Computerized detection of colonic polyps at CT colonography on the basis of volumetric features: Pilot study

被引:184
作者
Yoshida, H
Masutani, Y
MacEneaney, P
Rubin, DT
Dachman, AH
机构
[1] Univ Chicago, Dept Radiol, Chicago, IL 60637 USA
[2] Univ Chicago, Dept Med, Chicago, IL 60637 USA
关键词
colon; CT; colon neoplasms; computers; diagnostic aid; images; analysis;
D O I
10.1148/radiol.2222010506
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To develop a computer-aided diagnosis (CAD) scheme for automated detection of colonic polyps on the basis of volumetric features and to assess its accuracy on the basis of colonoscopy, the standard. MATERIALS AND METHODS: Computed tomographic (CT) colonography was performed in patients with use of standard bowel cleansing, air insufflation, and helical scanning in supine and prone positions. The colon was extracted from volumetric data sets generated from transverse CT sections. Volumetric features characterizing polyps were computed at each point in the extracted colon. Polyps were detected by means of hysteresis thresholding and fuzzy clustering followed by a rule-based test on the basis of feature values. Locations of the detected polyps were compared with those detected at conventional colonoscopy. RESULTS: Forty-one cases were analyzed: nine cases with polyps and 32 without polyps. Each case with polyps had one polyp of clinically important size (six were 5-9 mm; three, 10 mm). Thus, there were 82 volumetric data sets, 18 included polyps. Eighty-nine percent (16 of 18) of the polyps were detected. Each of the two false-negative findings was detected in the other position; thus, 100% of polyp cases were detected, with 2.5 false-positive findings per patient. The false-positive findings were similar to those due to common perceptual errors. Most of the false-positive findings were easily distinguishable from true polyps by experienced radiologists. CONCLUSION: The CAD scheme has the potential to depict polyps with high sensitivity and an acceptable false-positive rate.
引用
收藏
页码:327 / 336
页数:10
相关论文
共 40 条
  • [1] *ACS, 1999, CANC FACTS FIG
  • [2] Optimization and FROG analysis of rule-based detection schemes using a multiobjective approach
    Anastasio, MA
    Kupinski, MA
    Nishikawa, RM
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 1998, 17 (06) : 1089 - 1093
  • [3] [Anonymous], 3 DIMENSIONAL BIOMED
  • [4] FREE-RESPONSE METHODOLOGY - ALTERNATE ANALYSIS AND A NEW OBSERVER-PERFORMANCE EXPERIMENT
    CHAKRABORTY, DP
    WINTER, LHL
    [J]. RADIOLOGY, 1990, 174 (03) : 873 - 881
  • [5] CHEN C, 1996, COMPUTER ENG SERIES
  • [6] Small simulated polyps in pig colon: Sensitivity of CT virtual colography
    Dachman, AH
    Lieberman, J
    Osnis, RB
    Chen, SYJ
    Hoffmann, KR
    Chen, CT
    Newmark, GM
    McGill, J
    [J]. RADIOLOGY, 1997, 203 (02) : 427 - 430
  • [7] Straightening the colon with curved cross sections: An approach to CT colonography
    Dave, SB
    Wang, G
    Brown, BP
    McFarland, EG
    Zhang, Z
    Vannier, MW
    [J]. ACADEMIC RADIOLOGY, 1999, 6 (07) : 398 - 410
  • [8] COSMOS - A representation scheme for 3D free-form objects
    Dorai, C
    Jain, AK
    [J]. IEEE TRANSACTIONS ON PATTERN ANALYSIS AND MACHINE INTELLIGENCE, 1997, 19 (10) : 1115 - 1130
  • [9] CT colonography: Potential pitfalls and problem-solving techniques
    Fletcher, JG
    Johnson, CD
    MacCarty, RL
    Welch, TJ
    Reed, JE
    Hara, AK
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1999, 172 (05) : 1271 - 1278
  • [10] FLETCHER JG, 1998, 27 ANN M POSTGR COUR