Determination of compound-specific Hg isotope ratios from transient signals using gas chromatography coupled to multicollector inductively coupled plasma mass spectrometry (MC-ICP/MS)

被引:49
|
作者
Dzurko, Mark [1 ]
Foucher, Delphine [1 ]
Hintelmann, Holger [1 ]
机构
[1] Trent Univ, Peterborough, ON K9J 7B8, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
Multicollector inductively coupled plasma mass spectrometry; Mercury; Methylmercury; Isotope ratios; Transient signals; Speciation; Gas chromatography; Mass bias; Isotope fractionation; LEVEL ENVIRONMENTAL-SAMPLES; METHYL MERCURY-COMPOUNDS; DILUTION ANALYSIS; MS; PRECISION; FRACTIONATION; QUADRUPOLE; REDUCTION; SEDIMENTS; METHYLMERCURY;
D O I
10.1007/s00216-008-2165-y
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
MeHg and inorganic Hg compounds were measured in aqueous media for isotope ratio analysis using aqueous phase derivatization, followed by purge-and-trap preconcentration. Compound-specific isotope ratio measurements were performed by gas chromatography interfaced to MC-ICP/MS. Several methods of calculating isotope ratios were evaluated for their precision and accuracy and compared with conventional continuous flow cold vapor measurements. An apparent fractionation of Hg isotopes was observed during the GC elution process for all isotope pairs, which necessitated integration of signals prior to the isotope ratio calculation. A newly developed average peak ratio method yielded the most accurate isotope ratio in relation to values obtained by a continuous flow technique and the best reproducibility. Compound-specific isotope ratios obtained after GC separation were statistically not different from ratios measured by continuous flow cold vapor measurements. Typical external uncertainties were 0.16aEuro degrees RSD (n = 8) for the (202)Hg(/198)Hg ratio of MeHg and 0.18aEuro degrees RSD for the same ratio in inorganic Hg using the optimized operating conditions. Using a newly developed reference standard addition method, the isotopic composition of inorganic Hg and MeHg synthesized from this inorganic Hg was measured in the same run, obtaining a value of delta (202)Hg = -1.49 +/- 0.47 (2SD; n = 10). For optimum performance a minimum mass of 2 ng per Hg species should be introduced onto the column.
引用
收藏
页码:345 / 355
页数:11
相关论文
共 50 条
  • [31] A Novel Approach for the Determination of the Ge Isotope Ratio Using Liquid-Liquid Extraction and Hydride Generation by Multicollector Inductively Coupled Plasma Mass Spectrometry
    Karasinski, Jakub
    Tupys, Andrii
    Halicz, Ludwik
    Bulska, Ewa
    ANALYTICAL CHEMISTRY, 2021, 93 (40) : 13548 - 13554
  • [32] Investigation of metallodrug-protein interactions by size-exclusion chromatography coupled with inductively coupled plasma mass spectrometry (ICP-MS)
    Szpunar, J
    Makarov, A
    Pieper, T
    Keppler, BK
    Lobinski, R
    ANALYTICA CHIMICA ACTA, 1999, 387 (02) : 135 - 144
  • [33] Detection of counterfeit antiviral drug Heptodin™ and classification of counterfeits using isotope amount ratio measurements by multicollector inductively coupled plasma mass spectrometry (MC-ICPMS) and isotope ratio mass spectrometry (IRMS)
    Santamaria-Fernandez, Rebeca
    Hearn, Ruth
    Wolff, Jean-Claude
    SCIENCE & JUSTICE, 2009, 49 (02) : 102 - 106
  • [34] Determination of Cr(VI) in rice using ion chromatography inductively coupled plasma mass spectrometry
    Chen, Bo-Hao
    Jiang, Shiuh-Jen
    Sahayam, A. C.
    FOOD CHEMISTRY, 2020, 324
  • [35] Matrix and energy effects during in-situ determination of Cu isotope ratios by ultraviolet-femtosecond laser ablation multicollector inductively coupled plasma mass spectrometry
    Lazarov, Marina
    Horn, Ingo
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2015, 111 : 64 - 73
  • [36] Simultaneous speciation analysis of mercury in marine origin samples by high performance liquid chromatography and species - specific isotope dilution inductively coupled plasma mass spectrometry
    Krata, Agnieszka Anna
    Vassileva, Emilia
    TALANTA, 2020, 217 (217)
  • [37] An online internal standard technique for high-performance liquid chromatography-inductively coupled plasma mass spectrometry (HPLC-ICP-MS)
    Narukawa, Tomohiro
    Suzuki, Toshihiro
    Okabayashi, Satoki
    Chiba, Koichi
    ANALYTICAL METHODS, 2023, 15 (02) : 240 - 246
  • [38] High Precision Determination of Mercury Isotope Ratios Using Online Mercury Vapor Generation System Coupled with Multi-collector Inductively Coupled Plasma-Mass Spectrometry
    Yin Run-Sheng
    Feng Xin-Bin
    Foucher, Delphine
    Shi Wen-Fang
    Zhao Zhi-Qi
    Wang Jing
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2010, 38 (07) : 929 - 934
  • [39] Determination of Trace Elements in Mushrooms by Inductively Coupled Plasma - Mass Spectrometry (ICP-MS): Characterization of the Health Risk
    Dimitrijevic, Marija
    Nikolic, Jelena
    Mitic, Violeta
    Stankov Jovanovic, Vesna
    Miladinovic, Dragoljub
    ANALYTICAL LETTERS, 2023, 56 (13) : 2201 - 2214
  • [40] Determination of Uranium Isotope Ratios in Uranium Particles by Laser Ablation Multiple Collector Inductively Coupled Plasma Mass Spectrometry
    Wang Wei
    Li Zhi-Ming
    Xu Jiang
    Zhou Guo-Qing
    Shen Xiao-Pan
    Zhai Li-Hua
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2015, 43 (05) : 703 - 708