Quality Assurance of a Two-Dimensional CCD Detector System Applied in Dosimetry

被引:8
|
作者
Sampaio, Francisco G. A. [1 ]
Del Lama, Lucas S. [1 ]
Sato, Rodrigo [2 ]
de Oliveira, David M. M. [1 ]
Czelusniak, Caroline [1 ]
de Oliveira, Lucas N. [3 ]
de Almeida, Adelaide [1 ]
机构
[1] Univ Sao Paulo, Dept Fis FFCLRP, BR-14015400 Ribeirao Preto, SP, Brazil
[2] Univ Tsukuba, Grad Sch Pure & Appl Sci, Tsukuba, Ibaraki 3058577, Japan
[3] Inst Fed Educ Ciencia & Tecnol Goias, BR-75400000 Inhumas, Go, Brazil
关键词
Charge-coupled device detector system; Fricke Xylenol Gel; modulation transfer function; radiotherapy dosimetry; FRICKE XYLENOL GEL; MODULATION TRANSFER-FUNCTION; CHARGE-COUPLED-DEVICES;
D O I
10.1109/TNS.2013.2240464
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Nowadays, charge-coupled devices (CCDs) are applied for many technological purposes, including areas as astronomy, medical diagnosis and the ones related to light detecting sensors. One of the main advantages of a digital detector is its ability to store and rapidly transfer information to digital equipments, where data can be computed (post-processing). In fact, this is a relevant feature for medical applications, specially for imaging fields, in which the radiation exposure time is highly controlled when different image quality adjustments are necessary. The main goal of this article is to demonstrate a CCD application for optical density-based dosimeters, where high accuracy and spatial resolution are required. An optical prototype was developed considering a visible light source and a CCD camera, allied with a computational processing routine. The system resolution was inferred through two different methodologies, which support a spatial resolution better than 0.5 mm: 1) a radiological test system (line pair gauge) and 2) the modulation transfer function (MTF). Results also indicate that, due to CCD suitable resolution, one and two dimension responses can be acquired. Considering the easiness and fastness of the process, the developed system exhibits potential applicability for radiotherapy dosimetry.
引用
收藏
页码:810 / 816
页数:7
相关论文
共 50 条
  • [31] Comparison of the Performance between Portal Dosimetry and a Commercial Two-dimensional Array System on Pretreatment Quality Assurance for Volumetric-modulated Arc and Intensity-modulated Radiation Therapy
    Kim, Yon-Lae
    Chung, Jin-Beom
    Kim, Jae-Sung
    Lee, Jeong-Woo
    Choi, Kyoung-Sik
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2014, 64 (08) : 1207 - 1212
  • [32] Two-Dimensional Burst Construction with QoS Assurance for OFDMA Mobile WiMAX System
    Alsahag, Ali Mohammed
    Ali, Borhanuddin M.
    Noordin, Nor Kamariah
    Mohamad, Hafizal
    Ramli, Nordin
    2014 IEEE 2ND INTERNATIONAL SYMPOSIUM ON TELECOMMUNICATION TECHNOLOGIES (ISTT), 2014, : 256 - 261
  • [33] Iterative learning control by two-dimensional system theory applied to a motion system
    Paszke, Wojciech
    Merry, Roel
    van de Molengraft, Rene
    2007 AMERICAN CONTROL CONFERENCE, VOLS 1-13, 2007, : 5484 - 5489
  • [34] Assessing the suitability of a two-dimensional array for routine quality assurance checks of flatness and symmetry
    Ibrahim, Salma
    Seshadri, Venkatakrishnan
    Charles, Paul
    PHYSICAL AND ENGINEERING SCIENCES IN MEDICINE, 2020, 43 (04) : 1451 - 1460
  • [35] Evaluation of a two-dimensional diode array for patient-specific quality assurance of HyperArc
    Popple, Richard A.
    Sullivan, Rodney J.
    Yuan, Yuan
    Wu, Xingen
    Covington, Elizabeth L.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2021, 22 (12): : 203 - 210
  • [36] Assessing the suitability of a two-dimensional array for routine quality assurance checks of flatness and symmetry
    Salma Ibrahim
    Venkatakrishnan Seshadri
    Paul Charles
    Physical and Engineering Sciences in Medicine, 2020, 43 : 1451 - 1460
  • [37] Use of a two-dimensional ionization chamber array for proton therapy quality assurance checks
    Arjomandy, B.
    Sahoo, N.
    Gillin, M.
    Zhu, X.
    MEDICAL PHYSICS, 2007, 34 (06) : 2502 - 2502
  • [38] Use of a two-dimensional ionization chamber array for proton therapy beam quality assurance
    Arjomandy, Bijan
    Sahoo, Narayan
    Ding, Xiaoning
    Gillin, Michael
    MEDICAL PHYSICS, 2008, 35 (09) : 3889 - 3894
  • [39] PATIENT DOSIMETRY QUALITY ASSURANCE PROGRAM WITH A COMMERCIAL DIODE SYSTEM
    LEE, PC
    SAWICKA, JM
    GLASGOW, GP
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1994, 29 (05): : 1175 - 1182
  • [40] DIFFRACTIVE TWO-DIMENSIONAL DIFFUSER FOR CCD COLOR CAMERA
    GALE, MT