INVESTIGATION OF EBT3 RADIOCHROMIC FILM RESPONSE IN A HIGH-DOSE RANGE OF 6 MV PHOTON AND 6 MEV ELECTRON BEAMS USING A THREE-COLOR FLATBED SCANNER

被引:5
作者
Duruer, Kerem [1 ]
Etiz, Durmus [1 ]
Yucel, Haluk [2 ]
机构
[1] Eskisehir Osmangazi Univ, Fac Med, Dept Radiat Oncol, TR-26010 Odunpazari, Eskisehir, Turkey
[2] Ankara Univ, Inst Nucl Sci, TR-06500 Ankara, Turkey
来源
EAST EUROPEAN JOURNAL OF PHYSICS | 2020年 / 03期
关键词
Radiochromic Film; Uncertainty; High Dose Range; Radiotherapy; Flatbed Scanner; DOSIMETRY;
D O I
10.26565/2312-4334-2020-3-02
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
Radiochromic film dosimetry has been commonly used for determination of dose measurement in radiotherapy for many years because of their high spatial resolution, low energy dependence and its approximate tissue equivalent. Additionally, it has other practical advantages, e.g.it is suitable for therapy range beam qualities, a water resistance material, a relatively insensitive to visible light, and does not need to make bathing process to obtain dose information. They are also independent to dose rate. Hence, they are very useful and practical for clinical applications such as brachytherapy, electron therapy, skin dose measurements and stereotactic radiotherapy. Among them, the dynamic dose range of EBT3 radiochromic films are generally recommended for the dose range of 0.1 to 20 Gy. However, in this study, it is aimed to observe the behavior of EBT3 films in high dose range of up to 90 Gy under the irradiations. For this aim, the net optical densities were obtained with increasing dose values under photon and electron beams by employing three color scanning channels (red-green-blue). Thus, for making calibration curves, it was decided which color channel for EBT3 radiochromic film would be the most suitable one in different dose ranges. In experimental setup, the reference circumstances were first established and dose calibration procedure was carried out in RW3 phantom. Then the irradiated films were cut carefully into 2X2.5 cm(2) pieces, and they were grouped into 2 as irradiation and control groups. The control group was waited for background, i.e. they are not irradiated. Before the irradiation, two groups of films have been scanned in flatbed scanner for three channels. After that, the irradiation group films were placed to align the exact place of effective point of ionization chamber under the reference condition. Later, they were irradiated one by one to up to 90 Gy with using 6 MV and 6 MeV beam qualities, respectively. Subsequently, both of film groups were again scanned in flatbed scanner for three -color channels. Optical densities and their standard deviations corresponding to the chosen dose values were obtained from the scanned films. Thus, calibration curves were plotted for all three colors channel according to two different beam conditions. The results obtained for 6 MV beam quality showed that if red color channel is selected for 0.9 Gy-7.3 Gy dose range, and green color channel is selected for 7.3 Gy-42.8 Gy dose range, and blue color channel is selected for 42.8 Gy-90.0 Gy dose range, the percentage uncertainty values in the obtained results are minimal. For the 6 MeV beam quality, if red color channel is selected for 0.9 Gy-7.7 Gy dose range, and green color channel is selected for 7.7 Gy-45.3 Gy dose range, and blue color channel is selected for 45.3 Gy-90.0 Gy dose range, the percentage uncertainty values in the obtained results are minimal. In conclusion, the percentage uncertainty values for the obtained results were evaluated for 6 MV photon and 6 MeV electron energies by using different scanning channels of EBT3 radiochromic film. It has been found that measurements having low percentage uncertainty values can be achieved by changing the scanning channel by deciding proper combinations with increasing doses for both energies (6MV photon and 6 MeV electron). The study also shows that EBT3 radiochromic films can be used at lower percentage uncertainty values at doses higher than the recommended dose range values.
引用
收藏
页码:11 / 18
页数:8
相关论文
共 21 条
[1]   Improving the energy response of external beam therapy (EBT) GafChromic™ dosimetry films at low energies (≤100 keV) [J].
Bekerat, H. ;
Devic, S. ;
DeBlois, F. ;
Singh, K. ;
Sarfehnia, A. ;
Seuntjens, J. ;
Shih, Shelley ;
Yu, Xiang ;
Lewis, D. .
MEDICAL PHYSICS, 2014, 41 (02)
[2]   Stereotactic body radiation therapy: The report of AAPM Task Group 101 [J].
Benedict, Stanley H. ;
Yenice, Kamil M. ;
Followill, David ;
Galvin, James M. ;
Hinson, William ;
Kavanagh, Brian ;
Keall, Paul ;
Lovelock, Michael ;
Meeks, Sanford ;
Papiez, Lech ;
Purdie, Thomas ;
Sadagopan, Ramaswamy ;
Schell, Michael C. ;
Salter, Bill ;
Schlesinger, David J. ;
Shiu, Almon S. ;
Solberg, Timothy ;
Song, Danny Y. ;
Stieber, Volker ;
Timmerman, Robert ;
Tome, Wolfgang A. ;
Verellen, Dirk ;
Wang, Lu ;
Yin, Fang-Fang .
MEDICAL PHYSICS, 2010, 37 (08) :4078-4101
[3]   Dosimetric characterization and use of GAFCHROMIC EBT3 film for IMRT dose verification [J].
Borca, Valeria Casanova ;
Pasquino, Massimo ;
Russo, Giuliana ;
Grosso, Pierangelo ;
Cante, Domenico ;
Sciacero, Piera ;
Girelli, Giuseppe ;
La Porta, Maria Rosa ;
Tofani, Santi .
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2013, 14 (02) :158-171
[4]  
Butson M., 2017, RADIOCHROMIC FILM RO, P7
[5]  
Butson M., 2017, RADIOCHROMIC FILM RO, P34
[6]  
Das I.J., 2017, RADIOCHROMIC FILM RO, pxiii
[7]   Reference radiochromic film dosimetry: Review of technical aspects [J].
Devic, Slobodan ;
Tomic, Nada ;
Lewis, David .
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2016, 32 (04) :541-556
[8]   Radiochromic film dosimetry: Past, present, and future [J].
Devic, Slobodan .
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2011, 27 (03) :122-134
[9]  
Hohlfeld K., 2006, IAEA Technical Report Series, V398
[10]  
Kang Sang-Won, 2017, [PROGRESS in MEDICAL PHYSICS, 의학물리], V28, P16, DOI 10.14316/pmp.2017.28.1.16