Control of three different continuous pharmaceutical manufacturing processes: Use of soft sensors

被引:51
作者
Rehrl, Jakob [1 ,6 ]
Karttunen, Anssi-Pekka [2 ,6 ]
Nicolai, Niels [3 ,7 ]
Hoermann, Theresa [5 ,6 ]
Horn, Martin [4 ,6 ]
Korhonen, Ossi [2 ,6 ]
Nopens, Ingmar [7 ]
De Beer, Thomas [3 ,6 ]
Khinast, Johannes G. [1 ,5 ,6 ]
机构
[1] Res Ctr Pharmaceut Engn, A-8010 Graz, Austria
[2] Univ Eastern Finland, PROMIS Ctr, Sch Pharm, FI-70211 Kuopio, Finland
[3] Univ Ghent, Lab Pharmaceut Proc Analyt Technol, B-9000 Ghent, Belgium
[4] Graz Univ Technol, Inst Automat & Control, A-8010 Graz, Austria
[5] Graz Univ Technol, Inst Proc & Particle Engn, A-8010 Graz, Austria
[6] ECCPM, A-8010 Graz, Austria
[7] Univ Ghent, Dept Math Modelling Stat & Bioinformat, B-9000 Ghent, Belgium
关键词
Continuous manufacturing; Soft sensor; Process analytical technologies; Near infrared spectroscopy; Residence time distribution; Control strategy; CONTINUOUS DRY GRANULATION; QUALITY ATTRIBUTES; LINE; PERSPECTIVES; TABLETS; PAT;
D O I
10.1016/j.ijpharm.2018.03.027
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
One major advantage of continuous pharmaceutical manufacturing over traditional batch manufacturing is the possibility of enhanced in-process control, reducing out-of-specification and waste material by appropriate discharge strategies. The decision on material discharge can be based on the measurement of active pharmaceutical ingredient (API) concentration at specific locations in the production line via process analytic technology (PAT), e.g. near-infrared (NIR) spectrometers. The implementation of the PAT instruments is associated with monetary investment and the long term operation requires techniques avoiding sensor drifts. Therefore, our paper proposes a soft sensor approach for predicting the API concentration from the feeder data. In addition, this information can be used to detect sensor drift, or serve as a replacement/supplement of specific PAT equipment. The paper presents the experimental determination of the residence time distribution of selected unit operations in three different continuous processing lines (hot melt extrusion, direct compaction, wet granulation). The mathematical models describing the soft sensor are developed and parameterized. Finally, the suggested soft sensor approach is validated on the three mentioned, different continuous processing lines, demonstrating its versatility.
引用
收藏
页码:60 / 72
页数:13
相关论文
共 28 条
  • [21] Comparing integrated continuous process ?LaVortex?? and conventional batch processes for the pharmaceutical manufacturing of acetaminophen oral dosage formulations: Challenges and pharmaceutical properties of the granular and tableted products
    Koyanagi, Keita
    Shoji, Kippei
    Ueno, Akinori
    Sasaki, Tetsuo
    Otsuka, Makoto
    INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2023, 638
  • [22] Continuous Manufacturing of High Quality Pharmaceutical Cocrystals Integrated with Process Analytical Tools for In-Line Process Control
    Moradiya, Hiren G.
    Islam, Muhammad T.
    Scoutaris, Nikolaos
    Halsey, Sheelagh A.
    Chowdhry, Babur Z.
    Douroumis, Dennis
    CRYSTAL GROWTH & DESIGN, 2016, 16 (06) : 3425 - 3434
  • [23] A hybrid NIR-soft sensor method for real time in-process control during continuous direct compression manufacturing operations
    Cogoni, Giuseppe
    Liu, Yang Angela
    Husain, Anas
    Alam, Md Anik
    Kamyar, Reza
    INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2021, 602
  • [24] A Hybrid Model Predictive Control Strategy using Neural Network Based Soft Sensors for article Processes
    Nielsen, Rasmus Fjordbak
    Gernaey, Krist, V
    Mansouri, Seyed Soheil
    30TH EUROPEAN SYMPOSIUM ON COMPUTER AIDED PROCESS ENGINEERING, PTS A-C, 2020, 48 : 1177 - 1182
  • [25] System-wide hybrid MPC-PID control of a continuous pharmaceutical tablet manufacturing process via direct compaction
    Singh, Ravendra
    Ierapetritou, Marianthi
    Ramachandran, Rohit
    EUROPEAN JOURNAL OF PHARMACEUTICS AND BIOPHARMACEUTICS, 2013, 85 (03) : 1164 - 1182
  • [26] Analytical comparison between batch and continuous direct compression processes for pharmaceutical manufacturing using an innovative UV-Vis reflectance method and chemometrics
    Macchietti, Laura
    Melucci, Dora
    Menarini, Lorenzo
    Consoli, Fabrizio
    Zappi, Alessandro
    INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2024, 656
  • [27] Quality control of multi-component, intact pharmaceutical tablets with three different near-infrared apparatuses
    Cournoyer, A.
    Simard, J. -S.
    Cartilier, L.
    Abatzoglou, N.
    PHARMACEUTICAL DEVELOPMENT AND TECHNOLOGY, 2008, 13 (05) : 333 - 343
  • [28] Off-Gas-Based Soft Sensor for Real-Time Monitoring of Biomass and Metabolism in Chinese Hamster Ovary Cell Continuous Processes in Single-Use Bioreactors
    Wallocha, Tobias
    Popp, Oliver
    PROCESSES, 2021, 9 (11)