Effective compliance during the first 3 months of continuous positive airway pressure -: A European prospective study of 121 patients

被引:186
|
作者
Pépin, JL
Krieger, J
Rodenstein, D
Cornette, A
Sforza, E
Delguste, P
Deschaux, C
Grillier, V
Lévy, P
机构
[1] Univ Hosp, Dept Resp Med & Sleep Lab, Grenoble, France
[2] Univ Hosp, Sleep Disorders Unit, Strasbourg, France
[3] Univ Hosp Nancy, Resp Dept, Vandoeuvre Nancy, France
[4] Univ Catholique Louvain, Clin Univ St Luc, Resp Dept, B-1200 Brussels, Belgium
[5] Nellcor Puritan Bennett FD, Nancy Les Villers, France
[6] Univ Grenoble 1, PRETA Lab, UMR CNRS 5525, Dept Physiol,Fac Med, Grenoble, France
关键词
D O I
10.1164/ajrccm.160.4.9802027
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Effective compliance (time spent at the effective pressure) with nasal CPAP in obstructive sleep apnea has been reported to be poor. The aim of our study was to evaluate effective compliance in a large European multicenter study. One hundred twenty-one consecutive newly treated patients (initial apnea-hypopnea index [AHI] = 62.0 +/- 29.5/h, AHI under CPAP = 6.4 +/- 8.1/h, CPAP pressure = 8.7 +/- 2.6 cm H2O, BMI = 33.1 +/- 6.8 kg/m(2)) were randomly allocated to a group with (MC+) (n = 58) or without (MC-) (n = 63) a control unit measuring effective compliance at 1, 2 and 3 mo, which was compared with the built-in time counter data. MC+ data were 94 +/- 10, 98 +/- 5, and 96 +/- 9% of counter data at 1, 2, and 3 mo, respectively. Using criteria of regular use already reported in the literature (at least 4 h of nCPAP per day of use and nCPAP administered more than 70% of the days) we found 77, 82, and 79% compliant patients at 1, 2, and 3 mo, respectively, 79% of the patients meeting these criteria each month. Although there were no pulmonary functions or polysomnographic differences between the two subgroups, the compliant patients did report a greater improvement in minor symptoms. We found a close correlation between effective use of CPAP and the machine run time. The main result of our study was a higher effective compliance than previously reported, approximately 80% of the patients being regular users versus 46% in a previously published study. This may result from different technical and medical follow-up.
引用
收藏
页码:1124 / 1129
页数:6
相关论文
共 50 条
  • [41] Effects of intranasal steroids on continuous positive airway pressure compliance among patients with obstructive sleep apnea
    Charnsiri Segsarnviriya
    Rutti Chumthong
    Prasit Mahakit
    Sleep and Breathing, 2021, 25 : 1293 - 1299
  • [42] Evidence of interrelated side effects with reduced compliance in patients treated with nasal continuous positive airway pressure
    Baltzan, Marcel A.
    Elkholi, Osama
    Wolkove, Norman
    SLEEP MEDICINE, 2009, 10 (02) : 198 - 205
  • [43] Predictors of continuous positive airway pressure compliance in patients with obstructive sleep apnea and paroxysmal atrial fibrillation
    Vik-Strandli, M.
    Traaen, G. M.
    Oeverland, B.
    Aakeroey, L.
    Hunt, T. E.
    Bendz, C.
    Bredesen, N.
    Sande, L.
    Aakhus, S.
    Steinshamn, S.
    Anfinsen, O. G.
    Loennechen, J. P.
    Akre, H.
    Gullestad, L.
    EUROPEAN JOURNAL OF HEART FAILURE, 2020, 22 : 169 - 169
  • [44] THE EFFECTS OF TOPICAL NASAL STEROIDS ON CONTINUOUS POSITIVE AIRWAY PRESSURE COMPLIANCE IN PATIENTS WITH OBSTRUCTIVE SLEEP APNEA
    Segsarnviriya, C.
    Mahakit, P.
    SLEEP, 2020, 43 : A239 - A239
  • [45] POOR COMPLIANCE OF CONTINUOUS POSITIVE AIRWAY PRESSURE THERAPY IN PATIENTS WITH MIXED-DOMINANT SLEEP APNEAS
    Koo, D.
    Hwang, K.
    Kim, S.
    Joo, E.
    Hong, S.
    SLEEP, 2012, 35 : A175 - A175
  • [46] Effects of humidification on nasal symptoms and compliance in sleep apnea patients using continuous positive airway pressure
    Massie, CA
    Hart, RW
    Peralez, K
    Richards, GN
    CHEST, 1999, 116 (02) : 403 - 408
  • [47] Long-term compliance with continuous positive airway pressure in patients with obstructive sleep apnea syndrome
    Wali, SO
    ANNALS OF SAUDI MEDICINE, 1997, 17 (06) : 616 - 618
  • [48] COMPLIANCE OF CONTINUOUS POSITIVE AIRWAY PRESSURE (CPAP) IN OBSTRUCTIVE SLEEP APNOEA AMONG HOSPITAL PUTRAJAYA PATIENTS
    Kugan, R.
    Syisy, A. J.
    Singh, M. Balwinder
    SLEEP MEDICINE, 2019, 64 : S204 - S205
  • [49] Compliance to continuous positive airway pressure therapy in a group of Portuguese patients with obstructive sleep apnea syndrome
    Alves, Claudia
    Pinto Chaves Caminha, Jose Manuel
    da Silva, Antonio Martins
    Mendonca, Denisa
    SLEEP AND BREATHING, 2012, 16 (02) : 555 - 562
  • [50] Effect of compliance to continuous positive airway pressure on exacerbations, pulmonary function and symptoms in patients with overlap syndrome
    Voulgaris, A.
    Archontogeorgis, K.
    Nena, E.
    Paxinou, N.
    Fanaridis, M.
    Schiza, S.
    Steiropoulos, P.
    JOURNAL OF SLEEP RESEARCH, 2022, 31