Study of protection of transformer from very fast transient over-voltage in 750kV GIS

被引:0
|
作者
Liu, Q [1 ]
机构
[1] Xian Jiaotong Univ, Sch Elect Engn, Xian 710049, Peoples R China
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Gas Insulated Switchgears, also called Gas Insulated Substation, is applied to power system widely. Running experiences have shown that switching operations will generate Very Fast Transient Over-voltage, which has steep front and is followed by high frequency oscillations. VFTO spreads out of GIS and endangers the equipments connected to GIS. The transformer is the main casualty of VFTO. In this paper a 750kV GIs system has been set up. VFTO at the transformer terminal of different running modes have been calculated using Electro-Magnetic Transient Program (EMTP). This paper has studied the protective effect of shunt resistor of the switches, MOA and R-C surge suppresser. From a large amount of simulated calculations by Electro-Magnetic Transient Program, it can be found that the shunt resistors could accelerate the attenuation of over-voltages, so the peak and gradient reduce greatly. MOA only has effect on the peak value, whereas has no effect on the gradient. R-C surge suppresser not only could limit the peak of VFTO, but also could reduce its gradient. The effect of R-C surge suppresser is better than MOA, if the values of the resistor and the capacitor are selected suitably.
引用
收藏
页码:2153 / 2156
页数:4
相关论文
共 50 条
  • [41] The Fast Over-voltage Protection Consideration and Design for SiC-based Matrix Converters
    Costa, Louelson A.
    Fan, Boran
    Burgos, Rolando
    Boroyevich, Dushan
    Chen, Warren
    Blasko, Vladimir
    2020 THIRTY-FIFTH ANNUAL IEEE APPLIED POWER ELECTRONICS CONFERENCE AND EXPOSITION (APEC 2020), 2020, : 1567 - 1574
  • [42] Comparison and Analysis on Very Fast Transient Overvoltage Based on 550kV GIS and 800kV GIS
    Tian Chi
    Lin Xin
    Xu Jianyuan
    Geng Zhen-xin
    ICHVE 2008: 2008 INTERNATIONAL CONFERENCE ON HIGH VOLTAGE ENGINEERING AND APPLICATION, 2008, : 288 - 291
  • [43] Research On The Over-voltage of 220kV Power System Caused by Traction Transformer's Commissioning
    Ma Weiping
    Cheng Fangxiao
    Zhou Wenjun
    2009 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), VOLS 1-7, 2009, : 1817 - +
  • [44] Computation and Protection Measures of Very Fast Transient Overvoltages in Large Transformer Windings
    Mao Y.
    Cai X.
    Yang Y.
    Gaodianya Jishu/High Voltage Engineering, 2019, 45 (03): : 975 - 982
  • [45] TRANSIENT OVER-VOLTAGE PROTECTION IN METAL-CLAD SF6-INSULATED SUBSTATIONS
    ANDERSEN, BR
    SIMMS, JR
    GEC-JOURNAL OF SCIENCE & TECHNOLOGY, 1983, 49 (01): : 23 - 28
  • [46] A Review of the GIS Very Fast Transient Overvoltage Characteristics Study
    Li, Zhongyang
    Che, Chuanqiang
    Feng, Ruming
    Qin, Chunxu
    PROCEEDINGS OF THE 4TH INTERNATIONAL SYMPOSIUM ON NEW ENERGY AND ELECTRICAL TECHNOLOGY, ISNEET 2023, 2024, 1255 : 447 - 452
  • [47] Study on anti-interference and over-voltage protection of dispatching automation devices
    Li, Peng
    Chen, Jialin
    Jin, Bo
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 1999, 23 (19): : 60 - 62
  • [48] A Modeling for Transformer Windings under Very Fast Transient Over-voltages
    Zhang, Ping
    Wang, You-hua
    Nie, Xin-peng
    Yan, Wei-li
    Zhang, Hai-jiao
    ICEMS 2008: PROCEEDINGS OF THE 11TH INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES AND SYSTEMS, VOLS 1- 8, 2008, : 4309 - +
  • [49] Computation of Very Fast Transient Over-voltages (VFTO) in Transformer Windings
    Gao Youhua
    Li Yanbin
    Ding Chunhong
    Wang Guogang
    2009 INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES AND SYSTEMS, VOLS 1-3, 2009, : 452 - +
  • [50] A high-frequency circuit model of a potential transformer for the very fast transient simulation in GIS
    Zhang Zhonyuan
    Lu Fangcheng
    Liang Guishu
    IEEE TRANSACTIONS ON POWER DELIVERY, 2008, 23 (04) : 1995 - 1999