Assessment of left ventricular cardiac output by arterial thermodilution technique via a left atrial catheter in a patient on a right ventricular assist device

被引:5
作者
Wiesenack, C [1 ]
Prasser, C [1 ]
Liebold, A [1 ]
Schmid, FX [1 ]
机构
[1] Univ Hosp Regensburg, Dept Anaesthesia, D-93052 Regensburg, Germany
来源
PERFUSION-UK | 2004年 / 19卷 / 01期
关键词
D O I
10.1191/0267659104pf698oa
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Following heart transplantation (HTx) in a 49-year old male, the patient's haemodynamic situation deteriorated in the early postoperative period despite increasing doses of catecholamines. When transoesophageal echocardiography ( TEE) showed a dilated right ventricle, but adequate left ventricular (LV) function, a right ventricular assist device (RVAD) was implanted to support the right ventricle of the failing graft. Evaluation of the resulting cardiac output (CO) of the left ventricle and, thus, assessment of the remaining right ventricular function in patients supported by a RVAD is of great clinical interest. In this situation, continuous measurement of LV function, enabling assessment of the remaining right ventricular function, can be performed by pulse contour analysis following initial calibration of the system by arterial thermodilution CO measurement via a left atrial catheter.
引用
收藏
页码:73 / 75
页数:3
相关论文
共 16 条
  • [1] MECHANICAL VENTRICULAR ASSISTANCE FOR THE FAILING RIGHT VENTRICLE AFTER CARDIAC TRANSPLANTATION
    BARNARD, SP
    HASAN, A
    FORTY, J
    HILTON, CJ
    DARK, JH
    [J]. EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 1995, 9 (06) : 297 - 299
  • [2] BOURGE RC, 1993, J HEART LUNG TRANSPL, V12, P549
  • [3] Experience with right ventricular assist devices for perioperative right sided circulatory failure
    Chen, JM
    Levin, HR
    Rose, EA
    Addonizio, LJ
    Landry, DW
    Sistino, JJ
    Michler, RE
    Oz, MC
    [J]. ANNALS OF THORACIC SURGERY, 1996, 61 (01) : 305 - 310
  • [4] Levosimendan: a new era for inodilator therapy for heart failure?
    Cleland, JGF
    McGowan, J
    [J]. CURRENT OPINION IN CARDIOLOGY, 2002, 17 (03) : 257 - 265
  • [5] Transesophageal echocardiographic evaluation of patients receiving mechanical assistance from ventricular assist devices
    DavilaRoman, VG
    Barzilai, B
    [J]. ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 1997, 14 (05): : 505 - 511
  • [6] LEFT-VENTRICULAR DERIVED CARDIAC-OUTPUT
    FRENCH, WJ
    HASKELL, RJ
    KNOUSE, RW
    CRILEY, JM
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1987, 59 (01) : 142 - 144
  • [7] Continuous cardiac output by femoral arterial thermodilution calibrated pulse contour analysis: Comparison with pulmonary arterial thermodilution
    Goedje, O
    Hoeke, K
    Lichtwarck-Aschoff, M
    Faltchauser, A
    Lamm, P
    Reichart, B
    [J]. CRITICAL CARE MEDICINE, 1999, 27 (11) : 2407 - 2412
  • [8] KIELERJENSEN N, 1993, J HEART LUNG TRANSPL, V12, P179
  • [9] KIELERJENSEN N, 1995, J HEART LUNG TRANSPL, V14, P436
  • [10] Radovancevic B, 1989, ASAIO Trans, V35, P539, DOI 10.1097/00002480-198907000-00118