Detection of Hg2+ using molecular beacon-based fluorescent sensor with high sensitivity and tunable dynamic range

被引:23
作者
Teh, Hui Boon [1 ]
Wu, Huanan [2 ]
Zuo, Xinbing [1 ]
Li, Sam Fong Yau [1 ,2 ,3 ]
机构
[1] Natl Univ Singapore, Dept Chem, Singapore 117543, Singapore
[2] NUS Environm Res Inst, Singapore 117411, Singapore
[3] Peking Univ, Shenzhen Grad Sch, Sch Environm & Energy, Shenzhen Engn Lab Ecoefficient Polysilicate Mat, Shenzhen 518055, Peoples R China
基金
新加坡国家研究基金会;
关键词
Molecular beacon; T-Hg2+-T coordination; Mercury; Fluorescence; Biosensor; PLASMA-MASS SPECTROMETRY; COLORIMETRIC DETECTION; SELECTIVE DETECTION; AQUEOUS-SOLUTIONS; STRANDED-DNA; PB2+ IONS; TURN-ON; MERCURY; PROBE; DNAZYME;
D O I
10.1016/j.snb.2014.01.089
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A molecular beacon (MB) sensor was developed for highly sensitive and specific detection of Hg2+ ions with a tunable dynamic range. This method was based on the "turn-on" reaction of a hairpin DNA probe upon binding with mismatched target and Hg2+ ions through the formation of T-Hg2+-T coordination. The conformational change of the MB caused a significant increase in fluorescence intensity, which could be used for Hg2+ sensing. The dynamic range of the sensor could be tuned by rationally controlling the number of T-T mismatches in between the MB loop and mismatched target DNA in the cases where detection of Hg2+ at different concentration ranges is required. With three T-T mismatches in the sequences, the sensor showed higher sensitivity with detection limit of 1.9 nM but narrower dynamic range. Further adding the number of T-T mismatches to seven, the sensor showed wider dynamic range but compromised sensitivity with detection limit of 44.2 nM. By mixing different mismatched targets in the assay, we found that both good sensitivity and wide dynamic range can be achieved. Adding small portion of T3 and T5 to T7 in the assay, the detection limit was significantly lower to 9.5 nM without sacrificing dynamic range. Based on the results, the mechanism of Hg2+ detection based on interaction between MB and mismatched targets was discussed. This sensor showed excellent selectivity toward Hg2+ ions in the presence of other metal ions. The proposed strategy was also able to detect Hg2+ in real water samples. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:623 / 629
页数:7
相关论文
共 50 条
[21]   A selective fluorescent sensor for Hg2+ based on covalently immobilized naphthalimide derivative [J].
Wu, Xue-Fen ;
Ma, Qiu-Juan ;
Wei, Xiao-Jie ;
Hou, Yi-Min ;
Zhu, Xin .
SENSORS AND ACTUATORS B-CHEMICAL, 2013, 183 :565-573
[22]   A fluorescent probe for the dual-channel detection of Hg2+/Ag+ and its Hg2+-based complex for detection of mercapto biomolecules with a tunable measuring range [J].
Fan, Juan ;
Chen, Cheng ;
Lin, Qian ;
Fu, Nanyan .
SENSORS AND ACTUATORS B-CHEMICAL, 2012, 173 :874-881
[23]   A highly sensitivity fluorescent probe based on rhodamine for naked-eye detection of Hg2+ in aqueous solution [J].
Meng, Xianjiao ;
Li, Zhichun ;
Ma, Wenbing .
INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2023, 103 (17) :5558-5568
[24]   Responsive nanogel-based dual fluorescent sensors for temperature and Hg2+ ions with enhanced detection sensitivity [J].
Li, Changhua ;
Liu, Shiyong .
JOURNAL OF MATERIALS CHEMISTRY, 2010, 20 (47) :10716-10723
[25]   Detection and discrimination of Zn2+ and Hg2+ using a single molecular fluorescent probe [J].
Gharami, Saswati ;
Aich, Krishnendu ;
Patra, Lakshman ;
Mondal, Tapan K. .
NEW JOURNAL OF CHEMISTRY, 2018, 42 (11) :8646-8652
[26]   Ratio fluorescence sensor based on CD/Cu-MOFs for detection of Hg2+ [J].
Hou, J. I. N. G. Z. H. O. U. ;
Zhang, Y. A. ;
Ming, F. A. N. G. L. I. N. ;
Hong, Y. I. Y. I. H. U. I. ;
Liu, H. U. A. N. ;
He, Q. I. A. N. G. ;
Hou, C. H. A. N. G. J. U. N. ;
Huo, D. A. N. Q. U. N. .
APPLIED OPTICS, 2023, 62 (06) :A127-A136
[27]   Detection of Hg2+ ions in aqueous medium using an indole-based fluorescent probe: Experimental and theoretical investigations [J].
Joshi, Sunita ;
Kumari, Santosh ;
Sarmah, Amrit ;
Pant, Debi D. ;
Sakhuja, Rajeev .
JOURNAL OF MOLECULAR LIQUIDS, 2017, 248 :668-677
[28]   Simple construction of a two-component fluorescent sensor for turn-on detection of Hg2+ in human serum [J].
Geng, Fenghua ;
Wang, Dandan ;
Shao, Congying ;
Li, Guixin ;
Xu, Maotian ;
Feng, Li .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2022, 414 (05) :2021-2028
[29]   Synthesis and sensing behavior of a new multichannel sensor based on thiazolyl ferrocene-rhodamine for Hg2+ detection [J].
Xu, Xiuling ;
Zheng, Bingbing ;
Deng, Hongxia ;
Zhang, Xiaoli ;
Shuai, Qi .
MICROCHEMICAL JOURNAL, 2020, 158
[30]   A 1,8-naphthalimide-based fluorescent sensor with high selectivity and sensitivity for Hg2+ in aqueous solution and living cells [J].
Liu, Daying ;
Zhu, Hualing ;
Shi, Jun ;
Deng, Xinxin ;
Zhang, Tingting ;
Zhao, Ye ;
Qi, Pengpeng ;
Yang, Guangming ;
He, Huarui .
ANALYTICAL METHODS, 2019, 11 (25) :3150-3154