Randomized evaluation of the size 2 laryngeal tube and classical laryngeal mask airway in different head and neck positions in children under positive pressure ventilation

被引:10
作者
Biedler, Andreas [1 ]
Wrobel, Marc [2 ]
Schneider, Sven [2 ]
Soltesz, Stefan [3 ]
Ziegeler, Stephan [4 ]
Grundmann, Ulrich [2 ]
机构
[1] Katholisches Klinikum Essen, Klin Anasthesie & Intens Med, D-45329 Essen, Germany
[2] Univ Klinikum Saarlandes, Klin Anasthesie Intens Med Notfallmed & Schmerzth, Homburg, Saar, Germany
[3] Kreiskrankenhaus Dormagen, Klin Anasthesie Intens & Notfallmed, Dormagen, Germany
[4] Klinikum Ibbenburen, Klin Anasthesie Operat Intens Med Schmerztherapie, Ibbenburen, Germany
关键词
Supraglottic; Pediatric anesthesia; Leak pressure; Peak pressure; Different head-neck positions; OROPHARYNGEAL LEAK PRESSURE; PEDIATRIC-PATIENTS; CUFF POSITION; DEVICES; ADENOTONSILLECTOMY; ANESTHESIA; CROSSOVER; INFANTS; FLEXION; SEAL;
D O I
10.1007/s00540-013-1583-y
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
The aim of this study was to evaluate the applicability of the laryngeal tube (LT) size 2 and the classical laryngeal mask airway (LMA) size 2 in different head-neck positions under positive pressure ventilation in children by measuring leak pressures, peak pressures and the achievable tidal volumes under positive pressure ventilation. Forty children were randomized to receive airway management by either the LT or LMA as the primary device. Leak pressures, peak pressures and tidal volumes under positive pressure ventilation were measured in the neutral, anteflection, retroversion, left-rotation and right-rotation head-neck positions. In all head-neck positions, the leak pressures were significantly higher for the LT than for the LMA (neutral 25.9 +/- A 7.0 vs. 19.1 +/- A 5.7 cmH(2)O; anteflection 29.7 +/- A 7.1 vs. 24.2 +/- A 8.9 cmH(2)O; retroversion 24.1 +/- A 7.6 vs. 17.2 +/- A 6.9 cmH(2)O). In both devices, the peak ventilation pressures were higher in the anteflection position (LT 27.1 +/- A 6.3 cmH(2)O; LMA 17.8 +/- A 6.7 cmH(2)O) than in the retroversion position (LT 13.7 +/- A 3.9 cmH(2)O; LMA 12.7 +/- A 3.6 cmH(2)O). Compared to the respirator settings, lower tidal volumes were achieved in the anteflection position (LT 65 +/- A 48 vs. 129 +/- A 38 ml, LMA 100 +/- A 21 vs. 125 +/- A 29 ml) as compared to the other positions. Based on our results, we suggest that in anaesthetized children, the size 2 LT, compared to the size 2 LMA, may be more suitable for positive pressure ventilation due to favorable leak and peak pressures. Both devices can be safely used in head-neck positions other than neutral. Most disadvantageous with regards to the measured parameters was the anteflection position, especially for the LT.
引用
收藏
页码:657 / 662
页数:6
相关论文
共 24 条
[1]   A comparison of the disposable vs the reusable laryngeal tube in paralysed adult patients [J].
Amini, A. ;
Zand, F. ;
Sadeghi, S. E. .
ANAESTHESIA, 2007, 62 (11) :1167-1170
[2]   THE LARYNGEAL MASK - A NEW CONCEPT IN AIRWAY MANAGEMENT [J].
BRAIN, AIJ .
BRITISH JOURNAL OF ANAESTHESIA, 1983, 55 (08) :801-805
[3]   Randomized comparison of laryngeal tube with classic laryngeal mask airway for anaesthesia with controlled ventilation [J].
Cook, TM ;
McCormick, B ;
Asai, T .
BRITISH JOURNAL OF ANAESTHESIA, 2003, 91 (03) :373-378
[4]   LMA ProSealTM vs. i-GelTM in ventilated children: A randomised, crossover study using the size 2 mask [J].
Gasteiger, L. ;
Brimacombe, J. ;
Oswald, E. ;
Perkhofer, D. ;
Tonin, A. ;
Keller, C. ;
Tiefenthaler, W. .
ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2012, 56 (10) :1321-1324
[5]   Prospective, randomized comparison of laryngeal tube and laryngeal mask airway in pediatric patients [J].
Genzwuerker, H. V. ;
Fritz, A. ;
Hinkelbein, J. ;
Finteis, T. ;
Schlaefer, A. ;
Schaeffer, M. ;
Thil, E. ;
Rapp, H. J. .
PEDIATRIC ANESTHESIA, 2006, 16 (12) :1251-1256
[6]   Cuff filling volumes for pediatric classic laryngeal mask airways: comparison of clinical end points versus adjusted cuff pressure [J].
Ghai, Babita ;
Sethi, Sameer ;
Ram, Jagat ;
Wig, Jyotsna .
PEDIATRIC ANESTHESIA, 2013, 23 (02) :122-126
[7]   The size 11/2 ProSeal™ laryngeal mask airway in infants:: A randomized, crossover investigation with the Classic™ laryngeal mask airway [J].
Goldmann, K ;
Roettger, C ;
Wulf, H .
ANESTHESIA AND ANALGESIA, 2006, 102 (02) :405-410
[8]   Safety of laryngeal mask airway and short-stay practice in office-based adenotonsillectomy [J].
Gravningsbraten, R. ;
Nicklasson, B. ;
Raeder, J. .
ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2009, 53 (02) :218-222
[9]   Higher airway seal does not imply adequate positioning of laryngeal mask airways in paediatric patients [J].
Inagawa, G ;
Okuda, K ;
Miwa, T ;
Hiroki, K .
PAEDIATRIC ANAESTHESIA, 2002, 12 (04) :322-326
[10]  
Keller C, 2004, CAN J ANAESTH, V51, P834, DOI 10.1007/BF03018460