Sensing System for Intra-Abdominal Pressure Measurement

被引:0
作者
Toth, Teodor [1 ]
Michalikova, Monika [1 ]
Zivcak, Jozef [1 ]
机构
[1] Tech Univ Kosice, Fac Mech Engn, Dept Biomed Engn & Measurement, Kosice 04200, Slovakia
关键词
intra-abdominal pressure; measurement; sensors;
D O I
暂无
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The development of technology and information technology offers new possibilities for detecting intra-abdominal pressure (IAP) in critically ill patients. Presently, non-invasive measuring through the monitoring of pressure in the bladder has begun to be promoted. Studies on monitoring pressure in the urinary tract point to a high level of correlation with pressure in the abdominal cavity. These measures are currently conducted in the majority of workplaces by manual measurement in specified time intervals. In this article the verification of a monitoring system for measuring IAP is described, which is part of a proposed system for automatisation of IAP detection.
引用
收藏
页码:191 / 202
页数:12
相关论文
共 50 条
  • [31] Measurement of intra-abdominal pressure in large incisional hernia repair to prevent abdominal compartmental syndrome
    Angelici, A. M.
    Perotti, B.
    Dezzi, C.
    Amatucci, C.
    Mancuso, G.
    Caronna, R.
    Palumbo, P.
    GIORNALE DI CHIRURGIA, 2016, 37 (01): : 31 - 36
  • [32] Harrahill’s technique: a simple screening test for intra-abdominal pressure measurement
    J. Otto
    M. Binnebösel
    K. Junge
    M. Jansen
    R. Dembinski
    V. Schumpelick
    A. Schachtrupp
    Hernia, 2010, 14 : 415 - 419
  • [33] Intra-abdominal pressure and cardiovascular system in the intensive care unit patient
    Jozwiak, M.
    Teboul, J. -L.
    Monnet, X.
    Richard, C.
    REANIMATION, 2013, 22 (02): : 137 - 145
  • [34] Harrahill's technique: a simple screening test for intra-abdominal pressure measurement
    Otto, J.
    Binneboesel, M.
    Junge, K.
    Jansen, M.
    Dembinski, R.
    Schumpelick, V.
    Schachtrupp, A.
    HERNIA, 2010, 14 (04) : 415 - 419
  • [35] Assessment of the Smartpill, a Wireless Sensor, as a Measurement Tool for Intra-Abdominal Pressure (IAP)
    Soucasse, Andrea
    Jourdan, Arthur
    Edin, Lauriane
    Meunier, Elise
    Bege, Thierry
    Masson, Catherine
    SENSORS, 2024, 24 (01)
  • [36] Going for the gold: Accuracy and precision in intra-abdominal pressure measurements?
    Teplick, R
    Hassan, M
    CRITICAL CARE MEDICINE, 2006, 34 (03) : 916 - 918
  • [37] Systematic Review of Diagnostic Sensors for Intra-Abdominal Pressure Monitoring
    Liao, Chien-Hung
    Cheng, Chi-Tung
    Chen, Chih-Chi
    Wang, Yu-Hsin
    Chiu, Hsin-Tzu
    Peng, Cheng-Chun
    Jow, Uei-Ming
    Lai, Yen-Liang
    Chen, Ya-Chuan
    Ho, Dong-Ru
    SENSORS, 2021, 21 (14)
  • [38] Intra-abdominal pressure and intra-abdominal hypertension in critically ill obstetric patients: a prospective cohort study
    Tyagi, A.
    Singh, S.
    Kumar, M.
    Sethi, A. K.
    INTERNATIONAL JOURNAL OF OBSTETRIC ANESTHESIA, 2017, 32 : 33 - 40
  • [39] Determining normal values for intra-abdominal pressure
    Chionh, Joanne J. L.
    Wei, Benjamin P. C.
    Martin, Jenepher A.
    Opdam, Helen I.
    ANZ JOURNAL OF SURGERY, 2006, 76 (12) : 1106 - 1109
  • [40] Can femoral venous pressure be used as an estimate for standard vesical intra-abdominal pressure measurement?
    Howard, A. E.
    Regli, A.
    Litton, E.
    Malbrain, M. M.
    Palermo, A-M.
    De Keulenaer, B. L.
    ANAESTHESIA AND INTENSIVE CARE, 2016, 44 (06) : 704 - 711