MEASUREMENT OF THE EFFICIENCY OF EVACUATED TUBE SOLAR COLLECTORS UNDER VARIOUS OPERATING CONDITIONS

被引:11
|
作者
Zubriski, S. E. [1 ]
Dick, K. J. [2 ]
机构
[1] Univ Manitoba, Dept Biosyst Engn, Winnipeg, MB, Canada
[2] Univ Manitoba, Dept Biosyst Engn, Alternative Village, Winnipeg, MB, Canada
来源
JOURNAL OF GREEN BUILDING | 2012年 / 7卷 / 03期
关键词
solar collector; evacuated tube; solar hot water; PERFORMANCE;
D O I
10.3992/jgb.7.3.114
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The operating efficiency of evacuated tubes themselves under varying environmental conditions and installation scenarios, independent of water and space heating auxiliary equipment, are not readily available values. Further, Manitoba specific data has not been established. The purpose of this research program was to measure the efficiency of evacuated tube solar collectors under various operating conditions including: the angle of inclination towards the incident solar radiation, heat transfer fluid flow rate, glazing installation, and number of evacuated tubes. The operating conditions and configurations were chosen to represent realistic or probable installation scenarios and environmental conditions. Furthermore, the research aimed to identify the suitability of evacuated tube solar collectors to each of the scenarios. These design values are of use for appropriate sizing of water or space heating systems, system configuration and optimization, and calculation of return on investment. The scope of the research project was limited to the efficiency of various configurations of a 32-tube panel, not the entire solar domestic hot water or space heating system. Thus, factors such as heat loss in the tubing, solar storage tank, and heat exchanger efficiency were not investigated. The findings indicated that efficiency varied by approximately 5% between the different collector configurations, as observed from the overlay graph of results. When the efficiency of a collector is considered within a system it is proposed that effectiveness may be a better measure of overall performance.
引用
收藏
页码:114 / 130
页数:17
相关论文
共 50 条
  • [1] Optimum number and arrangement of evacuated-tube solar collectors under various operating conditions
    Kotb, Amr
    Elsheniti, Mahmoud B.
    Elsamni, Osama A.
    ENERGY CONVERSION AND MANAGEMENT, 2019, 199
  • [2] ENERGY AND EXERGY EFFICIENCY OF HEAT PIPE EVACUATED TUBE SOLAR COLLECTORS
    Jafarkazemi, Farzad
    Ahmadifard, Emad
    Abdi, Hossein
    THERMAL SCIENCE, 2016, 20 (01): : 327 - 335
  • [3] Test of solar adsorption air-conditioning powered by evacuated tube collectors under the climatic conditions of Iraq
    Lattieff, Farkad A.
    Atiya, Mohammed A.
    Al-Hemiri, Adel A.
    RENEWABLE ENERGY, 2019, 142 : 20 - 29
  • [4] An improved procedure for the experimental characterization of optical efficiency in evacuated tube solar collectors
    Zambolin, E.
    Del Col, D.
    RENEWABLE ENERGY, 2012, 43 : 37 - 46
  • [5] Experimental Investigation of the Performance of Evacuated-Tube Solar Collectors under Eastern Mediterranean Climatic Conditions
    Hayek, Michel
    Assaf, Johnny
    Lteif, William
    IMPACT OF INTEGRATED CLEAN ENERGY ON THE FUTURE OF THE MEDITERRANEAN ENVIRONMENT, 2011, 6 : 618 - 626
  • [6] Thermal modeling of evacuated tube solar air collectors
    Paradis, Pierre-Luc
    Rousse, Daniel R.
    Halle, Stephane
    Lamarche, Louis
    Quesada, Guillermo
    SOLAR ENERGY, 2015, 115 : 708 - 721
  • [7] Improving thermal efficiency using vibration monitoring and nanofluids in solar evacuated tube collectors
    Sathish, T.
    Saravanan, R.
    RESULTS IN ENGINEERING, 2025, 25
  • [8] Experimental and theoretical performance evaluation of evacuated tube collectors under mediterranean climate conditions
    Nitsas, M. T.
    Koronaki, I. P.
    THERMAL SCIENCE AND ENGINEERING PROGRESS, 2018, 8 : 457 - 469
  • [9] Evacuated tube solar collectors integrated with phase change materials
    Papadimitratos, Alexios
    Sobhansarbandi, Sarvenaz
    Pozdin, Vladimir
    Zakhidov, Anvar
    Hassanipour, Fatemeh
    SOLAR ENERGY, 2016, 129 : 10 - 19
  • [10] Thermoeconomic and environmental analysis of solar flat plate and evacuated tube collectors in cold climatic conditions
    Sokhansefat, Tahmineh
    Kasaeian, Alibakhsh
    Rahmani, Kiana
    Heidari, Ameneh Haji
    Aghakhani, Faezeh
    Mahian, Omid
    RENEWABLE ENERGY, 2018, 115 : 501 - 508