Reconstruction of mammography x-ray spectrum by using Rayleigh and Compton scattering corrections

被引:0
作者
Kawaguchi, Souichiro [1 ]
Yamaguchi, Yoshiki [1 ]
Arimura, Hidetaka [2 ]
Morishita, Junji [2 ]
Ohki, Masafumi [2 ]
Uno, Yoshinori [1 ]
Ideguchi, Tadamitsu [3 ]
Higashida, Yoshiharu [2 ]
Toyofuku, Fukai [2 ]
机构
[1] Kyushu Univ, Dept Hlth Sci, Grad Sch Med Sci, Higashi Ku, Fukuoka, Japan
[2] Kyushu Univ, Fac Med Sci, Dept Hlth Sci, Fukuoka, Japan
[3] National Hosp Org Kumamoto Med Ctr, Kumamoto, Japan
来源
WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING, VOL 25, PT 2 - DIAGNOSTIC IMAGING | 2009年 / 25卷
关键词
90-degree scattered x-ray spectrum; Rayleigh scattering; Compton scattering; Monte Carlo simulation; DIAGNOSTIC-RADIOLOGY;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The analysis of the x-ray spectrum is important for quality assurance (QA) and quality control (QC) of a radiographic system such as mammography. In the case of mammography, the direct measurement of the primary x-ray spectra under clinical conditions is very difficult and time-consuming mainly because it is almost impossible to increase the longitudinal distance between the focal spot and x-ray detector in order to make the photon counting measurement possible. An alternative way of measuring the primary spectra is to correct the 90 degree scattered x-ray spectra which can be measured without photon pile-up since the intensity of the scattered x-rays is significantly lowered. The scattered x-ray spectrum is composed of two components, Compton scattered photons and Rayleigh scattered photons. We have developed a new method of reconstructing the primary x-ray spectrum from the scattered x-ray spectrum taking into account both Rayleigh and Compton scattered photons. The 90 degree scattered x-ray spectrum from a 28 kV mammography x-ray unit was measured at a tube voltage by using a CdTe semiconductor detector. The reconstructed spectrum agreed fairly well with a directly measured primary x-ray spectrum. The Rayleigh and Compton scattering correction method could be suitable for measuring the mammography x-ray spectra under clinical conditions and useful for QA and QC of the mammography x-ray units.
引用
收藏
页码:231 / 233
页数:3
相关论文
共 7 条
[1]   Monte Carlo simulation of a computed tomography x-ray tube [J].
Bazalova, Magdalena ;
Verhaegen, Frank .
PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (19) :5945-5955
[2]   THE VALIDITY OF MONTE-CARLO SIMULATION IN STUDIES OF SCATTERED RADIATION IN DIAGNOSTIC-RADIOLOGY [J].
CHAN, HP ;
DOI, K .
PHYSICS IN MEDICINE AND BIOLOGY, 1983, 28 (02) :109-129
[3]  
Hubbell J. H., 1975, Journal of Physical and Chemical Reference Data, V4, P471, DOI 10.1063/1.555523
[4]   COHERENT SCATTER IN DIAGNOSTIC-RADIOLOGY [J].
JOHNS, PC ;
YAFFE, MJ .
MEDICAL PHYSICS, 1983, 10 (01) :40-50
[5]  
Kimme-Smith C, 1999, RADIOLOGY
[6]  
Kurucu Y., 1998, T J PHYS, V22, P783
[7]   Compton-scattering measurement of diagnostic x-ray spectrum using high-resolution Schottky CdTe detector [J].
Maeda, K ;
Matsumoto, M ;
Taniguchi, A .
MEDICAL PHYSICS, 2005, 32 (06) :1542-1547