Biodegradable Polymer Biolimus-Eluting Stent Versus Durable Polymer Everolimus-Eluting Stent A Randomized, Controlled, Noninferiority Trial

被引:176
作者
Natsuaki, Masahiro [1 ]
Kozuma, Ken [2 ]
Morimoto, Takeshi [3 ]
Kadota, Kazushige [4 ]
Muramatsu, Toshiya [5 ]
Nakagawa, Yoshihisa [6 ]
Akasaka, Takashi [7 ]
Igarashi, Keiichi [8 ]
Tanabe, Kengo [9 ]
Morino, Yoshihiro [10 ]
Ishikawa, Tetsuya [11 ]
Nishikawa, Hideo [12 ]
Awata, Masaki [13 ]
Abe, Mitsuru [14 ]
Okada, Hisayuki [15 ]
Takatsu, Yoshiki [16 ]
Ogata, Nobuhiko [17 ]
Kimura, Kazuo [18 ]
Urasawa, Kazushi [19 ]
Tarutani, Yasuhiro [20 ]
Shiode, Nobuo [21 ]
Kimura, Takeshi [1 ]
机构
[1] Kyoto Univ, Grad Sch Med, Dept Cardiovasc Med, Kyoto 6068507, Japan
[2] Teikyo Univ Hosp, Div Cardiol, Tokyo, Japan
[3] Kinki Univ, Sch Med, Ctr Gen Internal Med & Emergency Care, Osaka 589, Japan
[4] Kurashiki Cent Hosp, Dept Cardiol, Kurashiki, Okayama, Japan
[5] Saiseikai Yokohama City Eastern Hosp, Div Cardiol, Yokohama, Kanagawa, Japan
[6] Tenri Hosp, Div Cardiol, Tenri, Nara 632, Japan
[7] Wakayama Med Univ Hosp, Dept Cardiovasc Med, Wakayama, Japan
[8] Hokkaido Social Insurance Hosp, Div Cardiol, Sapporo, Hokkaido, Japan
[9] Mitsui Mem Hosp, Div Cardiol, Tokyo 101, Japan
[10] Iwate Med Univ Hosp, Div Cardiol, Morioka, Iwate, Japan
[11] Saitama Cardiovasc & Resp Ctr, Div Cardiol, Kumagaya, Saitama, Japan
[12] Mie Heart Ctr, Div Cardiol, Tsu, Mie, Japan
[13] Kansai Rosai Hosp, Div Cardiol, Amagasaki, Hyogo, Japan
[14] Natl Hosp Org, Kyoto Med Ctr, Div Cardiol, Kyoto, Japan
[15] Seirei Hamamatsu Gen Hosp, Div Cardiol, Hamamatsu, Shizuoka, Japan
[16] Hyogo Kenritsu Amagasaki Hosp, Div Cardiol, Amagasaki, Hyogo, Japan
[17] Tokai Univ Hosp, Div Cardiol, Isehara, Kanagawa, Japan
[18] Yokohama City Univ, Med Ctr, Div Cardiol, Yokohama, Kanagawa 232, Japan
[19] Caress Sapporo Tokeidai Mem Hosp, Div Cardiol, Sapporo, Hokkaido, Japan
[20] Okamura Mem Hosp, Div Cardiol, Shizuoka, Japan
[21] Tsuchiya Gen Hosp, Div Cardiol, Hiroshima, Japan
关键词
biolimus-eluting stent(s); everolimus-eluting stent(s); percutaneous coronary intervention; NON-INFERIORITY TRIAL; THROMBOSIS; DESIGN;
D O I
10.1016/j.jacc.2013.04.045
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives NEXT (NOBORI Biolimus-Eluting Versus XIENCE/PROMUS Everolimus-Eluting Stent Trial) was designed for evaluating the noninferiority of a biolimus-eluting stent (BES) relative to an everolimus-eluting stent (EES) in terms of target lesion revascularization (TLR) at 1 year. Background Efficacy and safety data comparing biodegradable polymer BES with durable polymer cobalt-chromium EES are currently limited. Methods The NEXT trial is a prospective, multicenter, randomized, open-label, noninferiority trial comparing BES with EES. Between May and October 2011, 3,235 patients were randomly assigned to receive either BES (n = 1,617) or EES (n = 1,618). Results At 1 year, the primary efficacy endpoint of TLR occurred in 67 patients (4.2%) in the BES group, and in 66 patients (4.2%) in the EES group, demonstrating noninferiority of BES relative to EES (p for noninferiority <0.0001, and p for superiority = 0.93). Cumulative incidence of definite stent thrombosis was low and similar between the 2 groups (0.25% vs. 0.06%, p = 0.18). An angiographic substudy enrolling 528 patients (BES: n = 263, and EES: n = 265) demonstrated noninferiority of BES relative to EES regarding the primary angiographic endpoint of in-segment late loss (0.03 +/- 0.39 mm vs. 0.06 +/- 0.45 mm, p for noninferiority <0.0001, and p for superiority = 0.52) at 266 +/- 43 days after stent implantation. Conclusions One-year clinical and angiographic outcome after BES implantation was noninferior to and not different from that after EES implantation in a mostly stable coronary artery disease population. One-year clinical outcome after both BES and EES use was excellent, with a low rate of TLR and extremely low rate of stent thrombosis. (c) 2013 by the American College of Cardiology Foundation
引用
收藏
页码:181 / 190
页数:10
相关论文
共 8 条
[1]   Biolimus-eluting biodegradable polymer-coated stent versus durable polymer-coated sirolimus-eluting stent in unselected patients receiving percutaneous coronary intervention (SORT OUT V): a randomised non-inferiority trial [J].
Christiansen, Evald Hoj ;
Jensen, Lisette Okkels ;
Thayssen, Per ;
Tilsted, Hans-Henrik ;
Krusell, Lars Romer ;
Hansen, Knud Norregaard ;
Kaltoft, Anne ;
Maeng, Michael ;
Kristensen, Steen Dalby ;
Botker, Hans Erik ;
Terkelsen, Christian Juhl ;
Villadsen, Anton Boel ;
Ravkilde, Jan ;
Aaroe, Jens ;
Madsen, Morten ;
Thuesen, Leif ;
Lassen, Jens Flensted .
LANCET, 2013, 381 (9867) :661-669
[2]   Evaluating the 'all-comers' design: a comparison of participants in two 'all-comers' PCI trials with non-participants [J].
de Boer, Sanneke P. M. ;
Lenzen, Mattie J. ;
Oemrawsingh, Rohit M. ;
Simsek, Cihan ;
Duckers, Henricus J. ;
van der Giessen, Willem J. ;
Serruys, Patrick W. ;
Boersma, Eric .
EUROPEAN HEART JOURNAL, 2011, 32 (17) :2161-2167
[3]   Long-term safety and efficacy of sirolimus-eluting stents versus bare-metal stents in real world clinical practice in Japan [J].
Kimura T. ;
Morimoto T. ;
Furukawa Y. ;
Nakagawa Y. ;
Kadota K. ;
Iwabuchi M. ;
Shizuta S. ;
Shiomi H. ;
Tada T. ;
Tazaki J. ;
Kato Y. ;
Hayano M. ;
Abe M. ;
Tamura T. ;
Shirotani M. ;
Miki S. ;
Matsuda M. ;
Takahashi M. ;
Ishii K. ;
Tanaka M. ;
Aoyama T. ;
Doi O. ;
Hattori R. ;
Tatami R. ;
Suwa S. ;
Takizawa A. ;
Takatsu Y. ;
Takahashi M. ;
Kato H. ;
Takeda T. ;
Lee J.-D. ;
Nohara R. ;
Ogawa H. ;
Tei C. ;
Horie M. ;
Kambara H. ;
Fujiwara H. ;
Mitsudo K. ;
Nobuyoshi M. ;
Kita T. .
Cardiovascular Intervention and Therapeutics, 2011, 26 (3) :234-245
[4]   Very Late Stent Thrombosis and Late Target Lesion Revascularization After Sirolimus-Eluting Stent Implantation Five-Year Outcome of the j-Cypher Registry [J].
Kimura, Takeshi ;
Morimoto, Takeshi ;
Nakagawa, Yoshihisa ;
Kawai, Kazuya ;
Miyazaki, Shunichi ;
Muramatsu, Toshiya ;
Shiode, Nobuo ;
Namura, Masanobu ;
Sone, Takahito ;
Oshima, Shigeru ;
Nishikawa, Hideo ;
Hiasa, Yoshikazu ;
Hayashi, Yasuhiko ;
Nobuyoshi, Masakiyo ;
Mitudo, Kazuaki .
CIRCULATION, 2012, 125 (04) :584-U111
[5]   Stent Thrombogenicity Early in High-Risk Interventional Settings Is Driven by Stent Design and Deployment and Protected by Polymer-Drug Coatings [J].
Kolandaivelu, Kumaran ;
Swaminathan, Rajesh ;
Gibson, William J. ;
Kolachalama, Vijaya B. ;
Nguyen-Ehrenreich, Kim-Lien ;
Giddings, Virginia L. ;
Coleman, Leslie ;
Wong, Gee K. ;
Edelman, Elazer R. .
CIRCULATION, 2011, 123 (13) :1400-1409
[6]   Stent thrombosis with drug-eluting and bare-metal stents: evidence from a comprehensive network meta-analysis [J].
Palmerini, Tullio ;
Biondi-Zoccai, Giuseppe ;
Della Riva, Diego ;
Stettler, Christoph ;
Sangiorgi, Diego ;
D'Ascenzo, Fabrizio ;
Kimura, Takeshi ;
Briguori, Carlo ;
Sabate, Manel ;
Kim, Hyo-Soo ;
De Waha, Antoinette ;
Kedhi, Elvin ;
Smits, Pieter C. ;
Kaiser, Christoph ;
Sardella, Gennaro ;
Marullo, Antonino ;
Kirtane, Ajay J. ;
Leon, Martin B. ;
Stone, Gregg W. .
LANCET, 2012, 379 (9824) :1393-1402
[7]   Abluminal biodegradable polymer biolimus-eluting stent versus durable polymer everolimus-eluting stent (COMPARE II): a randomised, controlled, non-inferiority trial [J].
Smits, Pieter Cornelis ;
Hofma, Sjoerd ;
Togni, Mario ;
Vazquez, Nicolas ;
Valdes, Mariano ;
Voudris, Vassilis ;
Slagboom, Ton ;
Goy, Jean-Jaques ;
Vuillomenet, Andre ;
Serra, Antoni ;
Trillo Nouche, Ramiro ;
den Heijer, Peter ;
van der Ent, Martin .
LANCET, 2013, 381 (9867) :651-660
[8]   Long-term clinical outcomes of biodegradable polymer biolimus-eluting stents versus durable polymer sirolimus-eluting stents in patients with coronary artery disease (LEADERS): 4 year follow-up of a randomised non-inferiority trial [J].
Stefanini, Giulio G. ;
Kalesan, Bindu ;
Serruys, Patrick W. ;
Heg, Dik ;
Buszman, Pawel ;
Linke, Axel ;
Ischinger, Thomas ;
Klauss, Volker ;
Eberli, Franz ;
Wijns, William ;
Morice, Marie-Claude ;
Di Mario, Carlo ;
Corti, Roberto ;
Antoni, Diethmar ;
Sohn, Hae Y. ;
Eerdmans, Pedro ;
van Es, Gerrit-Anne ;
Meier, Bernhard ;
Windecker, Stephan ;
Jueni, Peter .
LANCET, 2011, 378 (9807) :1940-1948