MEASUREMENT OF THE EFFICIENCY OF EVACUATED TUBE SOLAR COLLECTORS UNDER VARIOUS OPERATING CONDITIONS

被引:11
|
作者
Zubriski, S. E. [1 ]
Dick, K. J. [2 ]
机构
[1] Univ Manitoba, Dept Biosyst Engn, Winnipeg, MB, Canada
[2] Univ Manitoba, Dept Biosyst Engn, Alternative Village, Winnipeg, MB, Canada
来源
JOURNAL OF GREEN BUILDING | 2012年 / 7卷 / 03期
关键词
solar collector; evacuated tube; solar hot water; PERFORMANCE;
D O I
10.3992/jgb.7.3.114
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The operating efficiency of evacuated tubes themselves under varying environmental conditions and installation scenarios, independent of water and space heating auxiliary equipment, are not readily available values. Further, Manitoba specific data has not been established. The purpose of this research program was to measure the efficiency of evacuated tube solar collectors under various operating conditions including: the angle of inclination towards the incident solar radiation, heat transfer fluid flow rate, glazing installation, and number of evacuated tubes. The operating conditions and configurations were chosen to represent realistic or probable installation scenarios and environmental conditions. Furthermore, the research aimed to identify the suitability of evacuated tube solar collectors to each of the scenarios. These design values are of use for appropriate sizing of water or space heating systems, system configuration and optimization, and calculation of return on investment. The scope of the research project was limited to the efficiency of various configurations of a 32-tube panel, not the entire solar domestic hot water or space heating system. Thus, factors such as heat loss in the tubing, solar storage tank, and heat exchanger efficiency were not investigated. The findings indicated that efficiency varied by approximately 5% between the different collector configurations, as observed from the overlay graph of results. When the efficiency of a collector is considered within a system it is proposed that effectiveness may be a better measure of overall performance.
引用
收藏
页码:114 / 130
页数:17
相关论文
共 50 条
  • [31] Thermal characteristics of evacuated tube solar collectors with coil inside: An experimental study and evolutionary algorithms
    Sadeghi, Gholamabbas
    Najafzadeh, Mohammad
    Ameri, Mehran
    RENEWABLE ENERGY, 2020, 151 : 575 - 588
  • [32] The Comparison of Solar Energy Gaining Effectiveness between Flat Plate Collectors and Evacuated Tube Collectors with Heat Pipe: Case Study
    Olczak, Piotr
    Matuszewska, Dominika
    Zabaglo, Jadwiga
    ENERGIES, 2020, 13 (07)
  • [33] An Experimental Study of the Solar Collection Performance of Liquid-Type Solar Collectors under Various Weather Conditions
    Choi, Youngjin
    ENERGIES, 2018, 11 (07):
  • [34] Performance analysis of evacuated tubes with thermosyphon heat pipe solar collector integrated with compound parabolic concentrator under different operating conditions
    Govindasamy, Kumaresan
    Palanivel, Vijayakumar
    Meena, Radhey Shyam
    Muthusamy, Suresh
    Panchal, Hitesh
    Shah, Mohd. Asif
    Siddiqui, Md Irfanul Haque
    ENERGY EXPLORATION & EXPLOITATION, 2024, 42 (01) : 231 - 249
  • [35] Improving the performance of a hybrid solar desalination system under various operating conditions
    Alsehli, Mishal
    Essa, Fadl A.
    Omara, Z. M.
    Othman, Mahmoud M.
    Elsheikh, Ammar H.
    Alwetaishi, Mamdooh
    Alghamdi, Saleh
    Saleh, B.
    PROCESS SAFETY AND ENVIRONMENTAL PROTECTION, 2022, 162 : 706 - 720
  • [36] Thermal performance enhancement of flat-plate and evacuated tube solar collectors using nanofluid: A review
    Muhammad, Mahmud Jamil
    Muhammad, Isa Adamu
    Sidik, Nor Azwadi Che
    Yazid, Muhammad Noor Afiq Witri Muhammad
    INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2016, 76 : 6 - 15
  • [37] Experimental evaluation of the efficiency of a solar tube collector evacuated with and without heat pipe
    Eufracio Arias, Wilder Efrain
    Abregu Rodriguez, Nathaly Ibeth
    Rodriguez Espinoza, Dayana
    FUENTES EL REVENTON ENERGETICO, 2019, 17 (01): : 7 - 17
  • [38] Thermal Modeling of Water-in-Tube Type Evacuated Tube Solar Collectors to Predict Outlet Water Temperature: An Experimental Validation
    Singh, Pushpendra
    Gaur, M. K.
    Tiwari, G. N.
    Kumar, Anil
    JOURNAL OF SOLAR ENERGY ENGINEERING-TRANSACTIONS OF THE ASME, 2023, 145 (02):
  • [39] AN EXPERIMENTAL INVESTIGATION OF EVACUATED TUBE SOLAR COLLECTOR UNDER AL-HILLA CLIMATE CONDITION
    Khudair, Nagham Yass
    Hussein, Ahmed Kadhim
    FRONTIERS IN HEAT AND MASS TRANSFER, 2022, 19
  • [40] Testing of solar thermal collectors under transient conditions
    Osorio, Tiago
    Carvalho, Maria Joao
    SOLAR ENERGY, 2014, 104 : 71 - 81