Mechanical axial flow blood pump to support cavopulmonary circulation

被引:14
作者
Throckmorton, A. L. [1 ]
Kapadia, J. [1 ]
Madduri, D. [1 ]
机构
[1] Virginia Commonwealth Univ, Dept Mech Engn, Richmond, VA 23284 USA
基金
美国国家科学基金会;
关键词
Pediatric mechanical circulatory support; Pediatric ventricular assist device; Pediatric circulatory support; Ventricular assist device; Single ventricle physiology; Cavopulmonary assist device; Fontan conversion; Heart pump; Blood pump; Artificial right ventricle;
D O I
10.1177/039139880803101107
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We are developing a collapsible, percutaneously inserted, axial flow blood pump to support the cavopulmonary circulation in infants with a failing single ventricle physiology. An initial design of the impeller for this axial flow blood pump was performed using computational fluid dynamics analysis, including pressure-flow characteristics, scalar stress estimations, blood damage indices, and fluid force predictions. A plastic prototype was constructed for hydraulic performance testing, and these experimental results were compared with the numerical predictions. The numerical predictions and experimental findings of the pump performance demonstrated a pressure generation of 2-16 mm Hg for 50-750 ml/min over 5,500-7,500 RPM with deviation found at lower rotational speeds. The axial fluid forces remained below 0.1 N, and the radial fluid forces were determined to be virtually zero due to the centered impeller case. The scalar stress levels remained below 250 Pa for all operating conditions. Blood damage analysis yielded a mean residence time of the released particles, which was found to be less than 0.4 seconds for both flow rates that were examined, and a maximum residence time was determined to be less than 0.8 seconds. We are in the process of designing a cage with hydrodynamically shaped filament blades to act as a diffuser and optimizing the impeller blade shape to reduce the flow vorticity at the pump outlet. This blood pump will improve the clinical treatment of patients with failing Fontan physiology and provide a unique catheter-based therapeutic approach as a bridge to recovery or transplantation. (Int J Artif Organs 2008; 31: 970-82)
引用
收藏
页码:970 / 982
页数:13
相关论文
共 50 条
  • [21] Energetics of blood flow in Fontan circulation under VAD support
    Telyshev, Dmitry
    Denisov, Maxim
    Markov, Aleksandr
    Fresiello, Libera
    Verbelen, Tom
    Selishchev, Sergey
    ARTIFICIAL ORGANS, 2020, 44 (01) : 50 - 57
  • [22] A new design and computational fluid dynamics study of an implantable axial blood pump
    Mojtaba Koochaki
    Hanieh Niroomand-Oscuii
    Australasian Physical & Engineering Sciences in Medicine, 2013, 36 : 417 - 422
  • [23] A new design and computational fluid dynamics study of an implantable axial blood pump
    Koochaki, Mojtaba
    Niroomand-Oscuii, Hanieh
    AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2013, 36 (04) : 417 - 422
  • [24] Characteristics of a blood pump combining the centrifugal and axial pumping principles: The spiral pump
    Andrade, A
    Biscegli, J
    Dinkhuysen, J
    Sousa, JE
    Ohashi, Y
    Hemmings, S
    Glueck, J
    Kawahito, K
    Nose, Y
    ARTIFICIAL ORGANS, 1996, 20 (06) : 605 - 612
  • [25] Optimization of Axial Pump Characteristic Dimensions and Induced Hemolysis for Mechanical Circulatory Support Devices
    Korakianitis, Theodosios
    Rezaienia, Mohammad Amin
    Paul, Gordon
    Avital, Eldad
    Rothman, Martin
    Mozafari, Sahand
    ASAIO JOURNAL, 2018, 64 (06) : 727 - 734
  • [26] Measurement of hemodynamic changes with the axial flow blood pump installed in descending aorta
    Eiji Okamoto
    Tetsuya Yano
    Hidekazu Miura
    Yasuyuki Shiraishi
    Tomoyuki Yambe
    Yoshinori Mitamura
    Journal of Artificial Organs, 2017, 20 : 390 - 393
  • [27] Laser Flow Measurements in an Idealized Total Cavopulmonary Connection With Mechanical Circulatory Assistance
    Chopski, Steven G.
    Downs, Emily
    Haggerty, Christopher M.
    Yoganathan, Ajit P.
    Throckmorton, Amy L.
    ARTIFICIAL ORGANS, 2011, 35 (11) : 1052 - 1064
  • [28] Measurement of hemodynamic changes with the axial flow blood pump installed in descending aorta
    Okamoto, Eiji
    Yano, Tetsuya
    Miura, Hidekazu
    Shiraishi, Yasuyuki
    Yambe, Tomoyuki
    Mitamura, Yoshinori
    JOURNAL OF ARTIFICIAL ORGANS, 2017, 20 (04) : 390 - 393
  • [29] The hemodynamics and blood trauma in axial blood pump under different operating models
    Zhang, Yunpeng
    Wu, Xiangyu
    Wang, Yiming
    Liu, Hongtao
    Liu, Guang-Mao
    ARTIFICIAL ORGANS, 2022, 46 (11) : 2159 - 2170
  • [30] Hemodynamic Performance of a Miniature Axial Blood Pump Caused by Motors
    Chang, Yu
    Chen, Ningning
    Gao, Bin
    2009 3RD INTERNATIONAL CONFERENCE ON BIOINFORMATICS AND BIOMEDICAL ENGINEERING, VOLS 1-11, 2009, : 1250 - 1253