A novel H2O2 amperometric biosensor based on gold nanoparticles/self-doped polyaniline nanofibers

被引:74
作者
Chen, Xiaojun [1 ]
Chen, Zixuan [1 ]
Zhu, Jinwei [1 ]
Xu, Chenbin [1 ]
Yan, Wei [2 ]
Yao, Cheng [1 ]
机构
[1] Nanjing Univ Technol, Coll Sci, Nanjing 210009, Peoples R China
[2] Shanghai Univ, Nano Sci & Technol Res Ctr, Shanghai 200444, Peoples R China
基金
中国国家自然科学基金;
关键词
Gold nanoparticles/self-doped polyaniline nanofibers; Horseradish peroxidase; H2O2; Biosensor; HYDROGEN-PEROXIDE BIOSENSOR; DIRECT ELECTRON-TRANSFER; GLASSY-CARBON ELECTRODE; HORSERADISH-PEROXIDASE; GLUCOSE BIOSENSOR; ELECTROCHEMICAL SYNTHESIS; CONDUCTING POLYMERS; SYNTHESIZED SILICA; NANOTUBE ARRAYS; COMPOSITE FILM;
D O I
10.1016/j.bioelechem.2011.05.004
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
A new kind of gold nanoparticles/self-doped polyaniline nanofibers (Au/SPAN) with grooves has been prepared for the immobilization of horseradish peroxidase (HRP) on the surface of glassy carbon electrode (GCE). The ratio of gold in the composite nanofibers was up to 64%, which could promote the conductivity and biocompatibility of SPAN and increase the immobilized amount of HRP molecules greatly. The electrode exhibits enhanced electrocatalytic activity in the reduction of H2O2 in the presence of the mediator hydroquinone (HQ). The effects of concentration of HQ solution pH and the working potential on the current response of the modified electrode toward H2O2 were optimized to obtain the maximal sensitivity. The proposed biosensor exhibited a good linear response in the range from 10 to 2000 mu M with a detection limit of 1.6 mu M (S/N = 3) under the optimum conditions. The response showed Michaelis-Menten behavior at larger H2O2 concentrations, and the apparent Michaelis-Menten constant K-m was estimated to be 2.21 mM. The detection of H2O2 concentration in real sample showed acceptable accuracy with the traditional potassium permanganate titration. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:87 / 94
页数:8
相关论文
共 48 条
[1]   A Single ZnO Nanofiber-Based Highly Sensitive Amperometric Glucose Biosensor [J].
Ahmad, Mashkoor ;
Pan, Caofeng ;
Luo, Zhixiang ;
Zhu, Jing .
JOURNAL OF PHYSICAL CHEMISTRY C, 2010, 114 (20) :9308-9313
[2]  
ARUNAS R, 1999, ANAL CHEM, V71, P3581
[3]   Semiconductor nanocrystals as fluorescent biological labels [J].
Bruchez, M ;
Moronne, M ;
Gin, P ;
Weiss, S ;
Alivisatos, AP .
SCIENCE, 1998, 281 (5385) :2013-2016
[4]   Amperometric hydrogen peroxide biosensor based on the immobilization of horseradish peroxidase (HRP) on the layer-by-layer assembly films of gold colloidal nanoparticles and toluidine blue [J].
Chen, SH ;
Yuan, R ;
Chai, YQ ;
Xu, L ;
Wang, N ;
Li, XN ;
Zhang, LY .
ELECTROANALYSIS, 2006, 18 (05) :471-477
[5]   Effect of silver nanoparticles on the electron transfer reactivity and the catalytic activity of myoglobin [J].
Gan, X ;
Liu, T ;
Zhong, J ;
Liu, XJ ;
Li, GX .
CHEMBIOCHEM, 2004, 5 (12) :1686-1691
[6]   Entrapment of enzymes and carbon nanotubes in biologically synthesized silica:: Glucose oxidase-catalyzed direct electron transfer [J].
Ivnitski, Dmitri ;
Artyushkova, Kateryna ;
Rincon, Rosalba A. ;
Atanassov, Plamen ;
Luckarift, Heather R. ;
Johnson, Glenn R. .
SMALL, 2008, 4 (03) :357-364
[7]   A novel hydrogen peroxide biosensor based on the immobilization of horseradish peroxidase onto Au-modified titanium dioxide nanotube arrays [J].
Kafi, A. K. M. ;
Wu, Guosheng ;
Chen, Aicheng .
BIOSENSORS & BIOELECTRONICS, 2008, 24 (04) :566-571
[8]   ROTATING-RING-DISK ENZYME ELECTRODE FOR BIOCATALYSIS KINETIC-STUDIES AND CHARACTERIZATION OF THE IMMOBILIZED ENZYME LAYER [J].
KAMIN, RA ;
WILSON, GS .
ANALYTICAL CHEMISTRY, 1980, 52 (08) :1198-1205
[9]   Glucose Oxidase-graphene-chitosan modified electrode for direct electrochemistry and glucose sensing [J].
Kang, Xinhuang ;
Wang, Jun ;
Wu, Hong ;
Aksay, Ilhan A. ;
Liu, Jun ;
Lin, Yuehe .
BIOSENSORS & BIOELECTRONICS, 2009, 25 (04) :901-905
[10]   Microtubule sensors and sensor array based on polyaniline synthesized in the presence of poly(styrene sulfonate) [J].
Kanungo, M ;
Kumar, A ;
Contractor, AQ .
ANALYTICAL CHEMISTRY, 2003, 75 (21) :5673-5679