Determination of compound-specific Hg isotope ratios from transient signals using gas chromatography coupled to multicollector inductively coupled plasma mass spectrometry (MC-ICP/MS)

被引:49
|
作者
Dzurko, Mark [1 ]
Foucher, Delphine [1 ]
Hintelmann, Holger [1 ]
机构
[1] Trent Univ, Peterborough, ON K9J 7B8, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
Multicollector inductively coupled plasma mass spectrometry; Mercury; Methylmercury; Isotope ratios; Transient signals; Speciation; Gas chromatography; Mass bias; Isotope fractionation; LEVEL ENVIRONMENTAL-SAMPLES; METHYL MERCURY-COMPOUNDS; DILUTION ANALYSIS; MS; PRECISION; FRACTIONATION; QUADRUPOLE; REDUCTION; SEDIMENTS; METHYLMERCURY;
D O I
10.1007/s00216-008-2165-y
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
MeHg and inorganic Hg compounds were measured in aqueous media for isotope ratio analysis using aqueous phase derivatization, followed by purge-and-trap preconcentration. Compound-specific isotope ratio measurements were performed by gas chromatography interfaced to MC-ICP/MS. Several methods of calculating isotope ratios were evaluated for their precision and accuracy and compared with conventional continuous flow cold vapor measurements. An apparent fractionation of Hg isotopes was observed during the GC elution process for all isotope pairs, which necessitated integration of signals prior to the isotope ratio calculation. A newly developed average peak ratio method yielded the most accurate isotope ratio in relation to values obtained by a continuous flow technique and the best reproducibility. Compound-specific isotope ratios obtained after GC separation were statistically not different from ratios measured by continuous flow cold vapor measurements. Typical external uncertainties were 0.16aEuro degrees RSD (n = 8) for the (202)Hg(/198)Hg ratio of MeHg and 0.18aEuro degrees RSD for the same ratio in inorganic Hg using the optimized operating conditions. Using a newly developed reference standard addition method, the isotopic composition of inorganic Hg and MeHg synthesized from this inorganic Hg was measured in the same run, obtaining a value of delta (202)Hg = -1.49 +/- 0.47 (2SD; n = 10). For optimum performance a minimum mass of 2 ng per Hg species should be introduced onto the column.
引用
收藏
页码:345 / 355
页数:11
相关论文
共 50 条
  • [1] Determination of compound-specific Hg isotope ratios from transient signals using gas chromatography coupled to multicollector inductively coupled plasma mass spectrometry (MC-ICP/MS)
    Mark Dzurko
    Delphine Foucher
    Holger Hintelmann
    Analytical and Bioanalytical Chemistry, 2009, 393
  • [2] Measurement of compound-specific Hg isotopic composition in narrow transient signals by gas chromatography coupled to multicollector ICP-MS
    Queipo-Abad, Silvia
    Rodriguez-Gonzalez, Pablo
    Garcia Alonso, Jose Ignacio
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2019, 34 (04) : 753 - 763
  • [3] Hg Compound-Specific Isotope Analysis at Ultratrace Levels Using an on Line Gas Chromatographic Preconcentration and Separation Strategy Coupled to Multicollector-Inductively Coupled Plasma Mass Spectrometry
    Bouchet, Sylvain
    Berail, Sylvain
    Amouroux, David
    ANALYTICAL CHEMISTRY, 2018, 90 (13) : 7809 - 7816
  • [4] Simplified technique for the measurements of Re-Os isotope by multicollector inductively coupled plasma mass spectrometry (MC-ICP-MS)
    Li, Jie
    Liang, Xi-rong
    Xu, Ji-feng
    Suzuki, Katsuhiko
    Dong, Yan-hui
    GEOCHEMICAL JOURNAL, 2010, 44 (01) : 73 - 80
  • [5] Determination of tin isotope ratios in cassiterite by femtosecond laser ablation multicollector inductively coupled plasma mass spectrometry
    Schulze, Marie
    Ziegerick, Marco
    Horn, Ingo
    Weyer, Stefan
    Vogt, Carla
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2017, 130 : 26 - 34
  • [6] Serum/plasma methylmercury determination by isotope dilution gas chromatography-inductively coupled plasma mass spectrometry
    Baxter, Douglas C.
    Faarinen, Mikko
    Osterlund, Helene
    Rodushkin, Ilia
    Christensen, Morten
    ANALYTICA CHIMICA ACTA, 2011, 701 (02) : 134 - 138
  • [7] Compound-specific bromine isotope analysis of methyl bromide using gas chromatography hyphenated with inductively coupled plasma multiple-collector mass spectrometry
    Horst, Axel
    Holmstrand, Henry
    Andersson, Per
    Andersson, August
    Carrizo, Daniel
    Thornton, Brett F.
    Gustafsson, Orjan
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2011, 25 (17) : 2425 - 2432
  • [8] A Validated Routine Method for Butyltin Determination in Seafood by Gas Chromatography Inductively Coupled Plasma Isotope Dilution Mass Spectrometry
    Valdersnes, Stig
    Solli, Berit
    Sele, Veronika
    Julshamn, Kare
    JOURNAL OF AOAC INTERNATIONAL, 2019, 102 (01) : 278 - 285
  • [9] Liquid chromatography - Inductively coupled plasma mass spectrometry (LC-ICP-MS)
    Wang, Tiebang
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2007, 30 (5-8) : 807 - 831
  • [10] Improvements on high-precision measurement of bromine isotope ratios by multicollector inductively coupled plasma mass spectrometry
    Wei, Hai-Zhen
    Jiang, Shao-Yong
    Zhu, Zhi-Yong
    Yang, Tao
    Yang, Jing-Hong
    Yan, Xiong
    Wu, He-Pin
    Yang, Tang-Li