4D computed tomography scans for conformal thoracic treatment planning: is a single scan sufficient to capture thoracic tumor motion?

被引:4
|
作者
Tseng, Yolanda D. [1 ]
Wootton, Landon [1 ]
Nyflot, Matthew [1 ]
Apisarnthanarax, Smith [1 ]
Rengan, Ramesh [1 ]
Bloch, Charles [1 ]
Sandison, George [1 ]
St James, Sara [2 ]
机构
[1] Univ Washington, Seattle, WA 98195 USA
[2] Massachusetts Gen Hosp, Boston, MA 02114 USA
关键词
4DCT; motion management; radiation therapy; INTERNAL TARGET VOLUME; LYMPH-NODE MOVEMENT; LUNG-TUMORS; RESPIRATORY MOTION; RADIOTHERAPY; SIMULATION; QUANTIFICATION; TRACKING;
D O I
10.1088/1361-6560/aaa44e
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Four dimensional computed tomography (4DCT) scans are routinely used in radiation therapy to determine the internal treatment volume for targets that are moving (e.g. lung tumors). The use of these studies has allowed clinicians to create target volumes based upon the motion of the tumor during the imaging study. The purpose of this work is to determine if a target volume based on a single 4DCT scan at simulation is sufficient to capture thoracic motion. Phantom studies were performed to determine expected differences between volumes contoured on 4DCT scans and those on the evaluation CT scans (slow scans). Evaluation CT scans acquired during treatment of 11 patients were compared to the 4DCT scans used for treatment planning. The images were assessed to determine if the target remained within the target volume determined during the first 4DCT scan. A total of 55 slow scans were compared to the 11 planning 4DCT scans. Small differences were observed in phantom between the 4DCT volumes and the slow scan volumes, with a maximum of 2.9%, that can be attributed to minor differences in contouring and the ability of the 4DCT scan to adequately capture motion at the apex and base of the motion trajectory. Larger differences were observed in the patients studied, up to a maximum volume difference of 33.4%. These results demonstrate that a single 4DCT scan is not adequate to capture all thoracic motion throughout treatment.
引用
收藏
页数:7
相关论文
共 23 条
  • [21] Clinical use of iterative 4D-cone beam computed tomography reconstructions to investigate respiratory tumor motion in lung cancer patients
    Schmidt, Mai L.
    Poulsen, Per R.
    Toftegaard, Jakob
    Hoffmann, Lone
    Hansen, David
    Sorensen, Thomas S.
    ACTA ONCOLOGICA, 2014, 53 (08) : 1107 - 1113
  • [22] Real-Time Tumor Motion Tracking in 3D Using Planning 4D CT Images during Image-Guided Radiation Therapy
    Choi, Jang-Hwan
    Lee, Sooyeul
    ALGORITHMS, 2018, 11 (10):
  • [23] Time-Adjusted Internal Target Volume: A Novel Approach Focusing on Heterogeneity of Tumor Motion Based on 4-Dimensional Computed Tomography Imaging for Radiation Therapy Planning of Lung Cancer
    Nishibuchi, Ikuno
    Kimura, Tomoki
    Nakashima, Takeo
    Ochi, Yusuke
    Takahashi, Ippei
    Doi, Yoshiko
    Kenjo, Masahiro
    Kaneyasu, Yuko
    Ozawa, Syuichi
    Murakami, Yuji
    Wadasaki, Koichi
    Nagata, Yasushi
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2014, 89 (05): : 1129 - 1137