Multinational study of oestrogen and progesterone receptor immunocytochemistry on breast carcinoma fine needle aspirates

被引:19
作者
Marinsek, Z. P. [1 ]
Nolde, N. [1 ]
Kardum-Skelin, I. [2 ]
Nizzoli, R. [3 ]
Onal, B. [4 ]
Rezanko, T. [5 ]
Tani, E. [6 ]
Ostovic, K. T. [7 ]
Vielh, P. [8 ,9 ]
Schmitt, F. [10 ,11 ]
Kocjan, G. [12 ]
机构
[1] Inst Oncol, Dept Cytopathol, Ljubljana, Slovenia
[2] Clin Hosp Merkur, Zagreb, Croatia
[3] Parma Hosp, Div Med Oncol, Parma, Italy
[4] Ankara Diskapi Training & Res Hosp, Dept Pathol & Cytol, Ankara, Turkey
[5] Ataturk Training & Res Hosp, Dept Pathol, Izmir, Turkey
[6] Karolinska Univ Hosp, Dept Pathol & Cytol, Stockholm, Sweden
[7] Dubrava Univ Hosp, Ctr Clin Cytol & Cytometry, Zagreb, Croatia
[8] Inst Cancerol Gustave Roussy, Translat Res Lab, Dept Pathol, Villejuif, France
[9] Inst Cancerol Gustave Roussy, Biobank, Dept Pathol, Villejuif, France
[10] Porto Univ IPATIMUP, Inst Mol Pathol & Immunol, Oporto, Portugal
[11] Univ Porto, Fac Med, P-4100 Oporto, Portugal
[12] UCL, Dept Cellular Pathol, London, England
关键词
immunocytochemistry; fine needle aspiration cytology; hormonal receptors; oestrogen receptors; progesterone receptors; breast carcinoma; standardization; laboratory techniques; CYTOLOGIC SPECIMENS; MONOCLONAL-ANTIBODY; CANCER; SECTIONS; SAMPLES;
D O I
10.1111/cyt.12024
中图分类号
Q2 [细胞生物学];
学科分类号
071009 ; 090102 ;
摘要
Z. P. Marinsek, N. Nolde, I. Kardum-Skelin, R. Nizzoli, B. Onal, T. Rezanko, E. Tani, K. T. Ostovic, P. Vielh, F. Schmitt and G. Kocjan Multinational study of oestrogen and progesterone receptor immunocytochemistry on breast carcinoma fine needle aspirates Objectives: To collect data on the variability of immunocytochemical (ICC) procedures used to detect oestrogen/progesterone receptors (ER/PR) on cytological material; to test the reproducibility of results; and to identify the crucial points in the ICC procedures that affect the result. Methods: Ten laboratories from eight countries participated in a two-part study. In the first part, one of the participants (the coordinator) prepared and distributed cytospins from a fine needle aspirate of a primary breast carcinoma. Laboratories performed ICC staining for ER/PR according to their own methods on the test slides and in-house positive controls. Slides were returned to the coordinator together with information on the preparation of positive control slides and the ICC methodology used. In the second part, obligatory methods of fixation and antigen retrieval were specified. Evaluation of results included grading the number of positive cells, staining intensity, background staining, cytoplasmic staining, sample condition and cellularity. Participants evaluated their own results, which were subsequently evaluated by the coordinator. Results: There was great variability in the preparation of slides for in-house controls and ICC methodology. The outcome of ICC staining of in-house control slides was excellent in two laboratories, adequate in three, sub-optimal in four and inadequate in one. Only six obtained a positive reaction on the test slides and not all were of a high quality. Results of the second run were greatly improved in terms of cellularity of in-house positive control slides, and scores for the percentage of stained cells and staining intensity of control and test slides. Cytospins and monolayer (ThinPrep (R)) preparations were superior to direct smears; methods of fixation and antigen retrieval were the key points in the staining process. Conclusions: Our experience points to the need for guidelines for hormonal receptor determination and external quality control on cytological material, in order for cytological methods to be used in routine clinical practice with a suitable degree of confidence.
引用
收藏
页码:7 / 20
页数:14
相关论文
共 30 条
[1]  
[Anonymous], DIAGN CYTOPATHOL
[2]  
AZAVEDO E, 1986, ANTICANCER RES, V6, P263
[3]   Canadian Association of Pathologists-Association canadienne des pathologistes National Standards Committee/Immunohistochemistry [J].
Torlakovic, Emina Emilia ;
Riddell, Robert ;
Banerjee, Diponkar ;
El-Zimaity, Hala ;
Pilavdzic, Dragana ;
Dawe, Peter ;
Magliocco, Anthony ;
Barnes, Penny ;
Berendt, Richard ;
Cook, Donald ;
Gilks, Blake ;
Williams, Gaynor ;
Perez-Ordonez, Bayardo ;
Wehrli, Bret ;
Swanson, Paul E. ;
Otis, Christopher N. ;
Nielsen, Soren ;
Vyberg, Mogens ;
Butany, Jagdish .
AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 2010, 133 (03) :354-365
[4]   Estimation of hormone receptor status in fine-needle aspirates and paraffin-embedded sections from breast cancer using the novel rabbit monoclonal antibodies SP1 and SP2 [J].
Cano, G ;
Milanezi, F ;
Leitao, D ;
Ricardo, S ;
Brito, MJ ;
Schmitt, FC .
DIAGNOSTIC CYTOPATHOLOGY, 2003, 29 (04) :207-211
[5]  
Fitzgibbons PL, 2010, ARCH PATHOL LAB MED, V134, P930, DOI 10.1043/1543-2165-134.6.930
[6]   Optimal fixation conditions for immunocytochemical analysis of estrogen receptor in cytologic specimens of breast carcinoma [J].
Gong, Y ;
Symmans, WF ;
Krishnamurthy, S ;
Patel, S ;
Sneige, N .
CANCER CYTOPATHOLOGY, 2004, 102 (01) :34-40
[7]   American Society of Clinical Oncology/College of American Pathologists Guideline Recommendations for Immunohistochemical Testing of Estrogen and Progesterone Receptors in Breast Cancer [J].
Hammond, M. Elizabeth H. ;
Hayes, Daniel F. ;
Dowsett, Mitch ;
Allred, D. Craig ;
Hagerty, Karen L. ;
Badve, Sunil ;
Fitzgibbons, Patrick L. ;
Francis, Glenn ;
Goldstein, Neil S. ;
Hayes, Malcolm ;
Hicks, David G. ;
Lester, Susan ;
Love, Richard ;
Mangu, Pamela B. ;
McShane, Lisa ;
Miller, Keith ;
Osborne, C. Kent ;
Paik, Soonmyung ;
Perlmutter, Jane ;
Rhodes, Anthony ;
Sasano, Hironobu ;
Schwartz, Jared N. ;
Sweep, Fred C. G. ;
Taube, Sheila ;
Torlakovic, Emina Emilia ;
Valenstein, Paul ;
Viale, Giuseppe ;
Visscher, Daniel ;
Wheeler, Thomas ;
Williams, R. Bruce ;
Wittliff, James L. ;
Wolff, Antonio C. .
JOURNAL OF CLINICAL ONCOLOGY, 2010, 28 (16) :2784-2795
[8]  
Hudock JA, 1996, DIAGN CYTOPATHOL, V15, P78, DOI 10.1002/(SICI)1097-0339(199607)15:1<78::AID-DC17>3.0.CO
[9]  
2-9
[10]   External quality control for immunocytochemistry on cytology samples: a review of UK NEQAS ICC (cytology module) results [J].
Kirbis, I. S. ;
Maxwell, P. ;
Flezar, M. S. ;
Miller, K. ;
Ibrahim, M. .
CYTOPATHOLOGY, 2011, 22 (04) :230-237