaffter, T .
MAGNETIC RESONANCE IN MEDICINE, 1996, 36 (06) :932-939
[5]   Hadamard-encoding combined with two-dimensional-selective radiofrequency excitations for flexible and efficient acquisitions of multiple voxels in MR spectroscopy [J].
Busch, Martin G. ;
Finsterbusch, Juergen .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2012, 35 (04) :976-983
[6]   Spatially 2D-Selective RF Excitations Using the PROPELLER Trajectory: Basic Principles and Application to MR Spectroscopy of Irregularly Shaped Single Voxel [J].
Busch, Martin G. ;
Finsterbusch, Juergen .
MAGNETIC RESONANCE IN MEDICINE, 2011, 66 (05) :1218-1225
[7]  
Cocosco CA, 2011, P 19 ANN M ISMRM MON, P714
[8]   2-DIMENSIONAL SELECTIVE ADIABATIC PULSES [J].
CONOLLY, S ;
PAULY, J ;
NISHIMURA, D ;
MACOVSKI, A .
MAGNETIC RESONANCE IN MEDICINE, 1992, 24 (02) :302-313
[9]   Simultaneously Driven Linear and Nonlinear Spatial Encoding Fields in MRI [J].
Gallichan, Daniel ;
Cocosco, Chris. A. ;
Dewdney, Andrew ;
Schultz, Gerrit ;
Welz, Anna ;
Hennig, Juergen ;
Zaitsev, Maxim .
MAGNETIC RESONANCE IN MEDICINE, 2011, 65 (03) :702-714
[10]  
Grissom W.A., 2011, Proc. 19th Ann. Meet. Soc. Mag. Reson. Med, P2898