Application of screen-printed microband biosensors to end-point measurements of glucose and cell numbers in HepG2 cell culture

被引:29
作者
Pemberton, R. M. [1 ]
Xu, J. [2 ]
Pittson, R.
Biddle, N.
Drago, G. A.
Jackson, S. K. [2 ]
Hart, J. P. [1 ]
机构
[1] Univ W England, Fac Hlth & Life Sci, Ctr Analyt Mat & Sensors Sci, Bristol BS16 1QY, Avon, England
[2] Univ W England, Fac Hlth & Life Sci, Ctr Biomed Res, Bristol BS16 1QY, Avon, England
关键词
Glucose biosensor; Microband electrode; Cell culture; HepG2; cells; Glucose metabolism; CARBON INK;
D O I
10.1016/j.ab.2008.10.037
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Microband glucose biosensors were produced by insulating and sectioning through a screen-printed, water-based carbon electrode containing cobalt phthalocyanine redox mediator and glucose oxidase enzyme. Under quiescent conditions at 37 degrees C, at an operating potential of +0.4 V, they produced an amperometric response to glucose in buffer solutions with a sensitivity of 26.4 nA/mM and a linear range of 0.45 to 9.0 mM. An optimal pH value of 8.5 was obtained under these conditions, and a value for activation energy of 40.55 kJ mol(-1) was calculated. In culture medium (pH 7.3), a sensitivity of 13 nA/mM was obtained and the response was linear up to 5 mM with a detection limit of 0.5 mM. The working concentration was up to 20 mM glucose with a precision of 11.3% for replicate biosensors (n = 4). The Microband biosensors were applied to determine end-point glucose concentrations in Culture medium by monitoring steady-state current responses 400 s after transfer of the biosensors into different sample solutions. In conjunction with Cultures of HepG2 (human Caucasian hepatocyte carcinoma) cells, current responses obtained in 24-h supernatants showed an inverse correlation (R-2 = 0.98) with cell number, indicating that the biosensors were applicable for monitoring glucose metabolism by cells and of quantifying cell number. Glucose concentrations determined using the biosensor assay were in good agreement, for concentrations Lip to 20 mM, with those determined spectrophotometrically (R-2 = 0.99). This method of end-point glucose determination was used to provide an estimated rate of glucose uptake for HepG2 cells of 7.9 nmol/(10(6) cells min) based on a 24-h period in Culture. (C) 2008 Elsevier Inc. All rights reserved.
引用
收藏
页码:334 / 341
页数:8
相关论文
共 18 条
  • [1] A novel, disposable, screen-printed amperometric biosensor for glucose in serum fabricated using a water-based carbon ink
    Crouch, E
    Cowell, DC
    Hoskins, S
    Pittson, RW
    Hart, JP
    [J]. BIOSENSORS & BIOELECTRONICS, 2005, 21 (05) : 712 - 718
  • [2] Amperometric, screen-printed, glucose biosensor for analysis of human plasma samples using a biocomposite water-based carbon ink incorporating glucose oxidase
    Crouch, E
    Cowell, DC
    Hoskins, S
    Pittson, RW
    Hart, JP
    [J]. ANALYTICAL BIOCHEMISTRY, 2005, 347 (01) : 17 - 23
  • [3] *DUNN LAB, GLUCCELL GLUC MON SY
  • [4] The CD28 signaling pathway regulates glucose metabolism
    Frauwirth, KA
    Riley, JL
    Harris, MH
    Parry, RV
    Rathmell, JC
    Plas, DR
    Elstrom, RL
    June, CH
    Thompson, CB
    [J]. IMMUNITY, 2002, 16 (06) : 769 - 777
  • [5] PROTOTYPE, SOLID-PHASE, GLUCOSE BIOSENSOR
    GILMARTIN, MAT
    HART, JP
    PATTON, DT
    [J]. ANALYST, 1995, 120 (07) : 1973 - 1981
  • [6] Hart JP, 2007, COMPREHENSIVE ANAL C, V49, P495
  • [7] DISPOSABLE ELECTROCHEMICAL BIOSENSORS
    HILDITCH, PI
    GREEN, MJ
    [J]. ANALYST, 1991, 116 (12) : 1217 - 1220
  • [8] Hochachka P.W., 1984, Biochemical Adaptation
  • [9] Identification of metabolic fluxes in hepatic cells from transient 13C-labeling experiments:: Part I.: Experimental observations
    Hofmann, Ute
    Maier, Klaus
    Nicbel, Anja
    Vacun, Gabriele
    Reuss, Matthias
    Mauch, Klaus
    [J]. BIOTECHNOLOGY AND BIOENGINEERING, 2008, 100 (02) : 344 - 354
  • [10] MATHEWS DR, 1987, LANCET, V1, P778