High-speed imaging used to detect vocal fold paresis: A case report

被引:18
作者
Mortensen, Melissa [1 ]
Woo, Peak [1 ]
机构
[1] Mt Sinai Med Ctr, Dept Otolaryngol Head & Neck Surg, New York, NY 10029 USA
关键词
high-speed imaging; vocal fold paresis;
D O I
10.1177/000348940811700910
中图分类号
R76 [耳鼻咽喉科学];
学科分类号
100213 ;
摘要
High-speed imaging has been used to study vocal fold vibration and has been shown to provide additional information in aid of our understanding of pathologic vocal fold vibration. This is the first case report of vocal fold paresis diagnosed by high-speed imaging. An 18-year-old girl presented with intermittent voice loss that had been present for 4 years. The patient had been seen by other otolaryngologists and had been given proton pump inhibitors without any improvement in her voice. Her voice was diplophonic. The patient was examined by rigid stroboscopy and was found to have a predominantly open phase pattern but a normal vibratory pattern. High-speed photography showed a distinct vibratory frequency for each vocal fold, suggestive of a paresis pattern. Laryngeal electromyography confirmed the diagnosis of vocal fold paresis. A computed tomographic scan of the larynx and chest showed a thymoma. After thymectomy, the patient recovered full voice function. High-speed imaging is useful for the clinical evaluation of pathologic vocal fold vibration and can detect subtle features of paralysis that may not be detected on fiberoptic endoscopy and rigid stroboscopy. The additional information from high-speed imaging helped to make the diagnosis of vocal fold paresis in this patient.
引用
收藏
页码:684 / 687
页数:4
相关论文
共 12 条
  • [1] CHILDERS DG, 1977, CRC CR REV BIOM ENG, V2, P375
  • [2] Vocal fold vibration irregularities caused by different types of laryngeal asymmetry
    Eysholdt, U
    Rosanowski, F
    Hoppe, U
    [J]. EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY, 2003, 260 (08) : 412 - 417
  • [3] Farnsworth D.W., 1940, Bell Laboratories Record, V18, P203
  • [4] Hertegard Stellan, 2005, Curr Opin Otolaryngol Head Neck Surg, V13, P152, DOI 10.1097/01.moo.0000163451.98079.ba
  • [5] IMAIZUMI S, 1991, ANN B RES I LOGOP PH, V25, P55
  • [6] KIRITANI S, 1991, ANN B RILP, V25, P55
  • [7] Vocal fold vibrations:: High-speed imaging, kymography, and acoustic analysis:: A preliminary report
    Larsson, H
    Hertegård, S
    Lindestad, PÅ
    Hammarberg, B
    [J]. LARYNGOSCOPE, 2000, 110 (12) : 2117 - 2122
  • [8] Videokymography: High-speed line scanning of vocal fold vibration
    Svec, JG
    Schutte, HK
    [J]. JOURNAL OF VOICE, 1996, 10 (02) : 201 - 205
  • [9] Tigges M, 1997, ACUSTICA, V83, P707
  • [10] Titze I. R., 1994, PRINCIPLES VOICE PRO