Hydrothermal polycrystalline PZT thick film transducer for high intensity ultrasound radiation at over 20 MHz

被引:0
|
作者
Ishikawa, Mutsuo [1 ]
Kurosawa, Minoru Kuribayashi [1 ]
Endoh, Akito [2 ]
Uchida, Takeyoshi [2 ]
Takeuchi, Shinichi [2 ]
机构
[1] Tokyo Inst Technol, Interdisciplinary Grad Sch Sci & Engn, Midori Ku, Yokohama, Kanagawa 227, Japan
[2] Toin Univ Yokohama, Fac Engn, Yokohama, Kanagawa, Japan
来源
2006 IEEE ULTRASONICS SYMPOSIUM, VOLS 1-5, PROCEEDINGS | 2006年
关键词
hydrothermal thick film; piezoelectric material; ultrasonic transducer; high frequency; high intensity radiation;
D O I
暂无
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
A high intensity and high frequency ultrasound radiation ultrasonic transducer was fabricated by the hydrothermal deposition technique of lead zirconate titanate polycrystalline thick film. This ultrasonic transducer had a 45 micron meters thick hydrothermal PZT layer on a 50 micron meters thick titanium substrate, and an active area was 5 mm X 5 mm. The piezoelectric constant d33 of this PZT thick film was 44 pm/V and the acoustic impedance was about 8 Mrayl. This prototype ultrasonic transducer radiated a sound pressures of over 100 kPa at over 20 MHz in degassed water using a thickness vibration mode of the PZT film. The radiated sound pressures was measured using a commercial hydrophone that was proofed of the receiving sensitivity at 1 MHz to 60 MHz. The hydrophone was held 40 mm in front of a surface of the prototype transducer. This measuring point was a central ultrasonic beam axis from the prototype transducer. An applied voltage to the prototype ultrasonic transducer was 40 V at ten cycles burst waveform of sine wave when measuring the radiated sound pressure. Additionally, when a driving signal was 20 MHz continuous sine waves, cavitations and an acoustic streaming was generated along a line of the central ultrasonic beam axis. The observation of generated cavitations when the continuous high intensity ultrasonic radiation from the transducer was conducted with the KI oxidation method. The cavitations was measured by measuring the oxidation reaction from the generating of cavitations in a KI solution. A volume of the KI solution for the measurement of cavitations was 50 ml.
引用
收藏
页码:2369 / +
页数:2
相关论文
共 26 条
  • [1] Hydrothermal PZT thick film ultrasonic transducer for 2 to 40 MHz frequency band
    Ishikawa, M
    Kurosawa, MK
    Hasegawa, T
    Endoh, A
    Takeuchi, S
    2005 IEEE Ultrasonics Symposium, Vols 1-4, 2005, : 2231 - 2234
  • [2] PZT epitaxial thick film for ultrasonic transducer at frequencies below 100 MHz
    Mazda, Yuka
    Shimidzu, Takahiro
    Yanagitani, Takahiko
    2018 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2018,
  • [3] Characterization of Hydrophone with Hydrothermal PZT Thick Film Vibrator and Ti Front Layer for Measurement in High Intensity Therapeutic Ultrasound
    Okada, Nagaya
    Asakura, Yoshiyuki
    Shiiba, Michihisa
    Takeuchi, Shinichi
    Uchida, Takeyoshi
    Yoshioka, Masahiro
    Kikuchi, Tsuneo
    Kurosawa, Minoru K.
    2013 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2013, : 1113 - 1116
  • [4] Performance of hydrothermal PZT film on high intensity operation
    Kanda, T
    Kurosawa, MK
    Yasui, H
    Higuchi, T
    SENSORS AND ACTUATORS A-PHYSICAL, 2001, 89 (1-2) : 16 - 21
  • [5] Study on optimizing ultrasonic irradiation period for thick polycrystalline PZT film by hydrothermal method
    Ohta, Kanako
    Isobe, Gaku
    Bornmann, Peter
    Hemsel, Tobias
    Morita, Takeshi
    ULTRASONICS, 2013, 53 (04) : 837 - 841
  • [6] Lead zirconate titanate thick-film ultrasonic transducer for 1 to 20 MHz frequency bands fabricated by hydrothermal polycrystal growth
    Ishikawa, M
    Kurosawa, MK
    Endoh, A
    Takeuchi, S
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS BRIEF COMMUNICATIONS & REVIEW PAPERS, 2005, 44 (6B): : 4342 - 4346
  • [7] THICK SCALN FILM FOR HIGH EFFICIENT ULTRASONIC TRANSDUCER IN LOW FREQUENCY OF 81 MHZ
    Sano, Ko-hei
    Karasawa, Rei
    Yanagitani, Takahiko
    2017 19TH INTERNATIONAL CONFERENCE ON SOLID-STATE SENSORS, ACTUATORS AND MICROSYSTEMS (TRANSDUCERS), 2017, : 862 - 865
  • [8] Effect on High-Intensity Fields of a Tough Hydrophone With Hydrothermal PZT Thick-Film Vibrator and Titanium Front Layer
    Okada, Nagaya
    Takeuchi, Shinichi
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2017, 64 (07) : 1120 - 1126
  • [9] Prototyping of a High Frequency Phased Array Ultrasound Transducer on a Piezoelectric Thick Film
    Buncic, Nikola
    Kabasi, Anton
    Cakaric, Tonci
    Bilusic, Ante
    INFORMACIJE MIDEM-JOURNAL OF MICROELECTRONICS ELECTRONIC COMPONENTS AND MATERIALS, 2019, 49 (01): : 3 - 9
  • [10] Robust Hydrophone with Hydrothermal PZT Thick-Film Vibrator and Titanium Front Layer for Use in High-Power Ultrasound Fields
    Okada, Nagaya
    Takeuchi, Shinichi
    2015 JOINT IEEE INTERNATIONAL SYMPOSIUM ON THE APPLICATIONS OF FERROELECTRIC, INTERNATIONAL SYMPOSIUM ON INTEGRATED FUNCTIONALITIES AND PIEZOELECTRIC FORCE MICROSCOPY WORKSHOP (ISAF/ISIF/PFM), 2015, : 147 - 150