Potentiometric Determination of Loperamide Hydrochloride by Loperamide PVC Membrane and Nano-Composite Electrodes

被引:0
|
作者
Faridbod, F. [1 ,2 ]
Mizani, F. [3 ]
Ganjali, M. R. [1 ,2 ]
Norouzi, P. [1 ,2 ]
机构
[1] Univ Tehran, Fac Chem, Ctr Excellence Electrochem, Tehran, Iran
[2] Univ Tehran Med Sci, Endocrinol & Metab Res Ctr, Tehran, Iran
[3] Payame Noor Univ, Dept Chem, Tehran, Iran
来源
INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE | 2012年 / 7卷 / 08期
关键词
Loperamide; Sensor; Potentiometry; Ion-selective electrode; PVC membrane; Carbon paste; Multi-walled carbon nanotubes; CARBON-PASTE ELECTRODE; ION-SELECTIVE ELECTRODE; NANOPOROUS SILICA-GEL; ANION RECOGNITION; SCHIFFS BASE; SENSOR;
D O I
暂无
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
In this work, two new loperamide potentiometric electrodes were prepared and used for pharmaceutical analysis. In case of liquid membrane electrode, the best results were obtained from the electrode with the membrane composition of 5% ion-pair, 1% NaTPB, 30% PVC, and 64% DBP. The proposed sensor shows a Nernstian response (slope of 57.2 mV per decade) in the range of 3.0x10(-5)-1.0x10(-2) mol L-1. In case of carbon paste electrode modified by MWCNTs, calibration graph slope is about 58.5 mV per decade in the concentration range of loperamide hydrochloride 1.0x10(-5)-1.0x10(-2) mol L-1. Both sensors work well in the laboratory conditions and successfully applied in analysis of loperamide in some pharmaceutical formulations.
引用
收藏
页码:7643 / 7654
页数:12
相关论文
共 50 条
  • [31] Sertraline: Theoretical Studies and a New Potentiometric PVC Membrane Sensor for its Determination
    Saber, Amr L.
    Tuzun, Burak
    Alessa, Hussain
    Althakafy, Jalal T.
    CURRENT ANALYTICAL CHEMISTRY, 2023, 19 (03) : 262 - 271
  • [32] Potentiometric Determination of Raloxifene by PVC Membrane Sensor
    Ganjali, Mohammad Reza
    Aghili, Sara
    Pirali-Hamedani, Morteza
    Norouzi, Parviz
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2012, 7 (11): : 10394 - 10403
  • [33] PVC membrane sensors for potentiometric determination of acebutolol
    Mostafa, Gamal Abdel-Hafiz
    Hefnawy, Mohamed Mahmoud
    Al-Majed, Abdulrahman
    SENSORS, 2007, 7 (12): : 3272 - 3286
  • [34] PVC Membrane Sensor for Potentiometric Determination of Dicyclomine in Pharmaceutical Formulation
    Faridbod, Farnoush
    Larijani, Bagher
    Ganjali, Mohammad Reza
    Norouzi, Parviz
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2012, 7 (11): : 10404 - 10413
  • [35] Highly selective potentiometric determination of nitrate ions using silver bisdiethyldithiocarbamate based membrane electrodes
    Isildak, Omer
    Yildiz, Ilyas
    ELECTROCHIMICA ACTA, 2023, 459
  • [36] Ion selective PVC membrane electrode for the determination of methacycline hydrochloride in pharmaceutical formulation
    Aboul-Enein, HY
    Sun, XX
    Sun, CJ
    SENSORS, 2002, 2 (10): : 424 - 431
  • [37] PVC-Membrane Potentiometric Electrochemical Sensor Based on 2-(4-Oxopentan-2-ylideneamino)isoindoline-1,3-dione for Selective Determination of Holmium(III)
    Zamani, Hassan Ali
    E-JOURNAL OF CHEMISTRY, 2011, 8 : S97 - S104
  • [38] Determination of pethidine hydrochloride using potentiometric coated graphite and carbon paste electrodes
    Abu-Shawish, Hazem M.
    Dalou, Ayoub A.
    Abu Ghalwa, Nasser
    Khraish, Ghada I.
    Hammad, Jehad
    Basheer, Abdel-Hakem
    DRUG TESTING AND ANALYSIS, 2013, 5 (04) : 213 - 221
  • [39] Potentiometric ion-selective electrodes for determination of cyclopentolate hydrochloride and phenylephrine hydrochloride in their challenging ophthalmic formulation
    Rezk, Mamdouh R.
    Fayed, Ahmed S.
    Marzouk, Hoda M.
    Abbas, Samah S.
    JOURNAL OF SOLID STATE ELECTROCHEMISTRY, 2018, 22 (11) : 3351 - 3361
  • [40] PVC matrix membrane sensor for potentiometric determination of dodecylsulfate
    Mostafa, Gamal A. E.
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2008, 88 (06) : 435 - 446