Potentiometric Determination of Loperamide Hydrochloride by Loperamide PVC Membrane and Nano-Composite Electrodes

被引:0
作者
Faridbod, F. [1 ,2 ]
Mizani, F. [3 ]
Ganjali, M. R. [1 ,2 ]
Norouzi, P. [1 ,2 ]
机构
[1] Univ Tehran, Fac Chem, Ctr Excellence Electrochem, Tehran, Iran
[2] Univ Tehran Med Sci, Endocrinol & Metab Res Ctr, Tehran, Iran
[3] Payame Noor Univ, Dept Chem, Tehran, Iran
关键词
Loperamide; Sensor; Potentiometry; Ion-selective electrode; PVC membrane; Carbon paste; Multi-walled carbon nanotubes; CARBON-PASTE ELECTRODE; ION-SELECTIVE ELECTRODE; NANOPOROUS SILICA-GEL; ANION RECOGNITION; SCHIFFS BASE; SENSOR;
D O I
暂无
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
In this work, two new loperamide potentiometric electrodes were prepared and used for pharmaceutical analysis. In case of liquid membrane electrode, the best results were obtained from the electrode with the membrane composition of 5% ion-pair, 1% NaTPB, 30% PVC, and 64% DBP. The proposed sensor shows a Nernstian response (slope of 57.2 mV per decade) in the range of 3.0x10(-5)-1.0x10(-2) mol L-1. In case of carbon paste electrode modified by MWCNTs, calibration graph slope is about 58.5 mV per decade in the concentration range of loperamide hydrochloride 1.0x10(-5)-1.0x10(-2) mol L-1. Both sensors work well in the laboratory conditions and successfully applied in analysis of loperamide in some pharmaceutical formulations.
引用
收藏
页码:7643 / 7654
页数:12
相关论文
共 50 条
[31]   Use of organofunctionalized nanoporous silica gel to improve the lifetime of carbon paste electrode for determination of copper(II) ions [J].
Javanbakht, Mehran ;
Badiei, Alireza ;
Ganjali, Mohammad Reza ;
Norouzi, Parviz ;
Hasheminasab, Abed ;
Abdouss, Majid .
ANALYTICA CHIMICA ACTA, 2007, 601 (02) :172-182
[32]   Carbon paste electrode modified with functionalized nanoporous silica gel as a new sensor for determination of silver ion [J].
Javanbakht, Mehran ;
Ganjali, Mohammad Reza ;
Norouzi, Parviz ;
Badiei, Alireza ;
Hasheminasab, Abed ;
Abdouss, Majid .
ELECTROANALYSIS, 2007, 19 (12) :1307-1314
[33]  
LAVRIJSEN K, 1995, DRUG METAB DISPOS, V23, P354
[34]   CHARACTERIZATION OF THE ANTIDIARRHOEAL LOPERAMIDE BY GAS-CHROMATOGRAPHY MASS-SPECTROMETRY AND APPLICATION OF THE HOFMANN DEGRADATION AND COPE ELIMINATION-REACTION [J].
LEIS, HJ ;
GLEISPACH, H .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1989, 494 :324-330
[35]   HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC DETERMINATION OF LOPERAMIDE HYDROCHLORIDE IN PHARMACEUTICAL PREPARATIONS [J].
LEUNG, CP ;
AUYEUNG, CY .
JOURNAL OF CHROMATOGRAPHY, 1988, 449 (01) :341-344
[36]  
Madunic-Cacic D, 2011, INT J ELECTROCHEM SC, V6, P240
[37]  
Mersal GAM, 2011, INT J ELECTROCHEM SC, V6, P1116
[38]  
Mittal SK, 2010, INT J ELECTROCHEM SC, V5, P1984
[39]  
Oliveira AC, 2011, INT J ELECTROCHEM SC, V6, P804
[40]  
Prkic A, 2011, INT J ELECTROCHEM SC, V6, P5388