DEVELOPMENT OF WEARABLE GAIT EVALUATION SYSTEM A Preliminary Test of Measurement of Joint Angles and Stride Length

被引:0
作者
Watanabe, Takashi [1 ]
Saito, Hiroki [1 ]
Koike, Eri [1 ]
Nitta, Kazuki [1 ]
机构
[1] Tohoku Univ, Dept Biomed Enginerring, Sendai, Miyagi 980, Japan
来源
BIOSIGNALS 2011 | 2011年
关键词
Gait; Gyroscope; Accelerometer; Joint angle; Kalman filter; Stride length; ACCELEROMETERS;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The purpose of this study is to develop wearable sensor system for gait evaluation using gyroscopes and accelerometers for application to rehabilitation, healthcare and so on. In this paper, simultaneous measurement of joint angles of the lower limbs and stride length was tested with a prototype of wearable sensor system. The system measured the joint angles using the Kalman filter. Signals from the sensor attached on the foot were used in the stride length estimation detecting foot movement automatically. Joint angles of the lower limbs and the stride length were measured with reasonable accuracy compared to those values measured with optical motion measurement system with healthy subjects. Joint angle patterns measured in 10m walking with a healthy subject were similar to common patterns. High correlation between joint angles at some characteristic points and walking speed were also found adequately from measured data. The system was suggested to be able to detect characteristics of gait.
引用
收藏
页码:245 / 250
页数:6
相关论文
共 15 条
  • [1] Alvarez JC, 2007, P ANN INT IEEE EMBS, P5720
  • [2] Gait analysis using a shoe-integrated wireless sensor system
    Bamberg, Stacy J. Morris
    Benbasat, Ari Y.
    Scarborough, Donna Moxley
    Krebs, David E.
    Paradiso, Joseph A.
    [J]. IEEE TRANSACTIONS ON INFORMATION TECHNOLOGY IN BIOMEDICINE, 2008, 12 (04): : 413 - 423
  • [3] Cikajlo I., 2008, Journal of Medical Engineering & Technology, V32, P133, DOI 10.1080/03091900601029627
  • [4] A new approach to accurate measurement of uniaxial joint angles based on a combination of accelerometers and gyroscopes
    Dejnabadi, H
    Jolles, BM
    Aminian, K
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2005, 52 (08) : 1478 - 1484
  • [5] Predicting lower limb joint kinematics using wearable motion sensors
    Findlow, A.
    Goulermas, J. Y.
    Nester, C.
    Howard, D.
    Kenney, L. P. J.
    [J]. GAIT & POSTURE, 2008, 28 (01) : 120 - 126
  • [6] Modified pendulum model for mean step length estimation
    Gonzalez, Rafael C.
    Alvarez, Diego
    Lopez, Antonio M.
    Alvarez, Juan C.
    [J]. 2007 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-16, 2007, : 1371 - 1374
  • [7] Gait event detection using linear accelerometers or angular velocity transducers in able-bodied and spinal-cord injured individuals
    Jasiewicz, Jan M.
    Allum, John H. J.
    Middleton, James W.
    Barriskill, Andrew
    Condie, Peter
    Purcell, Brendan
    Li, Raymond Che Tin
    [J]. GAIT & POSTURE, 2006, 24 (04) : 502 - 509
  • [8] The reliability of using accelerometer and gyroscope for gait event identification on persons with dropped foot
    Lau, Hongyin
    Tong, Kaiyu
    [J]. GAIT & POSTURE, 2008, 27 (02) : 248 - 257
  • [9] Lee SW, 2005, P ANN INT IEEE EMBS, P6836
  • [10] Minegishi Y., 2010, J SOC BIOMECHANISMS, V34, P63