Repairability of CAD/CAM high-density PMMA- and composite-based polymers

被引:77
作者
Wiegand, Annette [1 ]
Stucki, Lukas [2 ]
Hoffmann, Robin [1 ]
Attin, Thomas [2 ]
Stawarczyk, Bogna [3 ]
机构
[1] Univ Gottingen, Dept Prevent Dent Periodontol & Cariol, D-37075 Gottingen, Germany
[2] Univ Zurich, Clin Prevent Dent Periodontol & Cariol, Zurich, Switzerland
[3] Univ Munich, Dept Prosthodont, Munich, Germany
关键词
CAD/CAM polymer; Repair; Adhesive; PMMA; Composite; Shear bond strength; Failure; FIXED DENTAL PROSTHESES; SURFACE CONDITIONING METHODS; LOAD-BEARING CAPACITY; REPAIR BOND STRENGTH; RESIN COMPOSITE; AGING CONDITIONS; RESTORATIONS; CEMENTS; ADHESION; COMPLEX;
D O I
10.1007/s00784-015-1411-x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective The study aimed to analyse the shear bond strength of computer-aided design and computer-aided manufacturing (CAD/CAM) polymethyl methacrylate (PMMA)- and composite-based polymer materials repaired with a conventional methacrylate-based composite after different surface pretreatments. Methods Each 48 specimens was prepared from six different CAD/CAM polymer materials (Ambarino high-class, artBloc Temp, CAD-Temp, Lava Ultimate, Telio CAD, Everest C-Temp) and a conventional dimethacrylate-based composite (Filtek Supreme XTE, control) and aged by thermal cycling (5000 cycles, 5-55 A degrees C). The surfaces were left untreated or were pretreated by mechanical roughening, aluminium oxide air abrasion or silica coating/silanization (each subgroup n = 12). The surfaces were further conditioned with an etch&rinse adhesive (OptiBond FL) before the repair composite (Filtek Supreme XTE) was adhered to the surface. After further thermal cycling, shear bond strength was tested, and failure modes were assessed. Shear bond strength was statistically analysed by two- and one-way ANOVAs and Weibull statistics, failure mode by chi(2) test (p a parts per thousand currency signaEuro parts per thousand 0.05). Results Shear bond strength was highest for silica coating/silanization > aluminium oxide air abrasion = mechanical roughening > no surface pretreatment. Independently of the repair pretreatment, highest bond strength values were observed in the control group and for the composite-based Everest C-Temp and Ambarino high-class, while PMMA-based materials (artBloc Temp, CAD-Temp and Telio CAD) presented significantly lowest values. For all materials, repair without any surface pretreatment resulted in adhesive failures only, which mostly were reduced when surface pretreatment was performed. Conclusions Repair of CAD/CAM high-density polymers requires surface pretreatment prior to adhesive and composite application. However, four out of six of the tested CAD/CAM materials did not achieve the repair bond strength of a conventional dimethacrylate-based composite.
引用
收藏
页码:2007 / 2013
页数:7
相关论文
共 23 条
[1]   Fracture strength of temporary fixed partial dentures: CAD/CAM versus directly fabricated restorations [J].
Alt, Vanessa ;
Hannig, Matthias ;
Woestmann, Bernd ;
Balkenhol, Markus .
DENTAL MATERIALS, 2011, 27 (04) :339-347
[2]  
[Anonymous], 1980, GEIGY SCI TABLES
[3]   Effect of different adhesives combined with two resin composite cements on shear bond strength to polymeric CAD/CAM materials [J].
Baehr, Nora ;
Keul, Christine ;
Edelhoff, Daniel ;
Eichberger, Marlis ;
Roos, Malgorzata ;
Gernet, Wolfgang ;
Stawarczyk, Bogna .
DENTAL MATERIALS JOURNAL, 2013, 32 (03) :492-501
[4]   Load-bearing capacity of handmade and computer-aided design-computer-aided manufacturing-fabricated three-unit fixed dental prostheses of particulate filler composite [J].
Basaran, Emine Goncu ;
Ayna, Emrah ;
Vallittu, Pekka K. ;
Lassila, Lippo V. J. .
ACTA ODONTOLOGICA SCANDINAVICA, 2011, 69 (03) :144-150
[5]   Repair of dental resin-based composites [J].
Baur, Veronika ;
Ilie, Nicoleta .
CLINICAL ORAL INVESTIGATIONS, 2013, 17 (02) :601-608
[6]  
Brendeke J, 2007, J ADHES DENT, V9, P399
[7]  
Edelhoff D, 2012, QUINTESSENCE INT, V43, P457
[8]  
Gajewski Vinícius E. S., 2012, Braz. Dent. J., V23, P508
[9]   Optical properties of manually and CAD/CAM-fabricated polymers [J].
Gueth, Jan-Frederik ;
Zuch, Timo ;
Zwinge, Sebastian ;
Engels, Joerg ;
Stimmelmayr, Michael ;
Edelhoff, Daniel .
DENTAL MATERIALS JOURNAL, 2013, 32 (06) :865-871
[10]   Treatment Concept with CAD/CAM-Fabricated High-Density Polymer Temporary Restorations [J].
Gueth, Jan-Frederik ;
Almeida E Silva, Junio S. ;
Ramberger, Marc ;
Beuer, Florian ;
Edelhoff, Daniel .
JOURNAL OF ESTHETIC AND RESTORATIVE DENTISTRY, 2012, 24 (05) :310-318