Detection of Hg2+ using molecular beacon-based fluorescent sensor with high sensitivity and tunable dynamic range

被引:23
|
作者
Teh, Hui Boon [1 ]
Wu, Huanan [2 ]
Zuo, Xinbing [1 ]
Li, Sam Fong Yau [1 ,2 ,3 ]
机构
[1] Natl Univ Singapore, Dept Chem, Singapore 117543, Singapore
[2] NUS Environm Res Inst, Singapore 117411, Singapore
[3] Peking Univ, Shenzhen Grad Sch, Sch Environm & Energy, Shenzhen Engn Lab Ecoefficient Polysilicate Mat, Shenzhen 518055, Peoples R China
基金
新加坡国家研究基金会;
关键词
Molecular beacon; T-Hg2+-T coordination; Mercury; Fluorescence; Biosensor; PLASMA-MASS SPECTROMETRY; COLORIMETRIC DETECTION; SELECTIVE DETECTION; AQUEOUS-SOLUTIONS; STRANDED-DNA; PB2+ IONS; TURN-ON; MERCURY; PROBE; DNAZYME;
D O I
10.1016/j.snb.2014.01.089
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A molecular beacon (MB) sensor was developed for highly sensitive and specific detection of Hg2+ ions with a tunable dynamic range. This method was based on the "turn-on" reaction of a hairpin DNA probe upon binding with mismatched target and Hg2+ ions through the formation of T-Hg2+-T coordination. The conformational change of the MB caused a significant increase in fluorescence intensity, which could be used for Hg2+ sensing. The dynamic range of the sensor could be tuned by rationally controlling the number of T-T mismatches in between the MB loop and mismatched target DNA in the cases where detection of Hg2+ at different concentration ranges is required. With three T-T mismatches in the sequences, the sensor showed higher sensitivity with detection limit of 1.9 nM but narrower dynamic range. Further adding the number of T-T mismatches to seven, the sensor showed wider dynamic range but compromised sensitivity with detection limit of 44.2 nM. By mixing different mismatched targets in the assay, we found that both good sensitivity and wide dynamic range can be achieved. Adding small portion of T3 and T5 to T7 in the assay, the detection limit was significantly lower to 9.5 nM without sacrificing dynamic range. Based on the results, the mechanism of Hg2+ detection based on interaction between MB and mismatched targets was discussed. This sensor showed excellent selectivity toward Hg2+ ions in the presence of other metal ions. The proposed strategy was also able to detect Hg2+ in real water samples. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:623 / 629
页数:7
相关论文
共 50 条
  • [1] A label-free fluorescent sensor for the detection of Pb2+ and Hg2+
    Xu, Hanchu
    Zhan, Shenshan
    Zhang, Dongwei
    Xia, Bing
    Zhan, Xuejia
    Wang, Lumei
    Zhou, Pei
    ANALYTICAL METHODS, 2015, 7 (15) : 6260 - 6265
  • [2] Cleavable Molecular Beacon for Hg2+ Detection Based on Phosphorothioate RNA Modifications
    Huang, Po-Jung Jimmy
    Wang, Feng
    Liu, Juewen
    ANALYTICAL CHEMISTRY, 2015, 87 (13) : 6890 - 6895
  • [3] A New Fluorescent Chemodosimeter for Hg2+ with High Selectivity and Sensitivity in Water
    Yang, Dengchen
    Li, Meng
    Chen, Chuanfeng
    CHINESE JOURNAL OF CHEMISTRY, 2017, 35 (05) : 635 - 639
  • [4] A simple strategy to enhance the sensitivity of fluorescent sensor-based CdS quantum dots by using a surfactant for Hg2+ detection
    Sianglam, Pradthana
    Ngamdee, Kessarin
    Nalaoh, Phattananawee
    Promarak, Vinich
    Hunt, Andrew J.
    Ngeontae, Wittaya
    ANALYTICAL METHODS, 2021, 13 (36) : 4069 - 4078
  • [5] A highly selective pyrene based fluorescent sensor toward Hg2+ detection
    Yang, Yang
    Gou, Xiaojun
    Blecha, John
    Cao, Haishi
    TETRAHEDRON LETTERS, 2010, 51 (26) : 3422 - 3425
  • [6] Inhibitor effects on molecular beacon-based mercury assays for tuning of detection range
    Le, Van Sang
    Jeong, Ji-Eun
    Kim, Boram
    Lee, Jiae
    Kyhm, Kwangseuk
    Woo, Han Young
    SENSORS AND ACTUATORS B-CHEMICAL, 2017, 240 : 810 - 817
  • [7] An aqueous fluorescent probe for Hg2+ detection with high selectivity and sensitivity
    Fang, Qian
    Liu, Qian
    Song, Xiangzhi
    Kang, Jian
    LUMINESCENCE, 2015, 30 (08) : 1280 - 1284
  • [8] Cell Compatible Fluorescent Chemosensor for Hg2+ with High Sensitivity and Selectivity Based on the Rhodamine Fluorophore
    Jiang, Li
    Wang, Ling
    Zhang, Bo
    Yin, Gui
    Wang, Rui-Yong
    EUROPEAN JOURNAL OF INORGANIC CHEMISTRY, 2010, (28) : 4438 - 4443
  • [9] Fluorescent sensor for Hg2+ detection in aqueous solution
    Han, Aixia
    Liu, Xiaohui
    Prestwich, Glenn D.
    Zang, Ling
    SENSORS AND ACTUATORS B-CHEMICAL, 2014, 198 : 274 - 277
  • [10] A method to detect Hg2+ in vegetable via a "Turn-ON" Hg2+-Fluorescent sensor with a nanomolar sensitivity
    Kraithong, Sasiwimon
    Panchan, Waraporn
    Charoenpanich, Adisri
    Sirirak, Jitnapa
    Sahasithiwat, Somboon
    Swanglap, Pattanawit
    Promarak, Vinich
    Thamyongkit, Patchanita
    Wanichacheva, Nantanit
    JOURNAL OF PHOTOCHEMISTRY AND PHOTOBIOLOGY A-CHEMISTRY, 2020, 389