Mechanical axial flow blood pump to support cavopulmonary circulation

被引:14
作者
Throckmorton, A. L. [1 ]
Kapadia, J. [1 ]
Madduri, D. [1 ]
机构
[1] Virginia Commonwealth Univ, Dept Mech Engn, Richmond, VA 23284 USA
基金
美国国家科学基金会;
关键词
Pediatric mechanical circulatory support; Pediatric ventricular assist device; Pediatric circulatory support; Ventricular assist device; Single ventricle physiology; Cavopulmonary assist device; Fontan conversion; Heart pump; Blood pump; Artificial right ventricle;
D O I
10.1177/039139880803101107
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We are developing a collapsible, percutaneously inserted, axial flow blood pump to support the cavopulmonary circulation in infants with a failing single ventricle physiology. An initial design of the impeller for this axial flow blood pump was performed using computational fluid dynamics analysis, including pressure-flow characteristics, scalar stress estimations, blood damage indices, and fluid force predictions. A plastic prototype was constructed for hydraulic performance testing, and these experimental results were compared with the numerical predictions. The numerical predictions and experimental findings of the pump performance demonstrated a pressure generation of 2-16 mm Hg for 50-750 ml/min over 5,500-7,500 RPM with deviation found at lower rotational speeds. The axial fluid forces remained below 0.1 N, and the radial fluid forces were determined to be virtually zero due to the centered impeller case. The scalar stress levels remained below 250 Pa for all operating conditions. Blood damage analysis yielded a mean residence time of the released particles, which was found to be less than 0.4 seconds for both flow rates that were examined, and a maximum residence time was determined to be less than 0.8 seconds. We are in the process of designing a cage with hydrodynamically shaped filament blades to act as a diffuser and optimizing the impeller blade shape to reduce the flow vorticity at the pump outlet. This blood pump will improve the clinical treatment of patients with failing Fontan physiology and provide a unique catheter-based therapeutic approach as a bridge to recovery or transplantation. (Int J Artif Organs 2008; 31: 970-82)
引用
收藏
页码:970 / 982
页数:13
相关论文
共 50 条
  • [31] NUMERICAL AND EXPERIMENTAL INVESTIGATION ON THE INFLUENCE OF BLADES GAP FLOW ON AXIAL BLOOD PUMP PERFORMANCE
    Liu, Guangmao
    Jin, Donghai
    Wang, Mengyu
    Gui, Xingmin
    PROCEEDINGS OF THE ASME/JSME/KSME JOINT FLUIDS ENGINEERING CONFERENCE, 2019, VOL 3B, 2019,
  • [32] Numerical Investigation of the Influence of Blade Radial Gap Flow on Axial Blood Pump Performance
    Liu, Guang-Mao
    Jin, Dong-Hai
    Zhou, Jian-Ye
    Zhang, Yan
    Chen, Hai-bo
    Sun, Han-Song
    Hu, Sheng-shou
    Gui, Xing-Min
    ASAIO JOURNAL, 2019, 65 (01) : 59 - 69
  • [33] Numerical analysis of different cardiac functions and support modes on blood damage potential in an axial pump
    Li, Shulei
    Jin, Donghai
    Gui, Xingmin
    Liu, Guangmao
    Jiang, Xihang
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2023, 46 (04) : 215 - 225
  • [34] Computer and physical modeling of blood circulation pump support for a new field of application in palliative surgery
    Malota, Z.
    Nawrat, Z.
    Kostka, P.
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2007, 30 (12) : 1068 - 1074
  • [35] Computational Characterization of Flow and Hemolytic Performance of the UltraMag Blood Pump for Circulatory Support
    Taskin, M. Ertan
    Fraser, Katharine H.
    Zhang, Tao
    Gellman, Barry
    Fleischli, Andi
    Dasse, Kurt A.
    Griffith, Bartley P.
    Wu, Zhongjun J.
    ARTIFICIAL ORGANS, 2010, 34 (12) : 1099 - 1113
  • [36] Bench Tests of an Implantable Axial Blood Pump
    Konysheva E.G.
    Kudinov V.L.
    Dozorov K.N.
    Kalyanin S.A.
    Kuz'min G.S.
    Biomedical Engineering, 2011, 44 (06) : 222 - 227
  • [37] LARGE-EDDY AND UNSTEADY REYNOLDS-AVERAGED NAVIER-STOKES SIMULATIONS OF AN AXIAL FLOW PUMP FOR CARDIAC SUPPORT
    Torner, Benjamin
    Hallier, Sebastian
    Witte, Matthias
    Wurm, Frank-Hendrik
    PROCEEDINGS OF THE ASME TURBO EXPO: TURBINE TECHNICAL CONFERENCE AND EXPOSITION, 2017, VOL 2B, 2017,
  • [38] The design of the magnetic and hydraulic suspension system on an axial blood pump and the analysis of its mechanical properties
    Tang, Xiaoyan
    Yun, Zhong
    Xu, Junrui
    Cai, Chao
    2017 IEEE 2ND ADVANCED INFORMATION TECHNOLOGY, ELECTRONIC AND AUTOMATION CONTROL CONFERENCE (IAEAC), 2017, : 1994 - 1997
  • [39] Mechanical Support of the Failing Fontan Circulation
    Mascio, Christopher E.
    SEMINARS IN THORACIC AND CARDIOVASCULAR SURGERY, 2021, 33 (02) : 454 - 458
  • [40] Optimizing the design of axial flow pump blades based on fluid characteristics
    Zhu, Lin
    Yu, Qifeng
    Yu, Lu
    Wang, Lizhen
    Yang, Yuncong
    Shen, Peng
    Fan, Yubo
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2024,