Sensing System for Intra-Abdominal Pressure Measurement

被引:0
作者
Toth, Teodor [1 ]
Michalikova, Monika [1 ]
Zivcak, Jozef [1 ]
机构
[1] Tech Univ Kosice, Fac Mech Engn, Dept Biomed Engn & Measurement, Kosice 04200, Slovakia
关键词
intra-abdominal pressure; measurement; sensors;
D O I
暂无
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The development of technology and information technology offers new possibilities for detecting intra-abdominal pressure (IAP) in critically ill patients. Presently, non-invasive measuring through the monitoring of pressure in the bladder has begun to be promoted. Studies on monitoring pressure in the urinary tract point to a high level of correlation with pressure in the abdominal cavity. These measures are currently conducted in the majority of workplaces by manual measurement in specified time intervals. In this article the verification of a monitoring system for measuring IAP is described, which is part of a proposed system for automatisation of IAP detection.
引用
收藏
页码:191 / 202
页数:12
相关论文
共 50 条
  • [41] Effect of intra-abdominal pressure on respiratory mechanics
    Pelosi, P.
    Quintel, M.
    Malbrain, M. L. N. G.
    ACTA CLINICA BELGICA, 2007, 62 : 78 - 88
  • [42] The role of intra-abdominal pressure in spinal unloading
    Daggfeldt, K
    Thorstensson, A
    JOURNAL OF BIOMECHANICS, 1997, 30 (11-12) : 1149 - 1155
  • [43] Intra-Abdominal Pressure: Why Are You Not Measuring It?
    Cheatham, Michael L.
    CRITICAL CARE MEDICINE, 2014, 42 (02) : 467 - 469
  • [44] Influence of volume increase on intra-abdominal pressure
    Schachtrupp, A.
    ANAESTHESIST, 2009, 58 (05): : 532 - 536
  • [45] Abdominal Wall Movements Predict Intra-Abdominal Pressure Changes in Rats: A Novel Non-Invasive Intra-Abdominal Pressure Detection Method
    Vincent, Deirdre
    Mietzsch, Stefan
    Braun, Wolfgang
    Trochimiuk, Magdalena
    Reinshagen, Konrad
    Boettcher, Michael
    Lugli, Licia
    CHILDREN-BASEL, 2023, 10 (08):
  • [46] HOW TO MEASURE INTRA-ABDOMINAL PRESSURE, THE BLADDER PRESSURE METHOD
    Gelabert Payes, Laura
    Vicente Pastor, Dolores
    REVISTA ROL DE ENFERMERIA, 2008, 31 (10): : 674 - 678
  • [47] Transvesical Intra-Abdominal Pressure Measurement in Newborn: What Is the Optimal Saline Volume Instillation?
    Defontaine, Anne
    Tirel, Olivier
    Costet, Nathalie
    Beuchee, Alain
    Ozanne, Bruno
    Gaillot, Theophile
    Arnaud, Alexis Pierre
    Wodey, Eric
    PEDIATRIC CRITICAL CARE MEDICINE, 2016, 17 (02) : 144 - 149
  • [48] The effect of different reference transducer positions on intra-abdominal pressure measurement: a multicenter analysis
    De Waele, Jan J.
    De laet, Inneke
    De Keulenaer, Bart
    Widder, Sandy
    Kirkpatrick, Andrew W.
    Cresswell, Adrian B.
    Malbrain, Manu
    Bodnar, Zsolt
    Mejia-Mantilla, Jorge H.
    Reis, Richard
    Parr, Michael
    Schulze, Robert
    Compano, Sonia
    Cheatham, Michael
    INTENSIVE CARE MEDICINE, 2008, 34 (07) : 1299 - 1303
  • [49] The effect of different reference transducer positions on intra-abdominal pressure measurement: a multicenter analysis
    Jan J. De Waele
    Inneke De laet
    Bart De Keulenaer
    Sandy Widder
    Andrew W. Kirkpatrick
    Adrian B. Cresswell
    Manu Malbrain
    Zsolt Bodnar
    Jorge H. Mejia-Mantilla
    Richard Reis
    Michael Parr
    Robert Schulze
    Sonia Compano
    Michael Cheatham
    Intensive Care Medicine, 2008, 34 : 1299 - 1303
  • [50] Plateau and Transpulmonary Pressure With Elevated Intra-Abdominal Pressure or Atelectasis
    Kubiak, Brian D.
    Gatto, Louis A.
    Jimenez, Edgar J.
    Silva-Parra, Hugo
    Snyder, Kathleen P.
    Vieau, Christopher J.
    Barba, Jorge
    Nasseri-Nik, Niloofar
    Falk, Jay L.
    Nieman, Gary F.
    JOURNAL OF SURGICAL RESEARCH, 2010, 159 (01) : E17 - E24