Medical-grade footwear: the impact of fit and comfort

被引:28
作者
Hurst, Bessie [1 ]
Branthwaite, Helen [1 ]
Greenhalgh, Andrew [1 ]
Chockalingam, Nachiappan [1 ]
机构
[1] Staffordshire Univ, Fac Hlth Sci, Leek Rd, Stoke On Trent ST4 2DF, Staffs, England
关键词
Comfort; Footwear; Prescription footwear; Pressure measurement; Footwear fit; DIABETIC FOOT; PRESSURE; SHOES; RISK; PAIN;
D O I
10.1186/s13047-016-0184-z
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Pressure-related skin lesions on the digits are a significant cause of discomfort. Most foot pain related to ill-fitting shoes occurs in the forefoot and digital areas. Pain has been associated with poor shoe fit, reduced toe box volume, as well as contour and shape of the shoe Off-the-shelf medical-grade footwear is designed as an intervention for chronic lesions on the digits. These shoes are designed with a flexible neoprene fabric upper that is thought to reduce pressure on the forefoot and reduce discomfort associated with ill-fitting shoes. The aim of this study was to investigate the effect of an off-the-shelf, medical-grade shoe on dorsal digital pressure and perceived comfort when compared to participant's own preferred shoe. Methods: Thirty participants (18 females, 12 males) scored their perceived comfort whilst wearing each footwear style using a visual analog comfort scale. Dorsal digital and interdigital pressures were measured in using the WalkinSense (R) in-shoe pressure system. Sensors were placed on predetermined anatomical landmarks on the digits. Participants were randomly assigned the test shoe and their own shoe. Once wearing the shoe, the participants walked across a 6 m walkway and pressure data from each sensor was collected and processed to obtain peak pressure, time to peak pressure and contact time. Results: Participants scored the test shoe with higher comfort points than their own footwear. Overall peak pressure, pressure time integral and contact time decreased, whilst the time taken to reach peak pressure increased across all anatomical landmarks whilst wearing the test shoe. Statistically significant changes were observed for all of the measured variables relating to pressure on the medial border of the first metatarsophalangeal joint. Conclusion: The test shoe provided greater comfort and reduced the amount of pressure on the forefoot. The medical-grade footwear therefore, is a viable alternative to custom made prescription footwear and is more suitable than a regular everyday shoe when treating digital lesions associated with pressure.
引用
收藏
页数:7
相关论文
共 32 条
[1]  
APELQVIST J, 1990, Journal of Diabetic Complications, V4, P21, DOI 10.1016/0891-6632(90)90060-I
[2]   A qualitative study on the comfort and fit of ladies' dress shoes [J].
Au, Emily Yim Lee ;
Goonetilleke, Ravindra S. .
APPLIED ERGONOMICS, 2007, 38 (06) :687-696
[3]  
Bowker P, 1992, STUDY ORG ORTHOTIC S
[4]  
Branthwaite Helen, 2014, Foot (Edinb), V24, P116, DOI 10.1016/j.foot.2014.05.004
[5]   The effect of shoe toe box shape and volume on forefoot interdigital and plantar pressures in healthy females [J].
Branthwaite, Helen ;
Chockalingam, Nachiappan ;
Greenhalgh, Andrew .
JOURNAL OF FOOT AND ANKLE RESEARCH, 2013, 6
[6]  
Branthwaite HR, 2012, PROSTHET ORTHOT INT, V10, P1177
[8]   Assistive devices: usage in patients with rheumatoid arthritis [J].
de Boer, I. G. ;
Peeters, A. J. ;
Ronday, H. K. ;
Mertens, B. J. A. ;
Huizinga, T. W. J. ;
Vlieland, T. P. M. Vliet .
CLINICAL RHEUMATOLOGY, 2009, 28 (02) :119-128
[9]   The relationship between foot pain, anthropometric variables and footwear among older people [J].
de Castro, Alessandra Paiva ;
Rebelatto, Jose Rubens ;
Aurichio, Thais Rabiatti .
APPLIED ERGONOMICS, 2010, 41 (01) :93-97
[10]  
EDMONDS ME, 1986, Q J MED, V60, P763