MEASUREMENT OF THE EFFICIENCY OF EVACUATED TUBE SOLAR COLLECTORS UNDER VARIOUS OPERATING CONDITIONS

被引:11
|
作者
Zubriski, S. E. [1 ]
Dick, K. J. [2 ]
机构
[1] Univ Manitoba, Dept Biosyst Engn, Winnipeg, MB, Canada
[2] Univ Manitoba, Dept Biosyst Engn, Alternative Village, Winnipeg, MB, Canada
来源
JOURNAL OF GREEN BUILDING | 2012年 / 7卷 / 03期
关键词
solar collector; evacuated tube; solar hot water; PERFORMANCE;
D O I
10.3992/jgb.7.3.114
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The operating efficiency of evacuated tubes themselves under varying environmental conditions and installation scenarios, independent of water and space heating auxiliary equipment, are not readily available values. Further, Manitoba specific data has not been established. The purpose of this research program was to measure the efficiency of evacuated tube solar collectors under various operating conditions including: the angle of inclination towards the incident solar radiation, heat transfer fluid flow rate, glazing installation, and number of evacuated tubes. The operating conditions and configurations were chosen to represent realistic or probable installation scenarios and environmental conditions. Furthermore, the research aimed to identify the suitability of evacuated tube solar collectors to each of the scenarios. These design values are of use for appropriate sizing of water or space heating systems, system configuration and optimization, and calculation of return on investment. The scope of the research project was limited to the efficiency of various configurations of a 32-tube panel, not the entire solar domestic hot water or space heating system. Thus, factors such as heat loss in the tubing, solar storage tank, and heat exchanger efficiency were not investigated. The findings indicated that efficiency varied by approximately 5% between the different collector configurations, as observed from the overlay graph of results. When the efficiency of a collector is considered within a system it is proposed that effectiveness may be a better measure of overall performance.
引用
收藏
页码:114 / 130
页数:17
相关论文
共 50 条
  • [41] Testing of solar thermal collectors under transient conditions
    Osorio, Tiago
    Carvalho, Maria Joao
    1ST INTERNATIONAL CONFERENCE ON SOLAR HEATING AND COOLING FOR BUILDINGS AND INDUSTRY (SHC 2012), 2012, 30 : 1344 - 1353
  • [42] Annual energy, exergy, and efficiency analyses for conical solar still combined with N number of evacuated collectors
    Kumar, Abhishek
    Kumar, Rajesh
    ENVIRONMENTAL PROGRESS & SUSTAINABLE ENERGY, 2024,
  • [43] Thermodynamic studies of a novel heat pipe evacuated tube solar collectors based integrated process for hydrogen production
    Corumlu, Vahit
    Ozsoy, Ahmet
    Ozturk, Murat
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2018, 43 (02) : 1060 - 1070
  • [44] Experimental investigation of a solar-heated direct contact membrane distillation system using evacuated tube collectors
    Bamasag, Ahmad
    Alqahtani, Talal
    Sinha, Shahnawaz
    Ghaffour, Noreddine
    Phelan, Patrick
    DESALINATION, 2020, 487
  • [45] Numerical investigation of building integrated solar thermal collectors under diverse conditions
    Georgiou, Loucas
    Souliotis, Manolis
    Leontiou, Theodoros
    Sadauskiene, Jolanta
    Vaiciunas, Juozas
    Papaefthimiou, Spiros
    Fokaides, Paris A.
    INTERNATIONAL JOURNAL OF SUSTAINABLE ENERGY, 2023, 42 (01) : 1042 - 1062
  • [46] Comparative Studies on the Efficiency of Solar Flat-plate Collector and Evacuated Tube Collector
    Yan, Huilei
    Zhang, Hua
    Shao, Qiuping
    ADVANCES IN ENERGY SCIENCE AND TECHNOLOGY, PTS 1-4, 2013, 291-294 : 3 - 8
  • [47] The influence of flow tube vibrations over the efficiency of solar water heating collectors
    Ciocanea, Adrian
    Buretea, Dorin Laurentiu
    SUSTAINABLE SOLUTIONS FOR ENERGY AND ENVIRONMENT, EENVIRO 2016, 2017, 112 : 330 - 335
  • [48] Comparison and evaluation of energetic and exergetic performance of an evacuated tube solar collector using various nanofluid
    Tong, Yijie
    Wang, Ruijin
    Wang, Shifeng
    Wang, Huijiao
    Huang, Lizhong
    Shao, Chun
    Jin, Xiao
    Xue, Bing
    Zhu, Zefei
    PROCESS SAFETY AND ENVIRONMENTAL PROTECTION, 2023, 174 : 585 - 594
  • [49] Examination of a solar desalination system equipped with an air bubble column humidifier, evacuated tube collectors and thermosyphon heat pipes
    Behnam, Pooria
    Shafii, Mohammad Behshad
    DESALINATION, 2016, 397 : 30 - 37
  • [50] Experimental Comparison of Flat Plate and Evacuated Tube Solar Thermal Collectors for Domestic Hot Water Preparation in Education Facilities
    Moldovan, Macedon
    Visa, Ion
    Burduhos, Bogdan Gabriel
    JOURNAL OF SUSTAINABLE DEVELOPMENT OF ENERGY WATER AND ENVIRONMENT SYSTEMS-JSDEWES, 2020, 8 (02): : 293 - 303