Vibration-based condition monitoring for the pump using fuzzy technique

被引:0
作者
Cui Houxi [1 ]
Zhang Laibin [1 ]
Wang Zhaohui [1 ]
Duan Lixiang [1 ]
Fan Xiaojing [1 ]
机构
[1] China Univ Petr, Res Ctr Oil & Gas Safety Engn Technol, Beijing 102249, Peoples R China
来源
ENGINEERING STRUCTURAL INTEGRITY: RESEARCH, DEVELOPMENT AND APPLICATION, VOLS 1 AND 2 | 2007年
关键词
D O I
暂无
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Fuzzy technique has been widely used in the condition monitoring of the equipment. However, some limitations exist in the application of the technique due to the insufficient utilization of the information and the subjective expert judgment. The condition monitoring using fuzzy technique based on the vibration analysis is presented in this paper in order to solve these issues. Furthermore, A load modification theory proposed in this paper is centered on the signal preprocess. In addition, the degradation theory is utilized aiming at increasing the accuracy and reducing the error caused by subjective human judgment. The condition is evaluated on the basis of the degradation degree of the characteristic parameters and the fuzzy relation matrix. The application shows that this technique provides an efficient approach for the condition monitoring.
引用
收藏
页码:1224 / 1226
页数:3
相关论文
共 3 条
[1]   Cause and effect analysis by fuzzy relational equations and a genetic algorithm [J].
Rotshtein, Alexander P. ;
Posner, Morton ;
Rakytyanska, Hanna B. .
RELIABILITY ENGINEERING & SYSTEM SAFETY, 2006, 91 (09) :1095-1101
[2]   Vibration-based fault diagnosis of pump using fuzzy technique [J].
Wang, JP ;
Hu, HT .
MEASUREMENT, 2006, 39 (02) :176-185
[3]  
ZHANG LB, 2000, MECH EQUIPMENT FAULT