被引:14
作者
Throckmorton, A. L. [1 ]
Kapadia, J. [1 ]
Madduri, D. [1 ]
机构
[1] Virginia Commonwealth Univ, Dept Mech Engn, Richmond, VA 23284 USA
基金
美国国家科学基金会;
关键词
Pediatric mechanical circulatory support; Pediatric ventricular assist device; Pediatric circulatory support; Ventricular assist device; Single ventricle physiology; Cavopulmonary assist device; Fontan conversion; Heart pump; Blood pump; Artificial right ventricle;
D O I
10.1177/039139880803101107
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We are developing a collapsible, percutaneously inserted, axial flow blood pump to support the cavopulmonary circulation in infants with a failing single ventricle physiology. An initial design of the impeller for this axial flow blood pump was performed using computational fluid dynamics analysis, including pressure-flow characteristics, scalar stress estimations, blood damage indices, and fluid force predictions. A plastic prototype was constructed for hydraulic performance testing, and these experimental results were compared with the numerical predictions. The numerical predictions and experimental findings of the pump performance demonstrated a pressure generation of 2-16 mm Hg for 50-750 ml/min over 5,500-7,500 RPM with deviation found at lower rotational speeds. The axial fluid forces remained below 0.1 N, and the radial fluid forces were determined to be virtually zero due to the centered impeller case. The scalar stress levels remained below 250 Pa for all operating conditions. Blood damage analysis yielded a mean residence time of the released particles, which was found to be less than 0.4 seconds for both flow rates that were examined, and a maximum residence time was determined to be less than 0.8 seconds. We are in the process of designing a cage with hydrodynamically shaped filament blades to act as a diffuser and optimizing the impeller blade shape to reduce the flow vorticity at the pump outlet. This blood pump will improve the clinical treatment of patients with failing Fontan physiology and provide a unique catheter-based therapeutic approach as a bridge to recovery or transplantation. (Int J Artif Organs 2008; 31: 970-82)
引用
收藏
页码:970 / 982
页数:13
相关论文
共 50 条
  • [1] Interaction of an Idealized Cavopulmonary Circulation With Mechanical Circulatory Assist Using an Intravascular Rotary Blood Pump
    Bhavsar, Sonya S.
    Moskowitz, William B.
    Throckmorton, Amy L.
    ARTIFICIAL ORGANS, 2010, 34 (10) : 816 - 827
  • [2] Flexible impeller blades in an axial flow pump for intravascular cavopulmonary assistance of the fontan physiology
    Throckmorton A.L.
    Kapadia J.Y.
    Carr J.P.
    Powell C.M.
    Tate R.D.
    Traynham D.V.
    Cardiovascular Engineering and Technology, 2010, 1 (4) : 244 - 255
  • [3] Design of a Protective Cage for an Intravascular Axial Flow Blood Pump to Mechanically Assist the Failing Fontan
    Throckmorton, Amy L.
    Kishore, Ravi A.
    ARTIFICIAL ORGANS, 2009, 33 (08) : 611 - 621
  • [4] Numerical, Hydraulic, and Hemolytic Evaluation of an Intravascular Axial Flow Blood Pump to Mechanically Support Fontan Patients
    Amy L. Throckmorton
    Jugal Y. Kapadia
    Steven G. Chopski
    Sonya S. Bhavsar
    William B. Moskowitz
    Scott D. Gullquist
    James J. Gangemi
    Christopher M. Haggerty
    Ajit P. Yoganathan
    Annals of Biomedical Engineering, 2011, 39 : 324 - 336
  • [5] Numerical, Hydraulic, and Hemolytic Evaluation of an Intravascular Axial Flow Blood Pump to Mechanically Support Fontan Patients
    Throckmorton, Amy L.
    Kapadia, Jugal Y.
    Chopski, Steven G.
    Bhavsar, Sonya S.
    Moskowitz, William B.
    Gullquist, Scott D.
    Gangemi, James J.
    Haggerty, Christopher M.
    Yoganathan, Ajit P.
    ANNALS OF BIOMEDICAL ENGINEERING, 2011, 39 (01) : 324 - 336
  • [6] A long-term mechanical cavopulmonary support device for patients with Fontan circulation
    Granegger, Marcus
    Thamsen, Bente
    Hubmann, Emanuel J.
    Choi, Young
    Beck, Dominik
    Buechel, Emanuela Valsangiacomo
    Voutat, Michael
    Schweiger, Martin
    Meboldt, Mirko
    Hubler, Michael
    MEDICAL ENGINEERING & PHYSICS, 2019, 70 : 9 - 18
  • [7] Hydraulic Testing of Intravascular Axial Flow Blood Pump Designs With a Protective Cage of Filaments for Mechanical Cavopulmonary Assist
    Kapadia, Jugal Y.
    Pierce, Kathryn C.
    Poupore, Amy K.
    Throckmorton, Amy L.
    ASAIO JOURNAL, 2010, 56 (01) : 17 - 23
  • [8] Miniaturization of a Magnetically Levitated Axial Flow Blood Pump
    Cheng, Shanbao
    Olles, Mark W.
    Olsen, Don B.
    Joyce, Lyle D.
    Day, Steven W.
    ARTIFICIAL ORGANS, 2010, 34 (10) : 807 - 815
  • [9] Steady Flow Analysis of Mechanical Cavopulmonary Assistance in MRI-Derived Patient-Specific Fontan Configurations
    Downs, Emily A.
    Moskowitz, William B.
    Throckmorton, Amy L.
    ARTIFICIAL ORGANS, 2012, 36 (11) : 972 - 980
  • [10] Mechanically Assisted Total Cavopulmonary Connection With an Axial Flow Pump: Computational and In Vivo Study
    Gandolfo, Fabrizio
    Brancaccio, Gianluca
    Donatiello, Salvatore
    Filippelli, Sergio
    Perri, Gianluigi
    Iannace, Enrico
    D'Amario, Domenico
    Testa, Giuseppina
    D'Avenio, Giuseppe
    Grigioni, Mauro
    Amodeo, Antonio
    ARTIFICIAL ORGANS, 2016, 40 (01) : 43 - 49