Evaluation of a Model-Based Hemodynamic Monitoring Method in a Porcine Study of Septic Shock

被引:10
作者
Revie, James A. [1 ]
Stevenson, David [1 ]
Chase, J. Geoffrey [1 ]
Pretty, Chris J. [1 ]
Lambermont, Bernard C. [2 ]
Ghuysen, Alexandre [2 ]
Kolh, Philippe [2 ]
Shaw, Geoffrey M. [3 ]
Desaive, Thomas [2 ]
机构
[1] Univ Canterbury, Ctr Bioengn, Dept Mech Engn, Christchurch 8140, New Zealand
[2] Univ Liege, Hemodynam Res Lab, Liege, Belgium
[3] Christchurch Hosp, Dept Intens Care, Christchurch, New Zealand
关键词
CENTRAL AORTIC PRESSURE; THORACIC ELECTRICAL BIOIMPEDANCE; PULMONARY VASCULAR-RESISTANCE; CARDIAC-OUTPUT MEASUREMENT; WAVE-FORM ANALYSIS; ENDOTOXIC-SHOCK; VENTRICULAR INTERACTION; SEVERE SEPSIS; SYSTEM MODEL; THERMODILUTION;
D O I
10.1155/2013/505417
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
Introduction. The accuracy and clinical applicability of an improved model-based system for tracking hemodynamic changes is assessed in an animal study on septic shock. Methods. This study used cardiovascular measurements recorded during a porcine trial studying the efficacy of large-pore hemofiltration for treating septic shock. Four Pietrain pigs were instrumented and induced with septic shock. A subset of the measured data, representing clinically available measurements, was used to identify subject-specific cardiovascular models. These models were then validated against the remaining measurements. Results. The system accurately matched independent measures of left and right ventricle end diastolic volumes and maximum left and right ventricular pressures to percentage errors less than 20% (except for the 95th percentile error in maximum right ventricular pressure) and all R-2 > 0.76. An average decrease of 42% in systemic resistance, a main cardiovascular consequence of septic shock, was observed 120 minutes after the infusion of the endotoxin, consistent with experimentally measured trends. Moreover, modelled temporal trends in right ventricular end systolic elastance and afterload tracked changes in corresponding experimentally derived metrics. Conclusions. These results demonstrate that this model-based method can monitor disease-dependent changes in preload, afterload, and contractility in porcine study of septic shock.
引用
收藏
页数:17
相关论文
共 50 条
[31]   Evaluation of Continuous Lactate Monitoring Systems within a Heparinized In Vivo Porcine Model Intravenously and Subcutaneously [J].
Wolf, Alexander ;
Renehan, Kevin ;
Ho, Kenneth K. Y. ;
Carr, Benjamin D. ;
Chen, Chieh V. ;
Cornell, Marie S. ;
Ye, Minyi ;
Rojas-Pena, Alvaro ;
Chen, Hao .
BIOSENSORS-BASEL, 2018, 8 (04)
[32]   A novel antibiotic based long-term model of ovine smoke inhalation injury and septic shock [J].
Nakano, Yoshimitsu ;
Maybauer, Marc O. ;
Maybauer, Dirk M. ;
Enkhbaatar, Perenlei ;
Traber, Daniel L. .
BURNS, 2010, 36 (07) :1050-1058
[33]   Association of Microcirculation, Macrocirculation, and Severity of Illness in Septic Shock: A Prospective Observational Study to Identify Microcirculatory Targets Potentially Suitable for Guidance of Hemodynamic Therapy [J].
Sturm, Timo ;
Leiblein, Julia ;
Schneider-Lindner, Verena ;
Kirschning, Thomas ;
Thiel, Manfred .
JOURNAL OF INTENSIVE CARE MEDICINE, 2018, 33 (04) :256-266
[34]   Utilization Patterns and Outcomes Associated With Central Venous Catheter in Septic Shock: A Population-Based Study [J].
Walkey, Allan J. ;
Wiener, Renda Soylemez ;
Lindenauer, Peter K. .
CRITICAL CARE MEDICINE, 2013, 41 (06) :1450-1457
[35]   Acute gastrointestinal failure is associated with worse hemodynamic and perfusion parameters over 48 h after admission in patients with septic shock: Retrospective cohort study [J].
Klanovicz, Tamires M. ;
Franzosi, Oellen S. ;
Nunes, Diego S. L. ;
Loss, Sergio H. ;
Batassini, Erica ;
Turra, Eduardo E. ;
Teixeira, Cassiano ;
Vieira, Silvia R. R. .
NUTRITION IN CLINICAL PRACTICE, 2023, 38 (03) :617-627
[36]   Evaluation of Early Corticosteroid Therapy in Management of Pediatric Septic Shock in Pediatric Intensive Care Patients A Randomized Clinical Study [J].
El-Nawawy, Ahmed ;
Khater, Doaa ;
Omar, Heba ;
Wali, Yasser .
PEDIATRIC INFECTIOUS DISEASE JOURNAL, 2017, 36 (02) :155-159
[37]   Clinically applicable model-based method, for physiologically accurate flow waveform and stroke volume estimation [J].
Balmer, Joel ;
Pretty, Christopher G. ;
Davidson, Shaun ;
Mehta-Wilson, Tashana ;
Desaive, Thomas ;
Smith, Rachel ;
Shaw, Geoffrey M. ;
Chase, J. Geoffrey .
COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2020, 185
[38]   Evaluation of Hyperviscous Fluid Resuscitation in a Canine Model of Hemorrhagic Shock: A Randomized, Controlled Study [J].
Cooper, Edward S. ;
Bateman, Shane W. ;
Muir, William W. .
JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2009, 66 (05) :1365-1373
[39]   Noninvasive cardiac output monitoring in a porcine model using the inspired sinewave technique: a proof-of-concept study [J].
Bruce, Richard M. ;
Crockett, Douglas C. ;
Morgan, Anna ;
Minh Cong Tran ;
Formenti, Federico ;
Phi Anh Phan ;
Farmery, Andrew D. .
BRITISH JOURNAL OF ANAESTHESIA, 2019, 123 (02) :126-134
[40]   Evaluation of Venous-to-Arterial Carbon Dioxide Tension Difference as a Complementary Parameter During Pediatric Septic Shock Resuscitation A Prospective Observational Study [J].
El-Nawawy, Ahmed Ahmed ;
Hassaan, Shimaa Mohammad ;
Hassouna, Hadir Mohamed .
PEDIATRIC EMERGENCY CARE, 2022, 38 (05) :201-206