Control of three different continuous pharmaceutical manufacturing processes: Use of soft sensors

被引:52
作者
Rehrl, Jakob [1 ,6 ]
Karttunen, Anssi-Pekka [2 ,6 ]
Nicolai, Niels [3 ,7 ]
Hoermann, Theresa [5 ,6 ]
Horn, Martin [4 ,6 ]
Korhonen, Ossi [2 ,6 ]
Nopens, Ingmar [7 ]
De Beer, Thomas [3 ,6 ]
Khinast, Johannes G. [1 ,5 ,6 ]
机构
[1] Res Ctr Pharmaceut Engn, A-8010 Graz, Austria
[2] Univ Eastern Finland, PROMIS Ctr, Sch Pharm, FI-70211 Kuopio, Finland
[3] Univ Ghent, Lab Pharmaceut Proc Analyt Technol, B-9000 Ghent, Belgium
[4] Graz Univ Technol, Inst Automat & Control, A-8010 Graz, Austria
[5] Graz Univ Technol, Inst Proc & Particle Engn, A-8010 Graz, Austria
[6] ECCPM, A-8010 Graz, Austria
[7] Univ Ghent, Dept Math Modelling Stat & Bioinformat, B-9000 Ghent, Belgium
关键词
Continuous manufacturing; Soft sensor; Process analytical technologies; Near infrared spectroscopy; Residence time distribution; Control strategy; CONTINUOUS DRY GRANULATION; QUALITY ATTRIBUTES; LINE; PERSPECTIVES; TABLETS; PAT;
D O I
10.1016/j.ijpharm.2018.03.027
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
One major advantage of continuous pharmaceutical manufacturing over traditional batch manufacturing is the possibility of enhanced in-process control, reducing out-of-specification and waste material by appropriate discharge strategies. The decision on material discharge can be based on the measurement of active pharmaceutical ingredient (API) concentration at specific locations in the production line via process analytic technology (PAT), e.g. near-infrared (NIR) spectrometers. The implementation of the PAT instruments is associated with monetary investment and the long term operation requires techniques avoiding sensor drifts. Therefore, our paper proposes a soft sensor approach for predicting the API concentration from the feeder data. In addition, this information can be used to detect sensor drift, or serve as a replacement/supplement of specific PAT equipment. The paper presents the experimental determination of the residence time distribution of selected unit operations in three different continuous processing lines (hot melt extrusion, direct compaction, wet granulation). The mathematical models describing the soft sensor are developed and parameterized. Finally, the suggested soft sensor approach is validated on the three mentioned, different continuous processing lines, demonstrating its versatility.
引用
收藏
页码:60 / 72
页数:13
相关论文
共 27 条
[1]   Strategic funding priorities in the pharmaceutical sciences allied to Quality by Design (QbD) and Process Analytical Technology (PAT) [J].
Aksu, Buket ;
De Beer, Thomas ;
Folestad, Staffan ;
Ketolainen, Jarkko ;
Linden, Hans ;
Lopes, Joao Almeida ;
de Matas, Marcel ;
Oostra, Wim ;
Rantanen, Jukka ;
Weimer, Marco .
EUROPEAN JOURNAL OF PHARMACEUTICAL SCIENCES, 2012, 47 (02) :402-405
[2]  
[Anonymous], 2004, Food and Drug Administration Guidance for industry PATa framework for innovative pharmaceutical development, manufacturing and quality Assurance
[3]   An integrated approach for dynamic flowsheet modeling and sensitivity analysis of a continuous tablet manufacturing process [J].
Boukouvala, Fani ;
Niotis, Vasilios ;
Ramachandran, Rohit ;
Muzzio, Fernando J. ;
Ierapetritou, Marianthi G. .
COMPUTERS & CHEMICAL ENGINEERING, 2012, 42 :30-47
[4]  
Chatterjee S., 2012, IFPAC Annual Meeting
[5]   Using Residence Time Distributions (RTDs) to Address the Traceability of Raw Materials in Continuous Pharmaceutical Manufacturing [J].
Engisch, William ;
Muzzio, Fernando .
JOURNAL OF PHARMACEUTICAL INNOVATION, 2016, 11 (01) :64-81
[6]  
Fogler H.S., 2016, Elements of Chemical Reaction Engineering, VFifth
[7]   Blend uniformity evaluation during continuous mixing in a twin screw granulator by in-line NIR using a moving F-test [J].
Fonteyne, Margot ;
Vercruysse, Jurgen ;
De Leersnyder, Fien ;
Besseling, Rut ;
Gerich, Ad ;
Oostra, Wim ;
Remon, Jean Paul ;
Vervaet, Chris ;
De Beer, Thomas .
ANALYTICA CHIMICA ACTA, 2016, 935 :213-223
[8]   Real-time assessment of critical quality attributes of a continuous granulation process [J].
Fonteyne, Margot ;
Vercruysse, Jurgen ;
Cordoba Diaz, Damian ;
Gildemyn, Delphine ;
Vervaet, Chris ;
Remon, Jean Paul ;
De Beer, Thomas .
PHARMACEUTICAL DEVELOPMENT AND TECHNOLOGY, 2013, 18 (01) :85-97
[9]   Prediction of quality attributes of continuously produced granules using complementary pat tools [J].
Fonteyne, Margot ;
Soares, Sandra ;
Vercruysse, Jurgen ;
Peeters, Elisabeth ;
Burggraeve, Anneleen ;
Vervaet, Chris ;
Remon, Jean Paul ;
Sandler, Niklas ;
De Beer, Thomas .
EUROPEAN JOURNAL OF PHARMACEUTICS AND BIOPHARMACEUTICS, 2012, 82 (02) :429-436
[10]  
Franklin G. F., 1997, DIGITAL CONTROL DYNA