Distal Femoral Fractures in Post-poliomyelitis Patients Treated with Locking Compression Plates

被引:9
|
作者
Wang, Wei-jun [1 ]
Shi, Hong-fei [1 ]
Chen, Dong-yang [1 ]
Chen, Yi-xin [1 ]
Wang, Jun-fei [1 ]
Wang, Shou-feng [1 ]
Qiu, Yong [1 ]
Xiong, Jin [1 ]
机构
[1] Nanjing Univ, Dept Orthopaed, Affiliated Drum Tower Hosp, Sch Med, Nanjing 210008, Jiangsu, Peoples R China
关键词
Femur; Internal fixation; Osteopenia; Poliomyelitis; KNEE FLEXION CONTRACTURE; DYNAMIC CONDYLAR SCREW; INTERNAL-FIXATION; FEMUR FRACTURES; OLMSTED-COUNTY; OSTEOSYNTHESIS; FALLS; POLIOMYELITIS; OSTEOPOROSIS; OSTEOTOMY;
D O I
10.1111/os.12035
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objective: Treatment of distal femoral fracture in post-polio patients is difficult because the bone is usually osteopenic, small and deformed. This retrospective study aimed to investigate the outcomes of distal femoral fracture in post-polio patients treated by locking compression plates (LCP). Methods: The medical records of 19 post-polio patients (mean age 49 years at time of surgery) were reviewed and intraoperative data retrieved. Fracture union and callus formation were evaluated on radiographs taken at each postoperative visit. Functional outcome assessments included range of motion and Hospital for Special Surgery (HSS) score of the ipsilateral knee joint. Results: Sixteen femoral fractures occurred in the poliomyelitis-affected limbs. The mean duration of operation was 86 min and mean blood loss 120 mL. All fractures healed (mean, four months) but union was delayed in one. At the final follow-up 2 yrs after surgery, the mean range of knee flexion was 105 degrees (range, 90 degrees-130 degrees), and mean HSS score 76 points (range, 60-93). There were no cases of nonunion, implant cutout, or other complications. Conclusions: LCP provides stable fixation of distal femoral fractures in post-polio patients. Bony union and good functional outcomes are achieved, but delayed union and minimal callus may occur.
引用
收藏
页码:118 / 123
页数:6
相关论文
共 50 条
  • [41] Prospective Evaluation of Distal Radius Fractures Treated With Variable-Angle Volar Locking Plates
    Fowler, John R.
    Ilyas, Asif M.
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2013, 38A (11): : 2198 - 2203
  • [42] Analysis of risk factors for revision in distal femoral fractures treated with lateral locking plate: a retrospective study in Chinese patients
    Hou, Guojin
    Zhou, Fang
    Tian, Yun
    Ji, Hongquan
    Zhang, Zhishan
    Guo, Yan
    Lv, Yang
    Yang, Zhongwei
    Zhang, Yawen
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2020, 15 (01)
  • [43] Retrograde intramedullary nails with distal screws locked to the nail have higher fatigue strength than locking plates in the treatment of supracondylar femoral fractures A CADAVER-BASED LABORATORY INVESTIGATION
    Pekmezci, M.
    McDonald, E.
    Buckley, J.
    Kandemir, U.
    BONE & JOINT JOURNAL, 2014, 96B (01) : 114 - 121
  • [44] Treatment of distal humerus fractures with LCP DHP™ locking plates in patients older than 65 years
    Ducrot, G.
    Bonnomet, F.
    Adam, P.
    Ehlinger, M.
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2013, 99 (02) : 145 - 154
  • [45] Application of distal femoral 90° locking plate in children with supracondylar femoral fractures
    Zhang, Y. -J.
    Wang, Y. -J.
    Wang, S. -H.
    Song, X. -L.
    Zhao, N.
    EUROPEAN REVIEW FOR MEDICAL AND PHARMACOLOGICAL SCIENCES, 2023, 27 (17) : 7956 - 7967
  • [46] PALMAR FIXATION OF DORSALLY DISPLACED DISTAL RADIUS FRACTURES USING LOCKING PLATES WITH SMARTLOCK LOCKING SCREWS
    Wong, T. C.
    Yeung, C. C.
    Chiu, Y.
    Yeung, S. H.
    Ip, F. K.
    JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2009, 34E (02) : 173 - 178
  • [47] Combination of anatomical locking plate and retrograde intramedullary nail in distal femoral fractures: comparison of mechanical stability
    Basci, Onur
    Karakasli, Ahmet
    Kumtepe, Erdem
    Guran, Orta
    Havitcioglu, Hasan
    EKLEM HASTALIKLARI VE CERRAHISI-JOINT DISEASES AND RELATED SURGERY, 2015, 26 (01): : 21 - 26
  • [48] Fractures of the Distal Tibia Treated with Polyaxial Locking Plating
    Gao, Hong
    Zhang, Chang-Qing
    Luo, Cong-Feng
    Zhou, Zu-Bin
    Zeng, Bing-Fang
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2009, 467 (03) : 831 - 837
  • [49] Locking versus non-locking one-third tubular plates for treating osteoporotic distal fibula fractures: a comparative study
    Herrera-Perez, Mario
    Gutierrez-Morales, Maria J.
    Guerra-Ferraz, Ayron
    Pais-Brito, Jose L.
    Boluda-Mengod, Juan
    Garces, Gerardo L.
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2017, 48 : S60 - S65
  • [50] Locking compression plate as an external fixator in the treatment of closed distal tibial fractures
    Zhou, Yu
    Wang, Yanbiao
    Liu, Lifeng
    Zhou, Zhenyu
    Cao, Xuecheng
    INTERNATIONAL ORTHOPAEDICS, 2015, 39 (11) : 2227 - 2237