First-in-man experience with a new embolic deflection device in transcatheter aortic valve interventions

被引:67
作者
Onsea, Kevin [1 ]
Agostoni, Pierfrancesco [1 ]
Samim, Mariam [1 ]
Voskuil, Michiel [1 ]
Kluin, Jolanda [2 ]
Budde, Ricardo [3 ]
Hendrikse, Jeroen [3 ]
Ramjankhan, Faiz [2 ]
van Klarenbosch, Jan [4 ]
Doesburg, Pieter [4 ]
Sieswerda, Gertjan [1 ]
Stella, Pieter [1 ]
机构
[1] Univ Med Ctr Utrecht, Dept Cardiol, NL-3584 CX Utrecht, Netherlands
[2] Univ Med Ctr Utrecht, Dept Cardiothorac Surg, Utrecht, Netherlands
[3] Univ Med Ctr Utrecht, Dept Radiol, Utrecht, Netherlands
[4] Univ Med Ctr Utrecht, Dept Anaesthesiol, Utrecht, Netherlands
关键词
stroke; cerebral protection device; TAVI; CEREBRAL EMBOLISM; IMPLANTATION; SILENT; REPLACEMENT; RETROGRADE; STENOSIS; RISK;
D O I
10.4244/EIJV8I1A9
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims: To report our first-in-man experience with a new cerebral embolic deflection device (SMT Embolic Deflection Device) during transcatheter aortic valve implantation (TAVI). A significant number of strokes and brain infarcts are caused by embolisation of atherosclerotic material, clots and other debris during various phases of invasive cardiac procedures, especially TAVI. The application of a temporary filter in the aortic arch averting dislodged emboli from entering the cerebral circulation might prevent this. Methods and results: In 15 patients (mean age 79 years) with severe aortic stenosis undergoing percutaneous transfemoral or transapical aortic valve implantation, the SMT Embolic Deflection Device was advanced utilising the contralateral femoral artery access using a 9 Fr delivery sheath. Once deployed in the aortic arch, a porous membrane shields the supraaortic-cerebral trunks by deflecting emboli away from the cerebral circulation. Embolic material is not contained or removed by the device. A 6 Fr pigtail catheter can be used through the same sheath throughout the whole procedure. Brain diffusion weighted (DW)-MRI was obtained in 10 patients before and at 4 days after (+/- 2 days) the procedure and retrospectively compared to 20 patients previously undergoing TAVI without a protection device. Successful placement of the embolic protection device was achieved in all patients. Additional procedural time due to the use of the device was 7 min (+/- 2 min). There were no procedural complications. No patient developed new neurological symptoms or clinical findings of stroke except one patient who suffered from a transient ischaemic attack (TIA) two days after the procedure. DW-MRI showed 3.2 new cerebral lesions per patient, compared to 7.2 new lesions per patient in the group without SMT filter. Conclusions: In this first-in-man experience, the feasibility of a new embolic deflection device is demonstrated. Larger randomised, prospective studies are required to confirm these findings and prove safety and efficacy by reducing the incidence of cerebral embolism and stroke after TAVI.
引用
收藏
页码:51 / 56
页数:6
相关论文
共 17 条
[1]   Incidence and Predictors of Stroke Associated With Percutaneous Coronary Intervention [J].
Aggarwal, Atul ;
Dai, David ;
Rumsfeld, John S. ;
Klein, Lloyd W. ;
Roe, Matthew T. .
AMERICAN JOURNAL OF CARDIOLOGY, 2009, 104 (03) :349-353
[2]   Tools & Techniques: Percutaneous intervention of saphenous vein graft lesions [J].
Agostoni, Pierfrancesco ;
Voskuil, Michiel ;
Onsea, Kevin ;
Vermeersch, Paul ;
Stella, Pieter R. .
EUROINTERVENTION, 2011, 7 (07) :878-879
[3]   Embolic Cerebral Insults After Transapical Aortic Valve Implantation Detected by Magnetic Resonance Imaging [J].
Arnold, Martin ;
Schulz-Heise, Susanne ;
Achenbach, Stephan ;
Ott, Sabine ;
Doerfler, Arnd ;
Ropers, Dieter ;
Feyrer, Richard ;
Einhaus, Friedrich ;
Loders, Sabrina ;
Mahmoud, Faidi ;
Roerick, Olaf ;
Daniel, Werner G. ;
Weyand, Michael ;
Ensminger, Stephan M. ;
Ludwig, Josef .
JACC-CARDIOVASCULAR INTERVENTIONS, 2010, 3 (11) :1126-1132
[4]   Magnetic resonance imaging evaluation of cerebral embolization during percutaneous aortic valve implantation: comparison of transfemoral and trans-apical approaches using Edwards Sapiens valve [J].
Astarci, Parla ;
Glineur, David ;
Kefer, Joelle ;
D'Hoore, William ;
Renkin, Jean ;
Vanoverschelde, Jean-Louis ;
El Khoury, Gebrine ;
Grandin, Cecile .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2011, 40 (02) :475-479
[5]   Risk and Fate of Cerebral Embolism After Transfemoral Aortic Valve Implantation A Prospective Pilot Study With Diffusion-Weighted Magnetic Resonance Imaging [J].
Ghanem, Alexander ;
Mueller, Andreas ;
Naehle, Claas P. ;
Kocurek, Justine ;
Werner, Nikos ;
Hammerstingl, Christoph ;
Schild, Hans H. ;
Schwab, Joerg O. ;
Mellert, Fritz ;
Fimmers, Rolf ;
Nickenig, Georg ;
Thomas, Daniel .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2010, 55 (14) :1427-1432
[6]   Percutaneous aortic valve replacement for severe aortic stenosis in high-rick patients using the second- and current third-generation self-expanding CoreValve prosthesis - Device success and 30-day clinical outcome [J].
Grube, Eberhard ;
Schuler, Gerhard ;
Buellesfeld, Lutz ;
Gerckens, Ulrich ;
Linke, Axel ;
Wenaweser, Peter ;
Sauren, Barthel ;
Mohr, Friedrich-Wilhelm ;
Walther, Thomas ;
Zickmann, Bernfried ;
Iversen, Stein ;
Felderhoff, Thomas ;
Cartier, Raymond ;
Bonan, Raoul .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2007, 50 (01) :69-76
[7]   Carotid angioplasty and stenting under protection: advantages and drawbacks [J].
Henry, Michel ;
Polyorou, Antonio ;
Henry, Isabelle ;
Polyclorou, Amanda D. ;
Hugel, Michele .
EXPERT REVIEW OF MEDICAL DEVICES, 2008, 5 (05) :591-603
[8]  
Kahlert P, 2010, TRANSC CARD THER WAS
[9]   Silent and Apparent Cerebral Ischemia After Percutaneous Transfemoral Aortic Valve Implantation A Diffusion-Weighted Magnetic Resonance Imaging Study [J].
Kahlert, Philipp ;
Knipp, Stephan C. ;
Schlamann, Marc ;
Thielmann, Matthias ;
Al-Rashid, Fadi ;
Weber, Marcel ;
Johansson, Uw ;
Wendt, Daniel ;
Jakob, Heinz G. ;
Forsting, Michael ;
Sack, Stefan ;
Erbel, Raimund ;
Eggebrecht, Holger .
CIRCULATION, 2010, 121 (07) :870-878
[10]   Scraping of aortic debris by coronary guiding catheters - A prospective evaluation of 1,000 cases [J].
Keeley, EC ;
Grines, CL .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1998, 32 (07) :1861-1865