Determination of compound-specific Hg isotope ratios from transient signals using gas chromatography coupled to multicollector inductively coupled plasma mass spectrometry (MC-ICP/MS)

被引:49
|
作者
Dzurko, Mark [1 ]
Foucher, Delphine [1 ]
Hintelmann, Holger [1 ]
机构
[1] Trent Univ, Peterborough, ON K9J 7B8, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
Multicollector inductively coupled plasma mass spectrometry; Mercury; Methylmercury; Isotope ratios; Transient signals; Speciation; Gas chromatography; Mass bias; Isotope fractionation; LEVEL ENVIRONMENTAL-SAMPLES; METHYL MERCURY-COMPOUNDS; DILUTION ANALYSIS; MS; PRECISION; FRACTIONATION; QUADRUPOLE; REDUCTION; SEDIMENTS; METHYLMERCURY;
D O I
10.1007/s00216-008-2165-y
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
MeHg and inorganic Hg compounds were measured in aqueous media for isotope ratio analysis using aqueous phase derivatization, followed by purge-and-trap preconcentration. Compound-specific isotope ratio measurements were performed by gas chromatography interfaced to MC-ICP/MS. Several methods of calculating isotope ratios were evaluated for their precision and accuracy and compared with conventional continuous flow cold vapor measurements. An apparent fractionation of Hg isotopes was observed during the GC elution process for all isotope pairs, which necessitated integration of signals prior to the isotope ratio calculation. A newly developed average peak ratio method yielded the most accurate isotope ratio in relation to values obtained by a continuous flow technique and the best reproducibility. Compound-specific isotope ratios obtained after GC separation were statistically not different from ratios measured by continuous flow cold vapor measurements. Typical external uncertainties were 0.16aEuro degrees RSD (n = 8) for the (202)Hg(/198)Hg ratio of MeHg and 0.18aEuro degrees RSD for the same ratio in inorganic Hg using the optimized operating conditions. Using a newly developed reference standard addition method, the isotopic composition of inorganic Hg and MeHg synthesized from this inorganic Hg was measured in the same run, obtaining a value of delta (202)Hg = -1.49 +/- 0.47 (2SD; n = 10). For optimum performance a minimum mass of 2 ng per Hg species should be introduced onto the column.
引用
收藏
页码:345 / 355
页数:11
相关论文
共 50 条
  • [41] A multinebulization technique for the determination of trace metals in a marine biota sample by on-line isotope dilution inductively coupled plasma mass spectrometry (OID-ICP-MS)
    Garcia, Miriam
    Angel Aguirre, Miguel
    Vassileva, Emilia
    Canals, Antonio
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2020, 35 (11) : 2509 - 2516
  • [42] Determination of 241Am in sediments by isotope dilution high resolution inductively coupled plasma mass spectrometry (ID HR ICP-MS)
    Agarande, M
    Benzoubir, S
    Bouisset, P
    Calmet, D
    APPLIED RADIATION AND ISOTOPES, 2001, 55 (02) : 161 - 165
  • [43] Isotope ratio measurement of uranium in safeguards environmental samples by inductively-coupled plasma mass spectrometry (ICP-MS)
    Magara, M
    Sakakibara, T
    Kurosawa, S
    Takahashi, M
    Sakurai, S
    Hanzawa, Y
    Esaka, F
    Watanabe, K
    Usuda, SE
    JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY, 2002, 39 (04) : 308 - 311
  • [44] PRECISE DETERMINATION OF IRON ISOTOPE RATIOS IN WHOLE-BLOOD USING INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY - INVITED LECTURE
    WHITTAKER, PG
    BARRETT, JFR
    WILLIAMS, JG
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1992, 7 (02) : 109 - 115
  • [45] Validation, using a chemometric approach, of gas chromatography–inductively coupled plasma–atomic emission spectrometry (GC–ICP–AES) for organotin determination
    Sandrine Aguerre
    Christophe Pécheyran
    Gaëtane Lespes
    Analytical and Bioanalytical Chemistry, 2003, 376 : 226 - 235
  • [46] High-precision measurement of mercury isotope ratios in sediments using cold-vapor generation multi-collector inductively coupled plasma mass spectrometry
    Delphine Foucher
    Holger Hintelmann
    Analytical and Bioanalytical Chemistry, 2006, 384 : 1470 - 1478
  • [47] Application of high performance liquid chromatography with inductively coupled plasma mass spectrometry (HPLC-ICP-MS) for determination of chromium compounds in the air at the workplace
    Stanislawska, Magdalena
    Janasik, Beata
    Wasowicz, Wojciech
    TALANTA, 2013, 117 : 14 - 19
  • [48] Determination of cobalt compounds in dietary supplements using liquid chromatography inductively coupled plasma mass spectrometry
    Wu, Che-Wei
    Jiang, Shiuh-Jen
    Sahayam, A. C.
    Huang, Yeou-Lih
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2019, 154 : 70 - 74
  • [49] Comparison of the Application of High-Resolution Inductively Coupled Plasma Mass Spectrometry (HR-ICP-MS) and Collision/Reaction Cell Technology of Inductively Coupled Plasma Mass Spectrometry (ICP-CCT-MS) in the Determination of Selenium in Coal-Bearing Strata
    Zhao, Shumao
    Jia, Rongkun
    Han, Qiuchan
    Shang, Niande
    Teng, Kaiyan
    Feng, Jiawei
    MINERALS, 2024, 14 (05)
  • [50] Comparison of different mass bias correction procedures for the measurement of mercury species-specific isotopic composition by gas chromatography coupled to multicollector ICP-MS
    Suarez-Criado, Laura
    Queipo-Abad, Silvia
    Rodriguez-Gonzalez, Pablo
    Garcia Alonso, Jose Ignacio
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2024, 39 (02) : 508 - 517