Evaluation of a Model-Based Hemodynamic Monitoring Method in a Porcine Study of Septic Shock

被引:10
作者
Revie, James A. [1 ]
Stevenson, David [1 ]
Chase, J. Geoffrey [1 ]
Pretty, Chris J. [1 ]
Lambermont, Bernard C. [2 ]
Ghuysen, Alexandre [2 ]
Kolh, Philippe [2 ]
Shaw, Geoffrey M. [3 ]
Desaive, Thomas [2 ]
机构
[1] Univ Canterbury, Ctr Bioengn, Dept Mech Engn, Christchurch 8140, New Zealand
[2] Univ Liege, Hemodynam Res Lab, Liege, Belgium
[3] Christchurch Hosp, Dept Intens Care, Christchurch, New Zealand
关键词
CENTRAL AORTIC PRESSURE; THORACIC ELECTRICAL BIOIMPEDANCE; PULMONARY VASCULAR-RESISTANCE; CARDIAC-OUTPUT MEASUREMENT; WAVE-FORM ANALYSIS; ENDOTOXIC-SHOCK; VENTRICULAR INTERACTION; SEVERE SEPSIS; SYSTEM MODEL; THERMODILUTION;
D O I
10.1155/2013/505417
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
Introduction. The accuracy and clinical applicability of an improved model-based system for tracking hemodynamic changes is assessed in an animal study on septic shock. Methods. This study used cardiovascular measurements recorded during a porcine trial studying the efficacy of large-pore hemofiltration for treating septic shock. Four Pietrain pigs were instrumented and induced with septic shock. A subset of the measured data, representing clinically available measurements, was used to identify subject-specific cardiovascular models. These models were then validated against the remaining measurements. Results. The system accurately matched independent measures of left and right ventricle end diastolic volumes and maximum left and right ventricular pressures to percentage errors less than 20% (except for the 95th percentile error in maximum right ventricular pressure) and all R-2 > 0.76. An average decrease of 42% in systemic resistance, a main cardiovascular consequence of septic shock, was observed 120 minutes after the infusion of the endotoxin, consistent with experimentally measured trends. Moreover, modelled temporal trends in right ventricular end systolic elastance and afterload tracked changes in corresponding experimentally derived metrics. Conclusions. These results demonstrate that this model-based method can monitor disease-dependent changes in preload, afterload, and contractility in porcine study of septic shock.
引用
收藏
页数:17
相关论文
共 50 条
[41]   Evaluation of Venous-to-Arterial Carbon Dioxide Tension Difference as a Complementary Parameter During Pediatric Septic Shock Resuscitation A Prospective Observational Study [J].
El-Nawawy, Ahmed Ahmed ;
Hassaan, Shimaa Mohammad ;
Hassouna, Hadir Mohamed .
PEDIATRIC EMERGENCY CARE, 2022, 38 (05) :201-206
[42]   Determinant Factors for Arterial Hemodynamics in Hypertension: Theoretical Insights From a Computational Model-Based Study [J].
Liang, Fuyou ;
Guan, Debao ;
Alastruey, Jordi .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2018, 140 (03)
[43]   Early Goal-Directed Therapy in Pediatric Septic Shock: Comparison of Outcomes "With" and "Without" Intermittent Superior Venacaval Oxygen Saturation Monitoring: A Prospective Cohort Study [J].
Sankar, Jhuma ;
Sankar, M. Jeeva ;
Suresh, C. P. ;
Dubey, Nandkishore K. ;
Singh, Archana .
PEDIATRIC CRITICAL CARE MEDICINE, 2014, 15 (04) :E157-E167
[44]   Integrated PERSEVERE and endothelial biomarker risk model predicts death and persistent MODS in pediatric septic shock: a secondary analysis of a prospective observational study [J].
Atreya, Mihir R. ;
Cvijanovich, Natalie Z. ;
Fitzgerald, Julie C. ;
Weiss, Scott L. ;
Bigham, Michael T. ;
Jain, Parag N. ;
Schwarz, Adam J. ;
Lutfi, Riad ;
Nowak, Jeffrey ;
Allen, Geoffrey L. ;
Thomas, Neal J. ;
Grunwell, Jocelyn R. ;
Baines, Torrey ;
Quasney, Michael ;
Haileselassie, Bereketeab ;
Lindsell, Christopher J. ;
Alder, Matthew N. ;
Wong, Hector R. .
CRITICAL CARE, 2022, 26 (01)
[45]   IDENTIFYING SEPTIC SHOCK POPULATIONS BENEFITTING FROM POLYMYXIN B HEMOPERFUSION: A PROSPECTIVE COHORT STUDY INCORPORATING A RESTRICTED CUBIC SPLINE REGRESSION MODEL [J].
Nakata, Hidekazu ;
Yamakawa, Kazuma ;
Kabata, Daijiro ;
Umemura, Yutaka ;
Ogura, Hiroshi ;
Gando, Satoshi ;
Shintani, Ayumi ;
Shiraishi, Atsushi ;
Saitoh, Daizoh ;
Fujishima, Seitaro ;
Mayumi, Toshihiko ;
Kushimoto, Shigeki ;
Abe, Toshikazu ;
Shiino, Yasukazu ;
Nakada, Taka-aki ;
Tarui, Takehiko ;
Hifumi, Toru ;
Otomo, Yasuhiro ;
Okamoto, Kohji ;
Kotani, Joji ;
Sakamoto, Yuichiro ;
Sasaki, Junichi ;
Shiraishi, Shin-ichiro ;
Takuma, Kiyotsugu ;
Tsuruta, Ryosuke ;
Hagiwara, Akiyoshi ;
Masuno, Tomohiko ;
Takeyama, Naoshi ;
Yamashita, Norio ;
Ikeda, Hiroto ;
Ueyama, Masashi ;
Fujimi, Satoshi .
SHOCK, 2020, 54 (05) :667-674
[46]   Comparison of fluid balance and hemodynamic and metabolic effects of sodium lactate versus sodium bicarbonate versus 0.9% NaCl in porcine endotoxic shock: a randomized, open-label, controlled study [J].
Duburcq, Thibault ;
Durand, Arthur ;
Dessein, Anne-Frederique ;
Vamecq, Joseph ;
Vienne, Jean-Claude ;
Dobbelaere, Dries ;
Mention, Karine ;
Douillard, Claire ;
Maboudou, Patrice ;
Gmyr, Valery ;
Pattou, Francois ;
Jourdain, Merce ;
Tamion, Fabienne ;
Poissy, Julien ;
Mathieu, Daniel ;
Favory, Raphael .
CRITICAL CARE, 2017, 21
[47]   Coagulation profiles in patients with sepsis/septic shock identify mixed hypo-hypercoagulation patterns based on rotational thromboelastometry: A prospective observational study [J].
Bui-Thi, Hanh-Duyen ;
Gia, Kien To ;
Minh, Khoi Le .
THROMBOSIS RESEARCH, 2023, 227 :51-59
[48]   Effects of Fluid Therapy on Mesenteric Microcirculation Using New Probe-Based Confocal Laser Endomicroscopy (Cellvizio®) in a Porcine Model of Endotoxic Shock [J].
Daniere, Charlotte ;
Louart, Guillaume ;
Louart, Benjamin ;
Bacle, Marylene ;
Bazalgette, Florian ;
Perez Martin, Antonia ;
Muller, Laurent ;
Lefrant, Jean-Yves ;
Roger, Claire .
JOURNAL OF VASCULAR RESEARCH, 2022, 59 (02) :124-134
[49]   Evaluation of Anticoagulation Practice With New-Onset Atrial Fibrillation in Patients with Sepsis and Septic Shock in Medical Intensive Care Unit: A Retrospective Observational Cohort Study [J].
Arunachalam, Karuppiah ;
Sundaram, Arvind Kalyan ;
Jha, Kunal ;
Thakur, Lokendra ;
Pond, Kyle .
CUREUS JOURNAL OF MEDICAL SCIENCE, 2020, 12 (08)
[50]   A Novel Mobile Phone Application for Pulse Pressure Variation Monitoring Based on Feature Extraction Technology: A Method Comparison Study in a Simulated Environment [J].
Desebbe, Olivier ;
Joosten, Alexandre ;
Suehiro, Koichi ;
Lahham, Sari ;
Essiet, Mfonobong ;
Rinehart, Joseph ;
Cannesson, Maxime .
ANESTHESIA AND ANALGESIA, 2016, 123 (01) :105-113